• Title/Summary/Keyword: Pressure alleviation

Search Result 17, Processing Time 0.023 seconds

Effects of Deep Cervical Flexors Strengthening Exercise on Cervical-Shoulder Angle, Disability index and pain and in Patients with Chronic Neck Pain (깊은목굽힘근 강화운동이 만성 목통증 환자의 통증과 목-어깨각도, 장애지수 및 통증에 미치는 영향)

  • Kim, Jin-young
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.33-37
    • /
    • 2015
  • Background: The purpose of this study on the effects of deep cervical flexors strengthening exercise to forward head posture and pain of neck in patients with chronic neck pain. Method: We selected 30 subjects among neck pain patients and carried out measurements. The subjects' forward head posture was measured including head tilt angle (HTA), neck flexion angle (NFA) and forward shoulder angle (FSA), neck disability index (NDI), numeric rating scale (NRS). The subjects underwent deep cervical flexors muscle strengthening with pressure bio-feedback device for 4 weeks. Then, after intervention, the subjects' forward head posture was measured again. It was performed Wilcoxon signed-ranks test for confirming the effect of deep cervical flexor muscles strengthening exercise. Results: As a result of comparison of measurements before and after intervention, we found that there were statistically significant improvement in the subjects' NDI, NRS and forward head posture including head tilt angle, neck flexion angle and forward shoulder angle. Conclusion: We concluded that deep cervical flexors strengthening exercise has the effect of alleviation of neck pain patients and is effective for forward head posture.

  • PDF

New Control Scheme for the Wind-Driven Doubly Fed Induction Generator under Normal and Abnormal Grid Voltage Conditions

  • Ebrahim, Osama S.;Jain, Praveen K.;Nishith, Goel
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.10-22
    • /
    • 2008
  • The wind-driven doubly fed induction generator (DFIG) is currently under pressure to be more grid-compatible. The main concern is the fault ride-through (FRT) requirement to keep the generator connected to the grid during faults. In response to this, the paper introduces a novel model and new control scheme for the DFIG. The model provides a means of direct stator power control and considers the stator transients. On the basis of the derived model, a robust linear quadratic (LQ) controller is synthesized. The control law has proportional and integral actions and takes account of one sample delay in the input owing to the microprocessor's execution time. Further, the influence of the grid voltage imperfection is mitigated using frequency shaped cost functional method. Compensation of the rotor current pulsations is proposed to improve the FRT capability as well as the generator performance under grid voltage unbalance. As a consequence, the control system can achieve i) fast direct power control without instability risk, ii) alleviation of the problems associated with the DFIG operation under unbalanced grid voltage, and iii) high probability of successful grid FRT. The effectiveness of the proposed solution is confirmed through simulation studies on 2MW DFIG.

Transonic buffet alleviation on 3D wings: wind tunnel tests and closed-loop control investigations

  • Lepage, Arnaud;Dandois, Julien;Geeraert, Arnaud;Molton, Pascal;Ternoy, Frederic;Dor, Jean Bernard;Coustols, Eric
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.2
    • /
    • pp.145-167
    • /
    • 2017
  • The presented paper gives an overview of several projects addressing the experimental characterization and control of the buffet phenomenon on 3D turbulent wings in transonic flow conditions. This aerodynamic instability induces strong wall pressure fluctuations and therefore limits flight domain. Consequently, to enlarge the latter but also to provide more flexibility during the design phase, it is interesting to try to delay the buffet onset. This paper summarizes the main investigations leading to the achievement of open and closed-loop buffet control and its experimental demonstration. Several wind tunnel tests campaigns, performed on a 3D half wing/fuselage body, enabled to characterize the buffet aerodynamic instability and to study the efficiency of innovative fluidic control devices designed and manufactured by ONERA. The analysis of the open-loop databases demonstrated the effects on the usual buffet characteristics, especially on the shock location and the separation areas on the wing suction side. Using these results, a closed-loop control methodology based on a quasi-steady approach was defined and several architectures were tested for various parameters such as the input signal, the objective function, the tuning of the feedback gain. All closed-loop methods were implemented on a dSPACE device able to estimate in real time the fluidic actuators command calculated mainly from the unsteady pressure sensors data. The efficiency of delaying the buffet onset or limiting its effects was demonstrated using the quasi-steady closed-loop approach and tested in both research and industrial wind tunnel environments.

Potential Influence of Climate Change on Shellfish Aquaculture System in the Temperate Region

  • Jo, Qtae;Hur, Young Baek;Cho, Kee Chae;Jeon, Chang Young;Lee, Deok Chan
    • The Korean Journal of Malacology
    • /
    • v.28 no.3
    • /
    • pp.277-291
    • /
    • 2012
  • Aquaculture is challenged by a number of constraints with future efforts towards sustainable production. