• Title/Summary/Keyword: Pressure resistance

Search Result 2,182, Processing Time 0.03 seconds

Simulation of Neutron irradiation Corrosion of Zr-4 Alloy Inside Water Pressure reactors by Ion Bombardment

  • Bai, X.D.;Wang, S.G.;Xu, J.;Chen, H.M.;Fan, Y.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.96-109
    • /
    • 1997
  • In order to simulate the corrosion behavior of Zr-4 alloy in pressurized water reactors it was implanted (or bombarded) with 190ke V $Zr^+\; and \;Ar^+$ ions at liquid nitrogen temperature and room temperature respectively up to a dose of $5times10^{15} \sim 8\times10^{16} \textrm{ions/cm}^2$ The oxidation behavior and electrochemical vehavior were studied on implanted and unimplanted samples. The oxidation kinetics of the experimental samples were measured in pure oxygen at 923K and 133.3Pa. The corrosion parameters were measured by anodic polarization methods using a princeton Applied Research Model 350 corrosion measurement system. Auger Electron Spectroscopy (AES) and X-ray Photoelectric Spectroscopy (XPS) were employed to investigate the distribution and the ion valence of oxygen and zirconium ions inside the oxide films before and after implantation. it was found tat: 1) the $Zr^+$ ion implantation (or bombardment) enhanced the oxidation of Zircaloy-4 and resulted in that the oxidation weight gain of the samples at a dose of $8times10^{16}\textrm{ions/cm}^2$ was 4 times greater than that of the unimplantation ones;2) the valence of zirconium ion in the oxide films was classified as $Zr^0,Zr^+,Zr^{2+},Zr^{3+}\; and \;Zr^{4+}$ and the higher vlence of zirconium ion increased after the bombardment ; 3) the anodic passivation current density is about 2 ~ 3 times that of the unimplanted samples; 4) the implantation damage function of the effect of ion implantation on corrosion resistance of Zr-4 alloy was established.

  • PDF

An Introduction Of Abdominal Palpation Signs In Japanese Oriental Medicine -A New Approach To The Practice Of Abdominal Palpation In Korean Oriental Medicine- (한방(漢方)의 복진법(腹診法)에 관(關)하여 -한의학(韓醫學)에서의 복진법(腹診法) 도입(導入)에 대한 접근시도(接近試圖)-)

  • Joh, Ki-Ho;Toshiaki, Kita;Katsutoshi, Terasawa;Moon, Sang-Kwan;Ko, Chang-Nam;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.86-96
    • /
    • 1997
  • We examined clinical and reseach data about abdominal palpation conducted in japanese oriental medicine from the early stages of its medical history to the latest research, so as to introduce it into korean oriental medicine. That is to say, we studied clinical significance and suitable oriental medicine prescription about following : sweat and moistness of abdominal skin ; temperature of abdominal skin ; palpation and visible peristaltic movement ; meteorism ; tonus of the whole rectus abdominis muscle ; local tonus of parts rectus abdominis muscle ; palpitation of abdominal aorta ; resistance tender on pressure in epigastric region, subcostal region, umbilical region, lower abdomen, para-umbilical region, cecal region, sigmoid region and inguinal region ; sound of fluctuating liquid in the epigastric region. The result was that abdominal palpation was an immediately applicable method of clinical diagnosis in oriental medicine, and is being proven by western medicine methodology today. Therefore we suggest that korean oriental medicine would advance greatly if abdominal palpation were applied.

  • PDF

Development of Large-Scale Rice Polisher with Double Polishing Stages (2단계 연마방식 대형 연미기의 개발)

  • 정종훈
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.309-316
    • /
    • 1999
  • This study was conducted to develop a large-scale rice polisher with double polishing stages for producing clean rice with high quality in rice processing complexs. The performance of the developed rice polisher was evaluated and improved. The results obtained from this study were as followings : 1. A large-scale rice polisher with double polishing stages was developed, which consisted of two polishing chambers(polishing part I and II), two spraying parts, a feeding part, power of 37kW, control panel, etc. Especially, the purpose of polishing part Iwere to uniformly mix white rice sprayed with water and to remove bran particles from the rice. the roller surface of the polishing part I was coated with chromium. 2. The capacity of the developed rice polisher was 4t/h. The broken rice rate of the polisher was less than 0.2%, compared with about 1% of others. 3. The whiteness increment of the developed polisher was 2.6~3.0% compared with about 2.3~2.5% of others. 4. The energy consumption of the developed polisher was 0.5kWh/100kg. 5. The developed polisher was improved with the angle change of screen slot of the polishing chamber I. The broken rice rate was reduced from about 0.5% to about 0.2% as the max. internal pressure of the polishing chamber II decreased by 0.4kg/$\textrm{cm}^2$ due to the increase of resistance in the polishing chamber I. The whiteness of the polisher showed more than 38~39. 6. The developed rice polisher showed high performance, compared with other domestic and foreign polishers.

