• Title/Summary/Keyword: Pressure pulse parameter

Search Result 51, Processing Time 0.029 seconds

Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses (통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF

Analysis of Arterial Stiffness by Age Using Pulse Waveform Measurement of 5-levels Graded Pressure (5단계 가압 맥파측정에 의한 연령별 혈관 경화도 분석)

  • Kwon, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.107-120
    • /
    • 2010
  • Objectives : The aim of this study is to measure pulse waveforms by applying 5-level graded pressure, and selecting optimum pulse waveforms. Also to proposing the possibility of using AW(Area of the 1/3 upper height of h1) rate in respect to AT(Total Area) for risk assessment of hypertension or arteriosclerosis is another aim of the study. Methods : Pulse waveforms of normotensive were measured by 5-level graded pressure. The pulse waveforms well reflecting properties of blood vessel(having the largest h1) were selected for optimum pulse waveforms. Various parameters(h-parameter, t-parameter, and others) of optimum pulse waveforms were analyzed. AIx(Augmentation index) was calculated by height-parameters to assess arterial stiffness. The area rate of the 1/3 upper height for h1 in respect to total area was analyzed according to aging. Results : According to aging 1. in height-parameter, h2 and h3 were increased but h5 was decreased. 2. In time-parameter, t2, t3, and t5 were getting short. 3. Area of systolic period was increased, and that of diastolic period decreased. 4. AIx rose by aging. 5. AW was significantly increased despite no changes in AT. Conclusions : By analyzing optimum pulse waveforms of 5-level graded pressure method, we could complement weakness of single graded pressure method. Also, possibility of applying the AW rate to risk assessment of hypertension or arteriosclerosis was confirmed in normotensive population which might not be assessed by AIx.

Analysing of pulse wave parameter and typical pulse pattern for diagnosis in floating and sinking pulses (${\cdot}$ 침맥 진단에 유용한 맥상 파라메터 및 대표맥상 분석)

  • Lee, Yu-Jung;Lee, Jeon;Choi, Eun-Ji;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.93-101
    • /
    • 2006
  • Pulse feeling is one of the most important diagnosis method in Oriental medicine. But it is not easy to make an objective and standardized diagnosis. In this study, we found how to quantify diagnosis. Specially dally the high practicality in clinic, we search some parameters especially well-related to floating and sinking pulse by statistic analysis. By extension, we find the pulse patterns of the floating and sinking pulse. We choose 15 subjects diagnosed as floating pulse and 15 subjects diagnosed as sinking pulse by oriental doctors. And their pulse signals were acquired by Pulse analyzer which has piezoresistive pressure sensor. For the quantification of the floating and sinking pulse, at first, we examined the parameters which were highly correlated with oriental doctor's diagnosis. And then we derived pulse patterns of the floating-sinking pulse from preprocessed signal and its ensemble average. We also looked trend variation (PH-Curve) between contact and pulse pressure. As a result, statistically there is the biggest difference between contact pressure, the maximum pulse pressure, diastolic area (Ad) and floating and sinking data. Through the PH-Curve, which represented the relationship between contact and pulse pressure, we could divide the floating and sinking pulse clearly. As a basic research of pulse diagnosis algorithm, we can contribute to select essential parameters in diagnosis algorithm And using these diagnosis method, we expect to find typical pulse patterns and some useful parameters about other pulses like slow/rapid, large/fine pulse and so on. We hope that this study will contribute pulse objectification.

  • PDF

An Effect of Qi Gong Gymnastics Program on the Physiopsychological Parameter in Essential Hypertension (기공체조프로그램이 고혈압 환자의 생리.심리적 지수에 미치는 영향)

