• Title/Summary/Keyword: Pressure field

Search Result 3,788, Processing Time 0.035 seconds

An Analytical Solution of Dynamic Responses for Seabed under Flow and Standing Wave Coexisting Fields (흐름과 완전중복파와의 공존장하에서 해저지반내 동적응답의 해석해)

  • Lee, Kwang-Ho;Kim, Dong-Wook;Kim, Do-Sam;Kim, Tae-Hyung;Kim, Kyu-Han;Jeon, Jong-Hyeok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.2
    • /
    • pp.118-134
    • /
    • 2015
  • An analytical solution of dynamic responses for seabed in shallow, finite and infinite thicknesses has been developed under flow and standing wave coexisting field at a constant water depth condition. To do this, based on the Biot's consolidation theory, the seabed is assumed as a porous elastic media with the assumptions that pore fluid is compressible and Darcy law governs the flow. The developed analytical solution is compared with the previous results and is verified. Using the analytical solution the deformation, pore pressure, effective and shear stresses of seabed are examined under various given values of flow velocity, incident wave period and seabed thickness. From this study, it is confirmed that the seabed response is quite different depending on consideration of flow, which causes changing period and length of incident and reflection waves.

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

A Study on the Use of Science Citation Index (SCI) and Awareness of SCI Source Journals by Faculty Members at Korean Medical Colleges (국내 의과대학 교수들의 Science Citation Index (SCI) 이용 실태 및 SCI 학술지에 대한 인지도(認知度) 조사 연구)

  • Lee Choon-Shil
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.31 no.1
    • /
    • pp.29-52
    • /
    • 1997
  • A questionnaire survey was conducted to investigate the use of SCI and awareness of SCI source journals by fatuity members at Korean medical colleges. 104 out of 180 faculty members randomly chosen from four prestigious medical colleges returned the questionnaires malled to them. Korean medical researchers rarely used SCI as their main source of research Information. They rather used the MEDLINE to seek the research information probably because they are easily available from their local libraries. Furthermore. many respondents mistakenly Identified 'SCI journals ranked by Impact factor' lists found In Journal Citation Reports (JCR) with the SCI Itself. That Is. In Korean medical research community. the virtue of SCI Is not as an Index but as a source of SCI Journal Impact factor Information. It Is because the Interest in impact factor Is highly associated with the pressure to publish In one of those SCI source Journals. The collected data shows that even the medical professors at these prestigious medical colleges suffer from the lack of knowledge and information about SCI. SCI source journals and their Impact factors. Nontheless, core journal titles of a medical specialty selected by Korean medical professors are mostly high-Impact Journals of Its field (1.e.. belong to the upper 1/3) zone ranked by Impact factor). Within each specialty. the Journal ranks assigned to the selected core Journals by the respondents agree with the ranks by SCI Impact factor to a great extent. That Is. the Korean medical scientists awareness on SCI Journals as defined in this study is in good standing. Therefore. a policy of a medical college to require medical professors to publish In SCI Journals to be promoted or a policy to evaluate a researcher's work by the fact that his research papers are published In SCI Journals can be positively pursued.

  • PDF

Development of the Model for Activity Based Costing in the Hospital (의료기관의 활동기준원가 산출 모형)