  • PDF

The Characteristics of Diamond-like Carbon Films Deposited by Low Frequency(60Hz) Plasma CVD at Room Temperature for Optical lens (광학렌즈를 위한 저주파(60Hz) 플라즈마 CVD로 실온에서 제작한 다이아몬드성 탄소 박막의 특성)

  • Kang, Sung Soo;Lee, Won Jin;Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.23-28
    • /
    • 1996
  • Hydrogenated amorphous carbon films were fabricated by low frequency(60Hz) Plasma enhanced Chemical vapor deposition(LF-PECVD) at room temperature. The LF_PECVD has a couple of advantages as follows: cheap, and the employment of low power density makes the damage of samples small. The a-C:H films deposited in this work were highly transparent(99%), highly resistance(109-1011${\Omega}$-cm), and very uniform. The samples were deposited by the decomposition of CH4 and H2 mixing gas in the pressure rate range of 1% to 30%. The deposition rates, optical gap, and hydrogen contents are increased with CH4 contents.

  • PDF

Significance of the Preoperative Examinations in Predicting the Defect Size of Ventricular Septal Defect (심실중격결손의 크기 측정에 있어서 술전 검사의 의의)

  • Kim, Keun;Chang, Bong-Hyun;Lee, Jong-Tae;Kim, Kyu-Tae;Lee, Sang-Bum
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.289-295
    • /
    • 1992
  • We evaluated the correlationship between the predicted defect size at preoperative examination and the actual defect size at operation room, by examining 69 cases of ventricular septal defect operated at the deparment of Thoracic and Cardiovascular surgery, Kyungpook University Hospital from January 1988 to December 1990. We excluded cases associated with other cardiac anomalies. Of the 69 cases, 39 are male and 30 female, forming 1.3:1 sex ratio in males favor. Their age range from 6 months to 16 year, and 4.3 on the average Their body weights are from 6 to 45kg and 15 on the average. According to Soto`s classification, perimembranous type costitutes 42 cases[61%], doubly committed subarterial type 23 cases[33%], and muscular type 4 cases[6%]. The average diameter of defect size is 8.0$\pm$3.5mm measured in 2D-echocardiogram, 5.6$\pm$3.4mm in angiogram, and 7.4$\pm$4.4mm in operative field. There is statistically significant correlation between the size from 2D-echocardiogram and actual defect size[p=0.001], and no significant difference between the two. Especially in the cases without anurysmal formation, they are nearly the same. Cardiothoracic ratio, pulmonary to systemic flow ratio, pressure ratio and resistance ratio also have statistically significant correlation. Main pumonary artery to descending aorta diameter ratio is correlated with the actual defect size. There is statistically significant correlation between the size from angiogram and actual defect size with some difference.

  • PDF

Sputtered Al-Doped ZnO Layers for Cu2ZnSnS4 Thin Film Solar Cells

  • Lee, Kee Doo;Oh, Lee Seul;Seo, Se-Won;Kim, Dong Hwan;Kim, Jin Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.688-688
    • /
    • 2013
  • Al-doped ZnO (AZO) thin films have attracted a lot of attention as a cheap transparent conducting oxide (TCO) material that can replace the expensive Sn-doped In2O3. In particular, AZO thin films are widely used as a window layer of chalcogenide-based thin film solar cells such as Cu(In,Ga)Se2 and Cu2ZnSnS4 (CZTS). Mostly important requirements for the window layer material of the thin film solar cells are the high transparency and the low sheet resistance, because they influence the light absorption by the activelayer and the electron collection from the active layer, respectively. In this study, we prepared the AZO thin films by RF magnetron sputtering using a ZnO/Al2O3 (98:2wt%) ceramic target, and the effect of the sputtering condition such as the working pressure, RF power, and the working distance on the optical, electrical, and crystallographic properties of the AZO thin films was investigated. The AZO thin films with optimized properties were used as a window layer of CZTS thin film solar cells. The CZTS active layers were prepared by the electrochemical deposition and the subsequent sulfurization process, which is also one of the cost-effective synthetic approaches. In addition, the solar cell properties of the CZTS thin film solar cells, such as the photocurrent density-voltage (J-V) characteristics and the external quantum efficiency (EQE) were investigated.

