• Title/Summary/Keyword: Pressure control algorithm

Search Result 284, Processing Time 0.082 seconds

Development of an Active Tire Pressure Control System Using a Tire Simulator (타이어 시뮬레이터를 이용한 능동형 타이어 공기압 제어 시스템 개발)

  • Lee, Kyu-Cheol;Ryu, Kwan-Hee;Rhee, Joong-Yong;Hong, Ji-Hyang;Kim, Hyeok-Joo;Yu, Ji-Hoon
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.21-30
    • /
    • 2010
  • This study was performed to develop an active tire pressure control system that can adjust tire pressure to the optimum level according to traveling and working condition of agricultural tractor. For the development of active tire pressure control system, pneumatic supplier, solenoid valve block including pneumatic supply line, infinite rotation type pneumatic supplier with rotary joint unit, tire pressure transceiver module and control algorithm were developed. Also, tire simulator was developed. Using this tire simulator, the feasibility of each part constructing actual system was tested by checking the performance. The average communication success ratio was 98.3% between tire pressure transmitter and receiver module according to the various tire rotational speed and data receipt position of receiver module. The communication performance of the developed transmitter and receiver module was very stable in any condition. The tire pressure control system was accomplished by using the proportional control algorithm in this study. Also tire pressure control performance of developed control system was analyzed by using the tire simulator. As a result of control performance analysis to the developed system, the developed control system took 307 seconds to inflate agricultural tractor's tire from 50 kPa to 180 kPa. In opposite case, it took 210 seconds. Also it was able to control the tire pressure accurately under ${\pm}0.9%$ (FS) in any condition.

Position Sensorless Control of PMSM Drive for Electro-Hydraulic Brake Systems

  • Yoo, Seungjin;Son, Yeongrack;Ha, Jung-Ik;Park, Cheol-Gyu;You, Seung-Han
    • Journal of Drive and Control
    • /
    • v.16 no.3
    • /
    • pp.23-32
    • /
    • 2019
  • This study proposed a fault tolerant control algorithm for electro-hydraulic brake systems where permanent magnet synchronous motor (PMSM) drive is adopted to boost the braking pressure. To cope with motor position sensor faults in the PMSM drive, a braking pressure controller based on an open-loop speed control method for the PMSM was proposed. The magnitude of the current vector was determined from the target braking pressure, and motor rotational speed was derived from the pressure control error to build up the braking pressure. The position offset of the pump piston resulting from a leak in the hydraulic system is also compensated for using the open-loop speed control by moving the piston backward until it is blocked at the end of stroke position. The performance and stability of the proposed controller were experimentally verified. According to the results, the control algorithm can be utilized as an effective means of degraded control for electro-hydraulic brake systems in the case that a motor position sensor fault occurs.

Characteristics Analysis of Automatic Transmission for the Wheel-Loader with Shift Control Algorithm (변속제어 알고리즘을 적용한 휠로더 자동변속기 특성 해석)

  • Oh, Joo-Young;Yun, Ung-Kwon;Park, Young-Jun;Lee, Geun-Ho;Song, Chang-Seop
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.639-645
    • /
    • 2011
  • Wheel-loader is a construction vehicle for uploading soil or sand into truck and transportation of materials, which requires large driving power and high rotational speed. To improve the working efficiency, the operator has to shift gears and control levers for bucket & boom simultaneously. Therefore, the automatic transmission has been introduced to enhance operator's convenience and enable effective operation. To develop the automatic transmission for the wheel-loader, technologies such as gears and a clutch-pack design and shift algorithm are required for improvement of shift quality. In this paper, the shift algorithm for the wheel-loader was developed and its shift pattern was analyzed. As the shift control is affected by the pressure profile for the clutch control, the shift quality depending on the pressure profile has been evaluated using experiment and simulation model analysis.

Development of Optimum High Pressure Algorithm for a Transcritical $CO_2$ Mobile Air-Conditioning System ($CO_2$ 자동차 에어컨 시스템의 최적 고압 설정 알고리즘 개발에 관한 연구)

  • Lee, Jong-Bong;Lee, Jun-Kyoung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.159-165
    • /
    • 2008
  • This paper deals with the optimum high pressure control algorithm for a transcritical $CO_2$ mobile air-conditioning system with belt-driven compressor to achieve the maximum COP. The experiments were performed to find out the maximum COP conditions with various operating conditions. The experimental results showed that the COP was increased and then decreased with increase of the refrigerant high pressure for the system. Therefore the value of high pressure which has maximum COP could be selected. Furthermore, the strong (linear) relation between the optimum high pressure and the gas cooler outlet temperature was revealed, which suggests the use of a simple controller with only one parameter for the transcritical $CO_2$ cycle.

