• 제목/요약/키워드: Pressure cooling

검색결과 1,371건 처리시간 0.028초

항공기용 가스터빈의 고압 냉각터빈 노즐에 대한 복합열전달 해석 (Conjugate Heat Transfer Analysis for High Pressure Cooled Turbine Vane in Aircraft Gas Turbine)

  • 김진욱;박정규;강영석;조진수
    • 한국유체기계학회 논문집
    • /
    • 제18권2호
    • /
    • pp.60-66
    • /
    • 2015
  • Conjugate heat transfer analysis was performed to investigate the flow and cooling performance of the high pressure turbine nozzle of gas turbine engine. The CHT code was verified by comparison between CFD results and experimental results of C3X vane. The combination of k-${\omega}$ based SST turbulence model and transition model was used to solve the flow and thermal field of the fluid zone and the material property of CMSX-4 was applied to the solid zone. The turbine nozzle has two internal cooling channels and each channel has a complex cooling configurations, such as the film cooling, jet impingement, pedestal and rib turbulator. The parabolic temperature profile was given to the inlet condition of the nozzle to simulate the combustor exit condition. The flow characteristics were analyzed by comparing with uncooled nozzle vane. The Mach number around the vane increased due to the increase of coolant mass flow flowed in the main flow passage. The maximum cooling effectiveness (91 %) at the vane surface is located in the middle of pressure side which is effected by the film cooling and the rib turbulrator. The region of the minimum cooling effectiveness (44.8 %) was positioned at the leading edge. And the results show that the TBC layer increases the average cooling effectiveness up to 18 %.

압력감응페인트를 이용한 확대/축소 유로에서의 막냉각 효율 측정 (Measurement of the Film Cooling Effectiveness using Pressure Sensitive Paint on Convergent/Divergent Channel)

  • 박승덕;이기선;김성하;김학봉;곽재수;김춘택;양계병
    • 한국유체기계학회 논문집
    • /
    • 제11권6호
    • /
    • pp.31-37
    • /
    • 2008
  • Film cooling effectiveness on the convergent or divergent channel was measured by pressure sensitive paint technique. The channel convergent or divergent angle was changed from $-5^{\circ}$ to $10^{\circ}$ and the tested blowing ratios were 0.5, 1 and 2. Results showed that the film cooling effectiveness on the convergent channel was not much affected by the convergent angle. With divergent film cooled surface, the film cooling effectiveness near the injection hole decreased as the divergent angle increases. However, the film cooling effectiveness at far downstream from the hole showed opposite trend. For the non-film cooled surface inclined case, the film cooling effectiveness was not much affected by the divergent angle.

공기측 파울링에 의한 에어컨 열교환기의 성능분석 연구 (Performance Evaluation of Heat Exchangers due to Air-side Particulate Fouling in the Air Conditioners)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.447-453
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the cooling performance and pressure drop on the air-side particulate fouling of heat exchangers for air conditioners. Air conditioners being used in the field such as inn, restaurant, and office are collected in chronological used order. Test results show 15% decrease of the cooling capacity and 44% increase of the pressure drop for the 7 years air conditioners used in the seaside inn.

터보팬 엔진에서 터빈 냉각이 성능에 미치는 영향에 대한 수치적 해석 (Parametric Cycle Analysis of a Turbofan Engine with Turbine Cooling)

  • 황진석;문희장;구자예
    • 한국항공운항학회지
    • /
    • 제14권1호
    • /
    • pp.15-21
    • /
    • 2006
  • Parametric cycle analysis of a dual-spool, mixed exhaust turbofan engine with turbine blade cooling were described to investigate the effect of turbine blade cooling on the engine performance such as specific thrust and thrust specific fuel consumption. Coolant of low pressure turbine triggers high engine performance loss and cooling effect loss in high pressure turbine. Therefore low pressure turbine coolant should be much more considered for effective design.

  • PDF

The Effect of Solution Pressure to the Release in a Supercooled Aqueous Solution

  • Kang, Chae-Dong;Kim, Byung-Seon;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.25-31
    • /
    • 2009
  • Supercooled type ice storage system with aqueous solution (or water) may have trouble with non-uniform release of supercooling even though it contributes to the simplicity of system and ecological improvement. The non-uniform release increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to suppress the release of the supercooling, a cooling experiment was tried to an ethylene glycol(EG) 3 mass% solution corresponding with pressurization. Also, the frequency ratio of the release of the supercooling was measured to the pressurization from 101 to 505 kPa. At results, the frequency ratio of supercooling release tends to decrease as the pressure of the aqueous solution increased in each cooling rate. Moreover, it tends to decrease as the cooling rate of the solution decreased in each pressure.

Experimental Study on the Film Cooling Effectiveness on a Flat Plate with Anti-Vortex Holes

  • Park, Soon Sang;Park, Jung Shin;Kwak, Jae Su
    • International Journal of Aerospace System Engineering
    • /
    • 제1권1호
    • /
    • pp.1-9
    • /
    • 2014
  • In this paper, the effects of the anti-vortex hole angle and blowing ratio on the flat plate film cooling effectiveness were experimentally investigated. For the film cooling effectiveness measurement, pressure sensitive paint technique was applied. The experiments were conducted for cylindrical and anti-vortex film cooling holes, and three blowing ratios of 0.25, 0.5, and 1.0 were tested. Two anti-vortex hole angles of 0 and 15 degree with respect to the flow direction were considered. For the cylindrical hole case, the film cooling effectiveness decreased as the blowing ratio increased because of the coolant lift-off. For the angle anti-vortex hole cases, however, higher blowing ratio resulted in higher film cooling effectiveness due to the reduced actual blowing ratio and diminished kidney vortex. For all blowing ratio, the angled anti-vortex hole case showed the highest film cooling effectiveness.

암모니아 액화 시나리오에 따른 그린암모니아 합성 공정의 경제성 및 환경 영향도 평가 (Techno-economic Analysis and Environmental Impact Assessment of a Green Ammonia Synthesis Process Under Various Ammonia Liquefaction Scenarios)

  • 김건영;송인서;구보람;박기호
    • Korean Chemical Engineering Research
    • /
    • 제62권2호
    • /
    • pp.163-172
    • /
    • 2024
  • 본 연구에서는 이산화탄소를 배출하지 않고 수소를 운반할 수 있는 그린 암모니아 공정의 효율적인 설계를 위해 암모니아 액화 시나리오를 다르게 설계하고 이에 대한 경제성 및 환경 영향도 평가를 수행하였다. 순도 99.9 mol%의 148 kmol/hr 액화 암모니아를 생산물로 얻는 것을 목표로 설정하였고 후처리 단계에서 냉각단계 전 기-액분리를 통해 일정량의 액화 암모니아를 분리하고 고압에서 냉각하는 고압 냉각 공정과 기-액분리 과정 없이 바로 감압 후 냉각하여 기-액분리를 시켜 최종생산물을 얻는 저압 냉각 공정의 두 가지 케이스를 설정했다. 이에 대한 타당성 평가를 위해 Aspen Plus를 활용한 시뮬레이션을 수행하였다. 고압 냉각 공정은 많은 기-액분리 공정과 열교환기를 사용하여 초기장치 비용이 부담되지만 상대적으로 총 유틸리티 비용이 91.03 $/hr, duty가 2.81 Gcal/hr 낮아 유지비용이 적게 든다. 저압 냉각 공정은 초기 장치 비용이 낮고 운전이 용이하지만 급격한 압력 강하로 운전이 불안정한 것을 확인 하였다. 환경 영향도 평가 결과 고압 냉각 공정이 저압 냉각 공정보다 전력 사용량을 기준으로 산출한 이산화탄소 환산톤 배출 계수가 0.83 tCO2eq 더 낮아 환경친화적 임을 확인할 수 있었다. 본 연구 결과를 통해 향후 그린 암모니아 합성 공정에서 여러 상황에 적절한 설계안을 도출할 수 있는 데이터베이스를 확보할 수 있다.

에너지 절약용 냉방사이클 (Cooling Cycle for Energy Saving)

  • 이흥주;김용구
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

$CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석 (Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle)

  • 노건상;손창효
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF

자동차 프런트 엔드 쿨링팬 주위의 점성유동 해석 (Numerical Analysis of the Viscous Flow Around a Front End Cooling Fan of the Car)

  • 오건제;배춘근
    • 한국산업융합학회 논문집
    • /
    • 제10권4호
    • /
    • pp.221-226
    • /
    • 2007
  • Viscous flow around a front end cooling fan of the car is numerically investigated. The Navier-Stokes equations and the continuity equation are solved in the flow domain. The Reynolds stresses are modelled using the $k-{\varepsilon}$ turbulence model. The governing equations are discretized with the Finite Volume Method. The pressure and the velocity are linked with the SIMPLE algorithm. Flow and pressure characteristics around the fan are investigated. The pressure sharply increases through the fan blade. Pressure variations on the pressure and suction sides of the fan are well represened in the calculations. The flow streamlines in the blade passage are nearly parallel to the blade, but the slope of streamlines increases near the tip.

  • PDF