  • PDF

Characterization of $ET_B$ Receptor-mediated Relaxation in Precontracted Mesenteric Artery from Streptozotocin-induced Diabetic Rats

  • Eom, Yang-Ki;Kim, Koan-Hoi;Rhim, Byung-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.5
    • /
    • pp.305-314
    • /
    • 2005
  • Diabetes mellitus is associated with vascular complications, including an impairment of vascular function and alterations in the reactivity of blood vessels to vasoactive substances in various vasculature. In the present study, the authors have observed endothelin-B ($ET_B$) receptor agonist-induced relaxation in precontracted mesenteric arterial segments from streptozotocin (STZ)-induced diabetic rats, which was not shown from control rats or in other arterial segments from diabetic rats. Accordingly, the goal of this study was to investigate in what way STZ-induced diabetes altered reactivity of the mesenteric arterial bed and to examine the causal relaxation, if any, between this $ET_B$ receptor-mediated relaxation and endothelial paracrine function, especially nitric oxide (NO) production. The relaxation induced by $ET_B$ agonists was not observed in mesenteric arteries without endothelium. The relaxation to $ET_B$ agonists was completely abolished by pretreatment with BQ788, but not by BQ610. $N_{\omega}-nitro-L-arginine$ methyl ester and soluble guanylate cyclase inhibitors, methylene blue or LY83583 significantly attenuated the relaxant responses to $ET_B$ agonists, respectively. When the expression of eNOS and iNOS was evaluated on agarose gel stained with ethidium bromide, the expression of eNOS mRNA in diabetic rats was significantly decreased, but the expression of iNOS was increased compared with control rats. Furthermore, the iNOS-like immunostaining was densely detected in the endothelium and slightly in the arterial smooth muscle of diabetic rats, but not in control rats. These observations suggest that $ET_B$ receptor may not play a role in maintaining mesenteric vascular tone in normal situation. However, the alterations in $ET_B$ receptor sensitivity were found in diabetic rats and lead to the $ET_B$ agonist-induced vasorelaxation, which is closely related to NO production. In the state of increased vascular resistance of diabetic mesenteric vascular bed, enhanced NO production by activation of iNOS could lead to compensatory vasorelaxation to modulate adequate perfusion pressure to splanchnic area.

A Study on the Development of Reinforced Earth wall by Geotextile (토목섬유를 이용한 보강토옹벽의 개발)

  • 도덕현;유능환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.2
    • /
    • pp.63-73
    • /
    • 1986
  • The model was developed by applying the principles of Bacot and Vidal to measure the behavior of deformation of the reinforced earth wall, and various tasts were performed by using the plastic fabric filter and the galvanized steel plate as a strip. The results obtained are as follows; 1. When the reinforced earth wall is deformed by the load, the strip is completely reinforced by the backfill materials and changed to the rigid block state, under the state of failure which permits sliding only, the next theoretical equation is formed. (H/L) . tan$\theta$ [cosO-sinOtanO] =2sinO[tan($\theta$ +0) +tanO] 2.The degree of the mutual reinforcement of the backfill material and the strip depend on the physical characteristics of the each material especially the angle of shearing resistance of the backfill material is desirable over 20$^{\circ}$ and, if it is over 400, its function could be a maximum. 3.The distribution of the maximum tensile strain of the reinforcement is changing with the height of reinforced earth wall, and when the height from bottom of the reinforced earth wall is 1.85 to 3. 35m, the maximum tensile strain appears at 2m from the skin element. The maximum tensile strain is increased by the depth of the reinforced earth wall from surface, and increased with the lapse of time after construction. 4.The failure surface of the reinforced earth wall by the concrete skin was about 60$^{\circ}$and the failure behavior of the reinforced earth wall in which the fabric filter was buried was slow, and so the pore pressure could be decreased. 5.It is possible to construct the fabric retained earth wall by the plastic fabric filter only. And the reinforcing effect between the steel plate and the plastic fabric filter is not largely different. however, in the aspect of the economic durability, the plastic fabric filter is more advantageous. 6.The reinforcing action mainly depends on the width and the length of the reinforcing materials, if possible, the full width is advantageous to enlarge the contact area with backfill. but considering the economic aspect, it is neccessary to develop the method controlling the space of the strip.