  • 이명숙;최의순
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.4
    • /
    • pp.856-868
    • /
    • 1998
  • The purpose of this study is to evaluate the effects of Qigong gymnastics exercise program on the physiopsychological parameter in essential hypertension. The design of the research was a one group pretest-posttest design. A total of 20 pateints with hypertension who were from forty to sixty-five years old participated in the study. The Qigong gymnastics program was carried out twice a week for thirty minutes or forty minutes for six weeks from 22, Sep. to 31, Oct. in 1997. In order to evaluate the effect of the Qigong gymnastics program physiological parameter (blood pressure, pulse rate, FVC, FEV1, Epinephrine, Norepinephrine, Cortisol) and psychological parameter(self-efficacy, Life satisfaction) were measured before and after the exercise program. Collected data was analyzed by the paired t-test with SAS package. The result are as follows : 1) There were significant decrease in systolic blood pressure and diastolic blood pressure, but there was no significant change in pulse rate. 2) There were no significant difference in FVC and FEV1 3) There were significant decrease in epinephrine, norepinephrine and cortisol. 4) There were significant improved in general self-efficacy and life satisfaction. 5) The effect of Qigong gymnastics program by measurement time on blood pressure and pulse rate were as follows : In a systolic blood pressure was gradually significant decreased from 1 week to 6 weeks and diastolic blood pressure was significantly decreased after 4weeks. But there was no significant change in pulse rate. This results suggest that Qigong gymnastics are an appropriate nursing intervention for clients with hypertension. For further research is necessary to reevaluate the effect with a letter experimental design and longer period than 8 weeks for the Qigong gymnastics program.

  • PDF

A Study on Arterial Characterization by using Up-stroke Time of Photoplethysmogram (용적맥파 상승시간에 의한 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.108-116
    • /
    • 2007
  • This paper proposed an analyzable parameter and its analytic method to provide more accurate information than currently employed 4 channels system which uses pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels for the characterization of arterial vessel. In order to verify the volume pulse waves on 4 sites were simultaneously acquired subjects aged from 12 to 81 years old. and the proposed parameters were extracted from time (UT) was then compared with blood pressure. Then, the regression analyses were done relationships among the proposed parameter and others, such as aging, pulse transit time pressure (BP). The followings are the results of linear regression analysis of the proposed parameter for total 50 normal subjects. We selected any two subjects (58 years and 27 years) and measured PPG (photoplethysmogram) and BP of before and after exercise. The coefficient of correlations between BP and UT observed was -0.928 for 50 years subject, and -0.922 for 20 years subject. For total 50 normal subjects, in case of correlation between the pulse transit time and BP, the result showed -0.170 on left side and -0.233 on right side, and the coefficient value of correlation between the pulse transit time and UT was -0.607 on left side and -0.510 on right side. UI is strongly correlated with the pulse transit time than BP. Hence, we believe that the proposed parameter is related with the index of arterial stiffness.

  • PDF

Study on the Difference of Pulse Waveform Parameter with Applied Variations of Pressure (측정가압에 의한 좌관부위(左關部位) 맥파요인 변화에 대한 실험 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Kyeong-Ho;Kang, Hee-Jung;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.59-72
    • /
    • 2010
  • Objectives : In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research, and to find the change of pulse waveform parameter with applied variation pf pressure. Methods : As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(left KWAN). In this research, we analyzed the change of the waveform according to five stage pressure. Results : The results were as follows; When we analyzed the change of the waveform according to pressure in the left KWAN, E, hl, h2 and A were the difference between 8ths pressure grades in 95% trust section. And t2, t4 were the difference between 8ths pressure grades in 95% trust section. W was the difference between 8ths pressure grades in 95% trust section. And h2/h1 was the difference between 6ths pressure grades in 95% trust section. There is the difference between 1st and 2nd grade & between 2nd and 5th grade in the case of t4/t2 in 95% trust section. And there is the difference between 1st and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of W/A in 95% trust section. And there is the difference between 1st and 2nd grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of A/E in 95% trust section. Conclusions : We found the statistically resonable differences between each pulse depending on the applied pressure. And Analysing the radial pulse(left KWAN) at 5 applied pressure levels may be useful to study on the pulse waveform diagnosis.

Laser micro-drilling of CNT reinforced polymer nanocomposite: A parametric study using RSM and APSO