The Control System of a Robot Bed for Caring Pressure Ulcer

  • Kim, Jungae;Lee, Youngdae;Cho, Hyunkyung
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.254-259
    • /
    • 2020
  • The medical bed developed in this study is an electrically driven segmental keyboard. First describe the instrument of the segmental bed specially designed for pressure ulcer prevention, then the motor control system and pressure ulcer prevention operation of the bed. The main factor of pressure ulcer generation is displayed as body pressure x time, and when the keyboard falls, the body pressure becomes zero, and the pressure becomes higher than the threshold even if the body pressure is above the threshold, the pressure control algorithm has been developed. Therefore, using the proposed pressure control method, it has no particular ulcer occurred theoretically.

Fault-tolerant control system for once-through steam generator based on reinforcement learning algorithm

  • Li, Cheng;Yu, Ren;Yu, Wenmin;Wang, Tianshu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3283-3292
    • /
    • 2022
  • Based on the Deep Q-Network(DQN) algorithm of reinforcement learning, an active fault-tolerance method with incremental action is proposed for the control system with sensor faults of the once-through steam generator(OTSG). In this paper, we first establish the OTSG model as the interaction environment for the agent of reinforcement learning. The reinforcement learning agent chooses an action according to the system state obtained by the pressure sensor, the incremental action can gradually approach the optimal strategy for the current fault, and then the agent updates the network by different rewards obtained in the interaction process. In this way, we can transform the active fault tolerant control process of the OTSG to the reinforcement learning agent's decision-making process. The comparison experiments compared with the traditional reinforcement learning algorithm(RL) with fixed strategies show that the active fault-tolerant controller designed in this paper can accurately and rapidly control under sensor faults so that the pressure of the OTSG can be stabilized near the set-point value, and the OTSG can run normally and stably.

A Back-Pressure Algorithm for Lifetime Extension of the Wireless Sensor Networks with Multi-Level Energy Thresholds (센서네트워크 수명 연장을 위한 에너지 임계값 기반 다단계 Back-Pressure 알고리즘)

  • Jeong, Dae-In
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12B
    • /
    • pp.1083-1096
    • /
    • 2008
  • This paper proposes an energy-aware path management scheme, so-called the TBP(Threshold based Back-Pressure) algorithm, which is designed for lifetime extension of the energy-constrained wireless sensor networks. With the goal of fair energy consumptions, we extensively utilize the available paths between the source and the sink nodes. The traffic distribution feature of the TBP algorithm operates in two scales; the local and the whole routing area. The threshold and the back-pressure signal are introduced for implementing those operations. It is noticeable that the TBP algorithm maintains the scalability by defining both the threshold and the back-pressure signal to have their meanings locally confined to one hop only. Throughout several experiments, we observe that the TBP algorithm enhances the network-wide energy distribution. which implies the extension of the network lifetime. Additionally, both the delay and the throughput outcomes show remarkable improvements. This shows that the energy-aware path control scheme holds the effects of the congestion control.

Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve (고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF

A Mobile Robot Based on Slip Compensating Algorithm for Cleaning of Stud Holes at Reactor Vessel in NPP

  • Kim, Dong Il;Moon, Young Jun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.84-91
    • /
    • 2020
  • The APR1400 reactor stud holes can be stuck due to high temperatures, high pressure, prolonged engagement, and load changes according to pressure changes in the reactor. Threaded surfaces of a stud hole should be cleaned for the sealing of pressure in reactor vessel by removing any foreign materials which may exist in the stud holes. Human workers can access to the stud hole for the cleaning of stud holes manually, but the radiation exposure of human workers is increased. Robot is an effective way to work in hazardous area. So we introduced robot for the cleaning of stud holes. Localization of mobile robots is generally based on odometry, but with increased mileage, position errors can be accumulated. In order to eliminate cumulative error and to ensure stability of its driving, laser sensors and new control algorithm were utilized. The distance between the robot and the wall was measured by laser sensors, and the control algorithm was implemented so as to travel the desired trajectory by using the measured values from sensors. The performance of driving and hole sensing were verified through field application, and mobile robot was confirmed to be applicable to the APR 1400 NPP.

Intelligent Algorithms for the Effective Control of High-side Pressure and Indoor Air Temperature of a $CO_2$ Automotive Air Conditioner System (자동차 $CO_2$ 냉방시스템의 고압과 실내온도의 효과적인 제어를 위한 지능알고리즘)

  • Jang, Kyung-Chang;Han, Do-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.480-485
    • /
    • 2005
  • In the respect of the environmental protection viewpoint, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be newly developed, because properties of $CO_2$ are different compared with those of classical refrigerants. Especially, high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. In this study, intelligent control algorithms for a $CO_2$ system were developed ‘ These are a high-side pressure control algorithm and an indoor air temperature control algorithm. These algorithms were analysised by using dynamic models of a $CO_2$ system.

  • PDF