• Title/Summary/Keyword: Pressure regulator

Search Result 147, Processing Time 0.032 seconds

MODELING AND SIMULATION FOR GAS PIPELINE SYSTEMS

  • Yoshida, Makoto;Kawato, Takashi;Fujita, Toshinori;Kawashima, Kenji;Kagawa, Toshiharu
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.335-339
    • /
    • 2001
  • City gas is one of the most important necessities of daily city life and social infrastructures. City gas is delivered to every user through a pipeline network. The gas pressure in the pipeline is regulated by gas regulator. In the pressure control system, characteristics of gas pipeline is as important as characteristics of regulator. There are many reports about the transfer function model of the fluid pipeline. But suitable model about the gas transmission pipeline is not known. In this paper, as the transfer function model of the gas pipeline, new model considering the heat transfer between pipe wall and gas and temperature change of gas is proposed. To evaluate this model, frequency response tests are used. As the result, the proposed model shows a better agreement when compared with the experimental result than conventional models. The results show the effectiveness of the model.

  • PDF

Design on Hydraulic Regulator in Liquid Rocket Engine (액체로켓엔진용 유압식 레귤레이터 설계)

  • Kim, Yun-Sang;Han, Poong-Gyoo;Kim, Young-Soo;B.N., Hahin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.174-177
    • /
    • 2007
  • In this work, we researched static and dynamic characteristics concern to hydraulic regulator control process and parameter setting, which is used on liquid rocket engine regulation. The hydraulic regulator of 8K14 "SCUD" 9D21 engine is analyzed and on the basis of the developed mathematical modeling the analysis of response time and certification on automatic control accuracy is carried out. In this process, we find out specific design configuration of needle valve flow section that effects on pressure regulation performance.

  • PDF

Analysis of Line Regulator Valve and Ratio Control Valve Considering CVT Shift Dynamics (CVT 변속 동역학을 고려한 라인 레귤레이터 및 변속비 제어 밸브의 응답 특성 해석)

  • 정근수;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.81-91
    • /
    • 2000
  • Dynamic models of line regulator valve(LRV) and ratio control valve (RCV) are obtained for an electronic controlled CVT. LRV and RCV are operated by variable force solenoid(VFS). Considering the CVT shift dynamics, oil pump's efficiency and saturation characteristics of VFS, simulations are performed and compared with test results. Simulation results are in good agreement with the experiments, which shows the validity of the dynamic models of LRV and RCV obtained. In addition, the effects of the orifice size in the exhaust port of RCV are investigated. Simulation results show that as the orifice size decreases, the residual pressure in the primary actuator increases which insures the large torque transmission capacity, meanwhile the duration time for the downshift increases.

  • PDF

A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip (랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법)

  • Han, Su-Dong;Kim, Guk-Bae;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

Analysis of Heat Transfer considering thickness of Thermal Barrier Coating (열차폐 코팅 두께를 고려한 핀틀의 열전달 해석)

  • Jang, Han Na;Lee, Ji Hoon;Kwak, Jae Su;Cho, Jin Yeon;Kim, Jae Hoon;Ko, JunBok;Heo, Jun-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.392-394
    • /
    • 2017
  • In this study, the surface heat transfer coefficient of the 3D model of a thruster regulator in the high temperature and high pressure environment was estimated using the CFD. The thermal barrier coating (TBC) on the surface of the thruster regulator was modeled and the effect of the thickness of the TBC on the temperature of the thruster regulator was investigated. The thickness of the TBC was varied from $100{\mu}m$ to $500{\mu}m$. Results showed that the temperature of the surface and the inside the thruster regulator was lower for the thicker TBS case.

  • PDF

XBRL Adoption Process in Malaysia Using Diffusion of Innovation Theory

  • ILIAS, Azleen;GHANI, Erlane K.;AZHAR, Zubir
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.2
    • /
    • pp.263-271
    • /
    • 2021
  • The study examined the XBRL adoption process of Malaysian Business Reporting System (MBRS) by utilizing Everett Rogers' Diffusion of Innovation (DOI) theory. The study focused on the three phases, namely, knowledge gathering and persuasion phase, decision-making phase, and implementation phase of XBRL adoption process gathered from a government agency in Malaysia. This study employs a qualitative case study that incorporates semi-structured interviews with four members of the regulator. The results reveal that the regulator has realized the advantages, management support, and need to skills development in phase one. On the other hand, in phase two, it finds the way the regulator makes decision related to XBRL taxonomy and submission template, platform, tools and software. Through phase three, the regulator is concerned with the complexity of XBRL taxonomy, resources, external support, promotion, stakeholder involvement, limited trading pressure, critical mass, and professional bodies. The factors from each phase suggest an in-depth understanding on the experience of XBRL through the development of MBRS that provides a success story to the other government agencies and regulators in Malaysia. This study provides several insights on the factors that could contribute to the adoption of XBRL and the Diffusion of Innovation theory adoption process.

A Study on the Performance Characteristics of Low Pressure Hydraulic Circuit of Common Rail System (커먼레일 시스템용 저압 유압회로의 성능특성에 관한 연구)

  • Lee, Choon-Tae
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.51-57
    • /
    • 2014
  • High pressure common rail injection technology has revolutionized the diesel industry. Over the last decade it has allowed engine builders to run higher injection pressures as much as above 1,300bar in order to increase engine efficiency, while reducing emissions. This common rail system has low pressure circuit which is consist of low pressure pump, cascade overflow valve and flow metering unit. The low pressure pump's purpose is to feed fuel oil to the high pressure pump. The cascade overflow valve keeps pressure in front of the metering unit constant and provides lubrication for the high pressure pump. The metering unit, known as the MPROP or fuel pressure regulator, regulates the maximum flow rate delivers to the rail. In this paper, we have investigated the performance characteristics of each components and total low pressure circuit of common rail system.

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station (II) - Flow Analysis and Required Effective Discharge Area of Safety Valve - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석 (II) - 안전밸브 유동 해석 및 필요분출면적 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.105-109
    • /
    • 2008
  • A safety valve has a valve mechanism for the automatic release of gas from piping system when the pressure exceeds preset limit cause of a defect of a pressure regulator, condensation of water in a pipe. Therefore, for the safety of pressure regulating station, it is essential to study the flow regime and characteristics of safety valve. This article presents the numerical analysis on the flow analysis, the ejection capacity and required effective discharge area of the safety valve that is established in pressure regulating station. Then, the results are compared and analyzed with domestic and foreign regulations such as API(America Petroleum Institute), EN(European Standard), and NF(Norme Francise). Moreover, the installation number of safety valve is considered by using domestic and foreign regulations and maximum reguired effective discharge area of safety valve.

  • PDF