• Title/Summary/Keyword: Pressure biofeedback

Search Result 88, Processing Time 0.02 seconds

Pelvic Floor Muscle Exercise by Biofeedback and Electrical Stimulation to Reinforce the Pelvic Floor Muscle after Normal Delivery

  • Lee, In-Sook;Choi, Euy-Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.8
    • /
    • pp.1374-1380
    • /
    • 2006
  • Purpose. This study was conducted to investigate the effectiveness of pelvic floor muscle exercise using biofeedback and electrical stimulation after normal delivery. Methods. The subjects of this study were 49 (experimental group: 25, control group: 24) postpartum women who passed 6 weeks after normal delivery without complication of pregnancy, delivery and postpartum. The experimental group was applied to the pelvic muscle enforcement program by biofeedback and electrical stimulation for 30 minutes per session, twice a week for 6 weeks, after then self-exercise of pelvic floor muscle was done 50-60 repetition per session, 3 times a day for 6 weeks. Maximum pressure of pelvic floor muscle contraction (MPPFMC), average pressure of pelvic floor muscle contraction (APPFMC), duration time of pelvic floor muscle contraction (DTPFMC) and the subjective lower urinary symptoms were measured by digital perineometer and Bristol Female Urinary Symptom Questionnaire and compared between two groups prior to trial, at the end of treatment and 6 weeks after treatment. Results. The results of this study indicated that MPPFMC, APPFMC, DTPFMC were significantly increased and subjective lower urinary symptoms were significantly decreased after treatment in the experimental group than in the control group. Conclusions. This study suggested that the pelvic floor muscle exercise using biofeedback and electrical stimulation might be a safer and more effective program for reinforcing pelvic floor muscle after normal delivery.

Effects of respiratory reeducation exercise using a pressure biofeedback unit on the quality of life of persons with stroke

  • Kim, Hyun Seung
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.4
    • /
    • pp.238-243
    • /
    • 2020
  • Objective: The purpose of this study was to confirm the validity of a respiratory retraining exercise using pressure biofeedback units among individuals with stroke as an effective intervention for improving quality of life. Design: Randomized controlled trial. Methods: Thirty patients with stroke were recruited as subjects. Among them, 15 patients were randomly assigned to an experimental group performing lumbar stabilization exercise and respiratory retraining exercise, and the other 15 patients were randomly assigned to a control group conducting only lumbar stabilization exercises. Exercises were conducted 3 times a week for 6 weeks, and quality of life was evaluated in the pre-test, 3 weeks and 6 weeks periods. The respiratory retraining exercises were performed using a pressure biofeedback unit and the degree of the quality of life was measured using the Stroke- Specific Quality of Life. For data analysis on the study results, a two-way repeated ANOVA was used in order to observe for changes in the measured variables according to time for both groups. If there was a reciprocal action between the groups and the time in the effect test within the entities, a one-way repeated ANOVA was implemented and was statistically processed. Results: There was a significant difference in the main effect test between the 2 populations depending on the duration of the experiment (6 weeks) (p<0.05). Conclusions: The above results showed that respiratory retraining exercises may provide positive effects in the treatment of stroke as the quality of life showed significant differences according to the duration of treatment.

The Effects of Trunk Stability Education in Pelvic Stabilization (체간안정화 교육이 골반안정성에 미치는 효과)

  • Lee, Hando;Kim, Hyerim;Kim, Hyunjung;Choi, Eunhwa;Son, Byeonggi;Park, Jungbo;Park, Juyoul;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.1 no.4
    • /
    • pp.57-66
    • /
    • 2013
  • PURPOSE: The purpose of this study was to investigate the effects using pressure biofeedback and teaching abdominal hollowing exercise on pelvic stabilization during the active straight leg raising test. METHOD: The subjects were divided into 3 groups who were fourty eight healthy participants, aged 20~25 years recruited for this study. First group wad control group. This group didn't any education. Second group was teaching them for a week. And last group was teaching abdominal hollowing exercise. The rotation angles of pelvic were measured by the motion anayalyser on flat surface and on form roll for the active leg raising. RESULT: Using pressure biofeedback and teaching abdominal hollowing exercise groups were significantly effective than control group in rotation angles of pelvis. And using pressure biofeedback group was more effective than teaching core stability muscles contraction group. CONCLUSION: This study suggested that patients with low back pain and pelvic instability can improve pelvic stabilization through pressure biofeedback and teaching abdominal hollowing exercise.

