배관내 압력변동 신호를 이용한 유량 추정 방법 연구 (A Study on Flow Rate Estimation Using Pressure Fluctuation Signals in Pipe)

  • 이정한;장대식;박진호
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.155-162
    • /
    • 2023
  • In nuclear power plants, the flow rate information is a major indicator of the performance of rotating equipment such as pumps, and is a very important one required for facility operation and maintenance. To measure a flow rate, various types of methods have been developed and used. Among them, the differential pressure type using orifice and the direct doppler type using ultrasonic waves are the most commonly used. However, these flow rate measurement methods have limitations in installation, conditions and status of the measuring part, etc. To solve this problem, we have studied a new technique for measuring flow rate from scratch. In this paper, we have devised a technique to estimate the flow rate using an average moving velocity of large-scale eddy in turbulence that occurs in the piping flow field. The velocity of the large-scale eddy can be measured using the pressure fluctuation signals on the inner surface of the pipe. To estimate the flow rate, at first a cross-correlation function is applied to the two pressure fluctuation signals located at different positions in the down stream for calculating the time delay between the moving eddies. In order to validate the proposed flow rate estimation method, CFD analyses for the internal turbulence flow in pipe are conducted with a fixed flow condition, where the pressure fluctuation signals on the pipe inner surface are simulated. And then the average flow velocity of the large scale eddy is to be estimated. The estimated flow velocity is turned out to be similar to the fixed (known) flow rate.

A Numerical Modeling of Thawing Rate for Frozen Pork using High Pressure Assisted Thawing Technique

  • Ryu, Hyun-Sik;Park, Sung-Hee;Min, Sang-Gi
    • 한국축산식품학회:학술대회논문집
    • /
    • 한국축산식품학회 2004년도 제34차 추계 국제 학술대회
    • /
    • pp.310-315
    • /
    • 2004
  • The objective of this study was to provide the optimum thawing condition under different level of high pressure(50, 100, 150 and 200 MPa) using high pressure assisted technique which can improve the quality of frozen and thawed pork. The calculated thawing rate from the results depending on the high pressure showed the strong trend of increased thawing rate under pressurized condition(P<0.05). And then, the numerical modeling was executed to predict the thawing rate influenced by the pressure level using exponential regression, LnY=0.70623 + 0.00433 ${\cdot}$ P ($R^2=0.9985$), and it was fairly fit for the functional relation between the thawing rate(Y) and pressure(P) with comparatively high coefficient, $R^2$ of determination.

  • PDF

배기 압력 상승률에 의한 실화 검출 (The Misfire Detection by the Exhaust Pressure Ascent Rate)

  • 김세웅;최미호;심국상
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.1-7
    • /
    • 2003
  • This paper proposes a method to detect misfired cylinders by the exhaust pressure ascent rate. The misfire is generated by faults of electric system or faults of fuel delivery system. It is one of the abnormal combustions. Therefore, it increases the unburned hydrocarbon and the carbon monoxide and affects a bad influence to the 3-way catalyst. The misfire causes to decrease the power of the engine and increase the consumption of the fuel. Early detection and correction of the misfired cylinders can prevent these unusual phenomena. The misfired cylinders can be detected by the comparison of exhaust pressure ascent rate during each cycle. The exhaust pressure ascent rate is defined as pressure rise per time. Our experimental results showed that the proposed method is effective in the detection of the misfired cylinders on a gasoline engine regardless loads and revolutions of the engine.

초고압에서 고체 추진제의 연소속도 특성 (Burning Rate Characteristics of Solid Propellant at Extremely High Pressure)

  • 성홍계;유지창
    • 한국추진공학회지
    • /
    • 제10권3호
    • /
    • pp.60-66
    • /
    • 2006
  • 초고압(10000-20000 psia)에서 연소하는 추진제의 연소속도 특성을 연구하였다. closed bomb의 시편 시험을 통하여 약 4000 psia를 분기점으로 연소속도가 급격히 증가되며, 압력지수는 0.4에서 약 0.8로 2배 이상 증가된다. 실제 모터의 연소시험에서 압력 상승률이 일반 압력(2000 psia)에서 작동하는 모터보다 300배 이상이 되며, 연소속도는 압력 상승률에 매우 민감하며 5-50배의 연소속도 증가를 나타낸다. 본 연구에서 제시된 압력 상승률을 감안한 연소속도 모델의 결과는 초고압에서 작동하는 실제의 다양한 조건에서 실시된 시험 데이터와 일치하는 결과를 제시하였다.

Effect of Mixture Flow Rate on Emission Characteristics of Laminar Premixed CH4/Air Flame with Changing Combustor Pressure

  • Ma, Hai-quan;Song, Jae-hyeok;Kang, Ki-joong;Choi, Gyung-min;Kim, Duck-jool
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.269-271
    • /
    • 2012
  • To investigate emission characteristics of laminar premixed CH4/air flame, combustion experiments were conducted at three flow rates (5.3L/min, 10.6L/min, 15.5L/min) with changing the combustor pressure(-30Kpa-30Kpa). It was found that with increasing flow rate, NOx emission increased in high pressure condition, while decreased in low pressure condition; and the emission of CO decreased with increasing flow rate. For the influence of pressure, emission of NOx increased with increasing pressure regardless of flow rates, while CO emission decreased on the contrary.

  • PDF

지시적 심상요법이 혈압과 맥박에 미치는 효과 - 간호대학생을 대상으로 - (The Effect of Guided Imagery on Blood Pressure and Pulse Rate - In Nursing Students -)

  • 최은옥;이동숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제5권2호
    • /
    • pp.31-39
    • /
    • 2003
  • The purpose of this study was to test the effect of guided imagery on blood pressure and pulse rate. The subjects were thirty-nine nursing students in I university located in Busan, Korea To enhance the effect of treatment, they were trained getting themselves absorbed in guided imagery on three different occasions before the study. Actually in the study, the subjects were given instruction in Mason's guided imagery for 19 minutes and 58 seconds. Blood pressure and pulse rate were measured before and after guided imagery application. The data were analyzed through paired t-test. The Results were as follows : 1) There was a significant decrease in systolic blood pressure after the use of guided imagery. 2) There was no significant decrease in diastolic blood pressure after the use of guided imagery. 3) There was a significant decrease in pulse rate after the use of guided imagery. These results indicate that guided imagery is a helpful technique for decreasing blood pressure and pulse rate, which are increased in stress condition.

  • PDF

정전형여과집진방식에서 여과특성에 관한 연구 (A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter)

  • 천중국;박출재;최금찬
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

구심성, 원심성, 등척성 운동방법에 따른 혈압과 심박수의 변화 (Blood Pressure and Heart Rate Responses to Concentric, Eccentric, Isometric Exercises)

  • 정연태;김기훈;구애련;한소영
    • 한국전문물리치료학회지
    • /
    • 제1권1호
    • /
    • pp.75-82
    • /
    • 1994
  • The purpose of this study is to determine cardiovascular reponses to concentric, eccentric and isometric exercise applied to the knee extensor muscle group. Exercise types studied were concentric, eccentric and isometric. The subjects were sixty healthy male volunteers who had no hypertension or cardiac disease. Heart rate, systolic and diastolic blood pressure were recorded prior to starting exercise. The subjects also performed 10RM on right lower extremity. A N-K table was used for three exercises to right knee extensors. Each exercise was selected randomly and applied to each subject 10 times in a 10 second. After each exercise, heart rate, systolic and diastolic blood pressure were recorded immediately. Findings were as follows concectric contractions had a greater effect on the increase of systolic blood pressure and heart rate than eccentric or isometric contractions. Diastolic blood pressure is influenced only by isometric contractions. Eccentric contractions have less effect on the increase of systolic blood pressure and heart rate than concentric or isometric contractions. We hope that the results of this experiment can be adapted to exercise programs for patients with cardiac disease.

  • PDF

A Study on the Measurement of Respiratory Rate Using a Respirator Equipped with an Air Pressure Sensor

  • Shin, Woochang
    • International journal of advanced smart convergence
    • /
    • 제11권4호
    • /
    • pp.240-246
    • /
    • 2022
  • In order to measure the respiratory rate, one of the major vital signs, many devices have been developed and related studies have been conducted. In particular, as the number of wearers of respirators increases in the COVID-19 pandemic situation, studies have been conducted to measure the respiratory rate of the wearer by attaching an electronic sensor to the respirator, but most of them are cases in which an air flow sensor or a microphone sensor is used. In this study, we design and develop a system that measures the respiratory rate of the wearer using an air pressure sensor in a respirator. Air pressure sensors are inexpensive and consume less power than the other sensors. In addition, since the amount of data required for calculation is small and the algorithm is simple, it is suitable for small-scale and low-power processing devices such as Arduino. We developed an algorithm to measure the respiratory rate of a respirator wearer by analysing air pressure change patterns. In addition, variables that can affect air pressure changes were selected, and experimental scenarios were designed according to the variables. According to the designed scenario, we collected air pressure data while the respirator wearer was breathing. The performance of the developed system was evaluated using the collected data.

Labyrinth Seal 의 누설 특성 실험 (An Experimental Study on the Leakage Characteristics of a Labyrinth Seal)

  • 하현천;변형현;박철현
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.141-146
    • /
    • 1999
  • An experimental investigation on the leakage characteristics of a labyrinth seal, high-low seal, is studied. Pressure distribution and leakage flow rate are measured along with the shaft speed and the pressure difference between the entrance and the exit. Pressure distribution vanes almost linearly along the seal and the leakage flow rate increases as the increase of the pressure difference. Furthermore, it is found that both the shaft speed and the shaft vibration have no influence on the leakage of the labyrinth seal.

  • PDF