  • PDF

Hypoxic pulmonary vasoconstriction and vascular contractility in monocrotaline-induced pulmonary arterial hypertensive rats

  • Kim, Hae Jin;Yoo, Hae Young
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.6
    • /
    • pp.641-647
    • /
    • 2016
  • Pulmonary arterial hypertension (PAH) is a progressive disease characterized by vascular remodeling of pulmonary arteries (PAs) and increased vascular resistance in the lung. Monocrotaline (MCT), a toxic alkaloid, is widely used for developing rat models of PAH caused by injury to pulmonary endothelial cells; however, characteristics of vascular functions in MCT-induced PAH vary and are not fully understood. Here, we investigated hypoxic pulmonary vasoconstriction (HPV) responses and effects of various vasoconstrictors with isolated/perfused lungs of MCT-induced PAH (PAH-MCT) rats. Using hematoxylin and eosin staining, we confirmed vascular remodeling (i.e., medial thickening of PA) and right ventricle hypertrophy in PAH-MCT rats. The basal pulmonary arterial pressure (PAP) and PAP increase by a raised flow rate (40 mL/min) were higher in the PAH-MCT than in the control rats. In addition, both high $K^+$ (40 mM KCl)- and angiotensin II-induced PAP increases were higher in the PAH-MCT than in the control rats. Surprisingly, application of a nitric oxide synthase inhibitor, L-$N^G$-Nitroarginine methyl ester (L-NAME), induced a marked PAP increase in the PAH-MCT rats, suggesting that endothelial functions were recovered in the three-week PAH-MCT rats. In addition, the medial thickening of the PA was similar to that in chronic hypoxia-induced PAH (PAH-CH) rats. However, the HPV response (i.e., PAP increased by acute hypoxia) was not affected in the MCT rats, whereas HPV disappeared in the PAH-CH rats. These results showed that vascular contractility and HPV remain robust in the MCT-induced PAH rat model with vascular remodeling.

UF pretreatment at elevated temperature within the scheme of hybrid desalination: Performance and environmental impact

  • Agashichev, Sergey;Kumar, Jayesh
    • Membrane and Water Treatment
    • /
    • v.8 no.3
    • /
    • pp.279-292
    • /
    • 2017
  • This study was aimed at ultrafiltration (UF) as a pretreatment before reverse osmosis (RO) within the scheme of hybrid reverse osmosis-multistage flush (RO-MSF) desalination. Seawater at elevated temperature (after MSF heat-exchangers) was used as a feed in this process. The pretreatment system was represented as a set of functionally-linked technological segments such as: UF filtration, backwashing, chemical- enhanced backwashing, cleaning, waste disposal, etc. The process represents the sequences of operating cycles. The cycle, in turn, consists of the following unit operations: filtration, backwashing and chemical-enhanced backwashing (CEB). Quantitative assessment was based on the following indicators: normalized permeability, transmembrane pressure, specific energy and water consumption, specific waste generation. UF pre-treatment is accompanied by the following waste streams: $W1=1.19{\times}10$ power of $-2m^3$ (disposed NaOCl with 0.0044% wt.)/$m^3$ (filtrate); $W2=5.95{\times}10$ power of $-3m^3$ (disposed $H_2SO_4$ with 0.052% wt.)/$m^3$(filtrate); $W3=7.26{\times}10$ power of $-2m^3$ (disposed sea water)/$m^3$ (filtrate). Specific energy consumption is $1.11{\times}10$ power of $-1kWh/m^3$ (filtrate). The indicators evaluated over the cycles with conventional (non-chemical) backwashing were compared with the cycles accompanied by CEB. A positive impact of CEB on performance indicators was demonstrated namely: normalized UF resistance remains unchanged within the regime accompanied by CEB, whereas the lack of CEB results in 30% of its growth. Those quantitative indicators can be incorporated into the target function for solving different optimization problems. They can be used in the software for optimisation of operating regimes or in the synthesis of optimal flow- diagram. The cycle characteristics, process parameters and water quality data are attached.