The Effect of Breathing Biofeedback Training in the Stress of Nursing Students in Clinical Practice. (호흡바이오피드백 훈련이 간호대학생의 임상실습시 스트레스에 미치는 효과)

  • Kwon Young-Sook;Kim Tae-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.2
    • /
    • pp.169-184
    • /
    • 1999
  • The purpose of this study was to identify the effects of breathing biofeedback training on the stress of nursing students in clinical practice. The research design was a nonequivalent control group pretest-posttest design. The subjects of this study were 39 nursing students from the College of Nursing of K University. The study was conducted from July 20 to September 3, 1998. The subjects were assigned to one of two groups : the experimental group (19 students), and the control group (20 students). The breathing biofeedback training was performed 12 times with the experimental group. The level of psychological stress was measured using the State Anxiety Inventory, Profile of Mood State, and Visual Analogue Stress Scale. The level of physiological stress was measured using pulse rate and blood pressure. The data were analyzed using descriptive statistics, $x^2-test$, t-test, and repeated measures of ANOVA. The results of study are as follows : 1) State anxiety scores were not significantly different between the experimental group and the control group after the biofeedback training. 2) Profile of mood state scores were not significantly different between the experimental group and the control group after the biofeedback training. 3) Visual Analogue Stress Scale scores were significantly different between the experimental group and the control group after the biofeedback training(F=11.68, p=0.002). 4) Pulse rates were not significantly different between the experimental group and the control group after the biofeedback training. 5) Systolic blood pressures were significantly different between the experimental group and the control group after the biofeedback training(F=5.44, p=0.025). 6) Diastolic blood pressures were not significantly different between the experimental group and the control group after the biofeedback training. On the basis of the above findings, the following recommendations for further study are made ; 1) Identification of the effects of breathing biofeedback training at times of high stress during clinical practice. 2) Identification fo the effects of stress reduction according to the frequency of the breathing biofeedback training.

  • PDF

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

The Efficacy of Biofeedback and Electrical Stimulation by Kontinence HMT2000 in the Treatment of Stress Urinary Incontinence Patients (복압성요실금 환자에서 Kontinence HMT2000을 이용한 바이오피드백과 전기자극치료의 효과)

  • Bae, Yeun-Kyoung;Lee, Dae-Hyung;Park, Sung-Chul;Jin, Sung-Hee;Koh, Min-Whan;Lee, Tae-Hyung
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.1
    • /
    • pp.36-44
    • /
    • 2003
  • Background: To evaluate the efficacy of EMG biofeedback and pelvic floor electrical stimulation in the stress urinary incontinence patients by Kontinence HMT2000. Materials and Methods: A group of 14 patients with stress urinary incontinence were treated with combined biofeedback and intravaginal electrical stimulation during 12 sessions from 2 weeks to 6 weeks. Results: At immediate post treatment, subjective cure rate was 28% and improvement rate was 57% and failure rate was 15%. Thus the overall success rate for this treatment was 85%. The result of 3 months after treatment showed cure rate 14% and improvement rate was 43%. Intravaginal pressure increased by an average of 11.9 cmH2O. Increased vaginal pressure was found in 93% of the patients and more than 50% increment of intravaginal pressure was 71%. Conclusions: Combined biofeedback and pelvic floor electrical stimulation by use of Kontinence HMT2000 is effective for the patients who have good compliance, relative low degree stress urinary incontinence. In order to attain good results, a well structured program that teaches specific muscle exercise and the patients should be followed by regular interval reinforcement treatment.

  • PDF

Effects of Electric Stimulation and Biofeedback for Pelvic Floor Muscle Exercise in Women with Vaginal Rejuvenation Women (회음부 성형수술 여성에서 전기자극과 바이오피드백을 이용한 골반저근운동의 효과)

  • Lee, Jung Bok;Choi, So Young
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.5
    • /
    • pp.713-722
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the effects of pelvic floor muscle exercise using electric stimulation and biofeedback on maximum pressure of vaginal contraction, vaginal contraction duration and sexual function in women who have had vaginal rejuvenation. Methods: The research design was a non-equivalent control group non-synchronized design study. Participants in this study were women who had vaginal rejuvenation at C obstetrics and gynecology hospital. The 15 participants in the experimental group were given pelvic floor muscle exercise using electric stimulation and biofeedback and the 15 participants in the control group received self pelvic floor muscle exercise. Results: For maximum pressure of vaginal contraction, the experimental group showed a statistically significant increase compared to than the control group (t=5.96, p <.001). For vaginal contraction duration, the experimental group also showed a statistically significant increase compared to the control group (t=3.23, p =.003). For women' s sexual function, the experimental group showed a significant increase when compared to the control group in total sexual function scores (t=3.41, p =.002). Conclusion: The results indicate that pelvic floor muscle exercise with electric stimulation and biofeedback after vaginal rejuvenation is effective in strengthening vaginal contraction pressure, vaginal contraction and that it also positively functions to increase women's sexual function.