  • Chun, Ki-Hong;Cho, Woo-Hyun;Kim, Bo-Kyung;Kim, Byung-Cho
    • Korea Journal of Hospital Management
    • /
    • v.6 no.2
    • /
    • pp.37-69
    • /
    • 2001
  • A new cost management system, called Activity Based Costing (ABC) system, has arisen to solve the limitation of a Traditional Cost Accounting (TCA) system until last two decades and ABC has been applied by many companies. TCA systems have limitation in tracing cost because they arbitrarily allocate overhead cost to the cost objects without standard for direct cost distribution. ABC is an accounting system that assigns costs to products or services based on the resources they consume. The costs of all activities are traced to the products for which they are performed. Therefore ABC is a cost management system that provides a matrix to accurately quantify consumed resources triggered by activities and activities triggered by products and services. There is little implementation of ABC in the health services field, one of service industries, due to complicated and many activities, and volatile cost object. However, the necessity for applying reasonable cost accounting system is largely issuing as strategy responding hostile environment, and financial pressure, and it is imperative to implement the Activity Based Costing (ABC) system. Therefore, this study presents the framework to develop ABC system for total health service organizations. Cost objects in this study base on medical service activities per health insurance claim from one general hospital located in Metropolitan Statistical Areas (MSAs). Medical service activities include all health insurance claims in the hospital. The purpose of the study is presenting useful tools and basic frame to develop Activity Based Costing system for health service organizations which want to use ABC system. The steps to develop ABC system for health service organizations are following: 1. Identifying of activity centers; 2. Definition of cost objects and activity by activity center; 3. Analysis of activity and tracing activity contribution; 4. Allocation of direct cost for specific activity; 5. Allocation of indirect cost for specific activity; 6. Allocation of depreciation for facilities, applicants, and consumption goods; 7. Allocation of administration cost; 8. Allocation of cost among activity centers; and 9. Tracing cost of cost objects by activity center. This study identified necessary information from existing reports which hospitals generally made by each step, and defined outcome which had to be produced in each step using this information. The steps of this study had limitation to apply all different size hospitals because the steps were structured ABC system by one hospital, however, this study used similar basic framework and methods with general cases. When a health service organization want to apply Activity Based Costing (ABC) system on all activities of it in future days, this study is very useful to design system structure in the health service organization.

  • PDF

Development of hypothermic preservation solution for the human dermal fibroblast using protein hydrolysates (단백질 가수분해 물을 이용한 인간 피부 섬유아세포의 저온 보존액 개발)

  • Byoun, Soon-Hwi;Choe, Tae-Boo
    • KSBB Journal
    • /
    • v.24 no.3
    • /
    • pp.312-320
    • /
    • 2009
  • Stable cell preservation is an essential factor in the regenerative medicine for cell therapies and transplantation of biologic materials. In this study, we studied to provide more stable hypothermic preservation by protection of cell damage during the preservation at $4^{\circ}C$. The result of searching for key components that have excellent efficacy in hypothermic preservation of cells, we have identified the fact that the hypothermic preservation adding protein hydrolysates such as yeast hydrolysate is far superior to others. All protein hydrolysates that are derived from animal, plant and microbe sources have superior efficacy, especially the peptides which have molecular weights under 10 kDa have the best efficacy among the components of protein hydrolysate. The protein hydrolysates prevented the decrease of ATP level in the cells caused by hypothermic environment and they inhibited the generation of ROS. Adding antioxidants and control agents of osmotic pressure were showed to have more superior efficacy in hypothermic preservation. Finally, KUL261 solution (DMEM/F12 1 : 1 medium, yeastolate 1%, $\alpha$-tocopherol $100{\mu}M$, dextran 2.5%), the preservation solution developed in this study, showed the best efficacy in both cell viability and cell growth more than other conventional preservation solutions. In conclusion, the improved hypothermic preservation solution that contains the protein hydrolysates as a key component provide the best preservation efficacy. It provides better efficacy than other preservation solutions and will contribute to both the development of regenerative medicine and global commercialization in this therapeutic field.

Field Measurements and Review of the Curve Squeal Noise of Urban Railways (도시철도 차량 주행시 곡선스킬소음 실험 및 고찰)

  • Kim, Jae-chul;Kim, Kwanju;Lee, Junheon;Kim, Jiyong
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.165-172
    • /
    • 2017
  • High frequency squeal noise can be generated when a railroad vehicle runs a sharp curved section; this noise causes environmental complaints and excessive wear on the wheel and the railroad track. In this paper, curved squeal noise experiments on a commercial railway were carried out to investigate this phenomenon. The relationship of the squeal noise pressure level, the frequency characteristics, the railway running speed, and the modal behavior of the wheel were investigated. At the same time, the lateral motion of the wheel relative to the rail was captured using a video camera; wheel movement was calculated when the noise was generated. queal noise occurred at the highest level at the inner front wheel; this phenomena is considered to be related to the lateral vibration response characteristics of the wheel. It can be seen that the magnitude of this squeal noise is not directly related to the increase in vehicle speed.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

The Spin Reorientations in $\alpha-Fe_2O_3$ Thin Film ($\alpha-Fe_2O_3$ 박막에서 스핀 재 정렬에 관한 연구)