  • Lipsamayee Mishra;Trupti Ranjan Mahapatra;Debadutta Mishra;Akshaya Kumar Rout
    • Advances in materials Research
    • /
    • v.13 no.1
    • /
    • pp.1-18
    • /
    • 2024
  • The present experimental investigation focuses on finding optimal parametric data-set of laser micro-drilling operation with minimum taper and Heat-affected zone during laser micro-drilling of Carbon Nanotube/Epoxy-based composite materials. Experiments have been conducted as per Box-Behnken design (BBD) techniques considering cutting speed, lamp current, pulse frequency and air pressure as input process parameters. Then, the relationship between control parameters and output responses is developed using second-order nonlinear regression models. The analysis of variance test has also been performed to check the adequacy of the developed mathematical model. Using the Response Surface Methodology (RSM) and an Accelerated particle swarm optimization (APSO) technique, optimum process parameters are evaluated and compared. Moreover, confirmation tests are conducted with the optimal parameter settings obtained from RSM and APSO and improvement in performance parameter is noticed in each case. The optimal process parameter setting obtained from predictive RSM based APSO techniques are speed=150 (m/s), current=22 (amp), pulse frequency (3 kHz), Air pressure (1 kg/cm2) for Taper and speed=150 (m/s), current=22 (amp), pulse frequency (3 kHz), air pressure (3 kg/cm2) for HAZ. From the confirmatory experimental result, it is observed that the APSO metaheuristic algorithm performs efficiently for optimizing the responses during laser micro-drilling process of nanocomposites both in individual and multi-objective optimization.

Method for Determining the Deficient and Solid Pulse with a New Pulse Wave Parameter (새로운 맥상 파라메터를 이용한 허실맥 판단 방법)

  • Kim, Sung-Hun;Kim, Jae-Uk;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • The pulse diagnosis is an important method in Oriental Medicine. Recently, there have been continuous attempts to replace the finger palpation by Oriental medical doctors (OMDs) by more objective tools based on machines, e.g., pulse analyzers. To improve the performance of the pulse analyzers, both the machine-appropriate interpretations for the pulse images appeared in the literature and the improvement in the repeatability and reproducibility of the measurement sensors are to be developed. As an attempt towards the transformation of the pulse images in terms of machine-appropriate language, in this work, we suggest an upgraded algorithm for the solid/deficient pulses, which are the two representative pulse images informing us how strong the pulse pressure is. It has been argued that one could determine the solid/deficient pulses by the maximum pulse pressure from pulse analyzers. However, by a clinical test, we found that the maximum pulse pressure alone is not sufficient to determine the solid/deficient pulses. In addition to the maximum pulse pressure, the mean pulse pressure averaged over for five different hold-down pressures(3-D MAC) is needed to improve the agreement with the OMD's decision for the solid/deficient pulse. We found that, among the data diagnosed with having either the solid pulse or deficient pulse by OMDs, the novel algorithm showed 86.0% diagnosis rate and 81.6% concordance rate.

Spray Characteristics of a Pulsed Liquid Jet into a Cross-flow of Air (아음속 횡단 유동장으로 펄스 분사된 액체 제트의 분무특성)

  • Lee, In-Chul;Byun, Young-Wu;Koo, Ja-Ye
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.61-64
    • /
    • 2008
  • The present study of these experiments are close examination of spray characteristics that are continuous liquid jet and modulated pressure pulse liquid jet. The experiments were conducted using water, over a range of cross-flow velocities from 42${\sim}$136 m/s, with injection frequencies of 35.7${\sim}$166.2 Hz. Between continuous cross-flow jet and pressure pulsed cross-flow jet for characteristics of penetration, breakup point, spray angle and macro spray shape are investigated experimentally. In cross-flow field, main parameter of liquid jet for breakup was cross-flow stream rather than pressure pulse frequency. As oscillation of the periodic pressure that could make liquid jet moved up and down, the mixing efficiency was increased. Also, a bulk of liquid jet puff was detected at upper field of liquid surface. So, this phenomenon has a good advantage of mixing spray from concentration of center area to outer area. Because of pressure pulsation frequency, an inclination of SMD for the structured layer was evanescent. Cross-sectional characteristics of SMD at downstream area were non-structured distributions. Then cross-sectional characteristics of SMD size were about same tendency over a range that is effect of spray mixing. The tendency of volume flux value for various frequency of pressure pulse was same distribution. And volume flux was decreased when the frequency of pressure pulse increase.

  • PDF

Welding Parameters Optimization of Pleated Type Metallic Filter Using response surface methodology (반응표면 분석법을 이용한 Pleated Type Filter의 용접조건 최적화에 관한 연구)

  • 박형진;강문진;최병구;이세헌
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.39-41
    • /
    • 2004
  • This study is to optimize the condition of pulse parameters using the response surface method in micro pulse TIG welding of pleated type metallic filter. The input parameters used were pulse current, base current, pulse duty, frequency and welding speed and the hydraulic pressure was used as the output parameter. The central composite design was designed using second order regression model, As the results, the optimal welding condition to manufacture the pleated type metallic filter was obtained.

  • PDF