Effect of Progressive Muscle Relaxation using Biofeedback on Perceived Stress, Stress Response, Immune Response and Climacteric Symptoms of Middle-Aged Women (바이오피드백을 이용한 점진적 근육이완이 중년여성의 지각된 스트레스, 스트레스반응, 면역반응 및 갱년기 증상에 미치는 효과)

  • 정인숙
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.2
    • /
    • pp.213-224
    • /
    • 2004
  • Purpose: This study was aimed to evaluate the effect of progressive muscle relaxation training using biofeedback on perceived stress, stress response, immune response and climacteric symptoms, Method: This was a crossover, pre-post test design, The study subjects are 36 middle-aged women who were selected at 2 public health centers, The independent variable was Biofeedback training for 4 weeks, twice a week and home training for 4 weeks, Dependent variables were perceived stress, stress response, immune response, and climacteric symptoms measured with Hildtch's scale (1996), Result: Progressive muscle relaxation training using biofeedback was not effective in reducing perceived stress, but it was shown to be effective in reducing physiological stress responses such as pulse rate and EMG, Though blood pressure and skin conductance were repeatedly down, and skin temperature slowly increased, there were no statistically significant differences. Progressive muscle relaxation training using biofeedback was not effective in reducing serum cortisol, enhancing immune responses, or decreasing climacteric symptoms. Conclusion: The findings point to a pressing need for further, well-controlled and designed research with consideration in selection of subjects and instruments, frequency of measurements, the sampling method, and intervention modalities.

Effects of Cervical Stabilization Exercise Using Pressure Biofeedback on Neck Pain, Forward Head Posture and Acoustic Characteristics of Chronic Neck Pain Patients with Forward Head Posture (앞쪽머리자세가 있는 만성 목통증 환자에게 압력 바이오피드백 장비를 이용한 목안정화운동 적용이 목통증과 앞쪽머리자세, 음향학적 특성 변화에 미치는 효과)

  • Kim, Gi-Chul;HwangBo, Pil-Neo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.121-129
    • /
    • 2019
  • PURPOSE: This study was conducted to measure the effects of cervical stabilization exercises on neck pain, forward head posture, and the acoustic characteristics frequency and amplitude modulation of patients with chronic neck pain caused by forward head posture using pressure biofeedback. METHODS: 20 patients with chronic neck pain and voice disorders presenting at the S Exercise Center in Daegu, Korea, were included in the study. A cervical stabilization exercise program of 50 minutes per session was performed three times a week for eight weeks. Pressure biofeedback was utilized to determine the impact of the exercises on neck pain, forward head posture, and the acoustic characteristics of the patients. The measurements were taken prior to and after the intervention to determine any changes. RESULTS: A significant improvement in neck pain, craniovertebral angle and the acoustic characteristics frequency and amplitude modulation of the patients was demonstrated after the intervention (p<.05). CONCLUSION: Cervical stabilization exercises were demonstrated to have a significantly positive effect on neck pain, forward head posture, and vocalization stability in patients with chronic neck pain in the current study based on measurements taken using a pressure biofeedback system. This indicates that an improvement in forward head posture positively impacts postural stability and vocalization. Future studies investigating a greater range of interventions designed to improve neck pain and acoustical effects in patients with chronic neck pain and forward head posture patients are warranted.

The Correlation of the Pressure of Biofeedback Unit and Lumbopelvic Motion During Straight Leg Raising in Healthy Subjects (정상인에서 수동적인 뻗은다리올림 시 생체되먹임 장치의 압력과 허리골반 움직임의 상관관계)

  • Jung, Do-young
    • Physical Therapy Korea
    • /
    • v.25 no.3
    • /
    • pp.12-18
    • /
    • 2018
  • Background: Passive straight leg raising (PSLR) is the common clinical test to measure of hamstring muscle length. Hip flexion angle contributes to change the lumbopelvic rotation during PSLR. Pressure biofeedback unit (PBU) is commonly used to detect lumbopelvic movement during lower limb movements. Thus, there may be the relationship between pressure of PBU and lumbopelvic motion during PSLR. Objects: The objective of this study was to determine the relationship between pressure of PBU and lumbopelvic motion during PSLR. Methods: Thirty two subjects participated in this study. A three-dimensional motion analysis system were used to measure the lumbopelvic angle during PSLR, while recording the pressure of PBU according to angle of PSLR by 10 degree increments. Pearson product moment correlations and linear regression analysis were used to describe the relationship between variables. Results: The results showed that there was a significant relationship between the lumbopelvic and angle of PSLR (Pearson's r=.83, p<.05), between the pressure of PBU and angle of PSLR (Pearson's r=.75, p<.05), and between lumbopelvic motion and pressure of PUB (Pearson's r=.83, p<.05). Linear regression equation using lumbopevic angle as an independent factor was as follows: Pressure of PBU = 47.35 + (2.55 ${\times}$ angle of lumbopelvic motion) ($R^2=.69$, p<.05). Conclusion: Results of the present study indicate that pressure of PBU can be used to indirectly detect the amounts of lumbobevic motion during muscle length test or stretching of hamstring.