  • 서정철;이호선
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • $\alpha$-Fe$_2$O$_3$ thin films were prepared on Si substrate by a pulsed laser deposition system and characterized by X-ray and Mossbauer spectroscopy. The appropriate conditions of pulsation was the power of 5.128 W/cm2 at on oxygen pressure of 0.1 Torr at a substrate temperature of 30$0^{\circ}C$. After that the film was heated at 80$0^{\circ}C$ for 1 day. The particles shape deposited on the film was ellipsoidal and the average length and width were 200~300 nm, 70~150 am respectively. The crystal structure was conformed to be of corundums symmetry with the hexagonal unit cell having a lattice constant of u = 5.03$\pm$0.05 $\AA$, c = 13.735$\pm$0.05 $\AA$. The average angles between the atomic spin and the magnetic hyperfine field of Fe ion were 38$^{\circ}$and 48$^{\circ}$ at above and blow the Morin transition temperature respectively. The Morin transition was found to occur at the temperature ranges from 200 K to room temperature and atomic spin direction was assumed to change from 48$^{\circ}$ to 80$^{\circ}$in respect to the c-axis.

  • PDF

Application of LID Methods for Sustainable Management of Small Urban Stream Using SWMM (SWMM 모델을 이용한 지속 가능한 도시 소하천 관리를 위한 LID 기법의 적용 방안 연구)

  • Han, Yanghui;Seo, Dongil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.691-697
    • /
    • 2014
  • Though the upper stream basin area of Gwanpyung-Cheon in Daejeon, Korea is protected as Green Belt Zone, the stream is under constant environmental pressure due to current agricultural practices and infrastructure development in its basin area. To develop appropriate integrated water resources management plan for the stream, it is necessary to consider not only water quality problems but also water quantity aspect. In this study, Storm Water Management Model (SWMM) was calibrated and validated with sets of field measurements to predict for future water flow and water quality conditions for any rainfall event. While flow modeling results showed good agreement by showing correlation coefficient is greater than 0.9, water quality modeling results showed relatively less accurate levels of agreements with correlation coefficient between 0.67 and 0.87. Hypothetical basin development scenarios were developed to compare effect on stream water quality and quantity when Low Impact Development (LID) technologies are applied in the basin. The results of this study can be used effectively in decision making processes of urban development Gwanpyung-Cheon area by comparing basin management alternatives such as LID methods.

The Effects of Job Stress of Construction Workers on Construction Accidents and Turnover Intention (건설업 종사자의 직무스트레스가 건설재해 발생과 이직의도에 미치는 영향)

  • Park, Yong-Su;Park, Soo-Yong;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.3
    • /
    • pp.59-65
    • /
    • 2017
  • The purpose of this study is to investigate the factors and effects of job stress of construction workers on construction accidents and turnover intention in order to improve the field work environment of construction industry which shows higher industrial accidents than other industries. To this end, research models and hypotheses were established based on previous research, and the questionnaire was distributed to 10 construction companies in Daejeon, Sejong, and Chungcheong provinces. The 301 data collected were performed statistical analysis such as basic statistical analysis, factor analysis, reliability analysis, correlation analysis, regression analysis, and logistic regression analysis using the statistical package (IBM SPSS 22). The results of this study are summarized as follows. First, job stress has a significant effect on accident occurrence. Among the sub-factors of job stress, there was positive (+) influence on work culture and relationship conflict between peers, and organizational system had negative influence. Job demands, compensation incompetence, and job instability were not statistically significant. Therefore, it is necessary to concentrate on the factors of work culture, organizational system, and relationship conflict in the construction site. Second, job stress has positive effect on turnover intention. Job stress, inadequacy of compensation, and work culture were positively related to turnover intention. Third, job demands have a slightly greater impact than compensatory inadequacies. The factors that make the job turnover more important are the excessive job burdens such as respect, internal motivation, responsibility rather than expectation non-conformity, time pressure, increase of work load. Therefore, in order to reduce the turnover intention of the construction worker, it is necessary to pay attention to improvement of the job requirement. Fourth, the worker's job stress could overcome by exercise and fatigue elimination, work environment management, and self-opening for others. It is necessary to establish a work environment management system for counseling and intimacy formation to open up the exercise and fatigue relief program of the workers at the construction site and to open themselves between the workers and the supervisors.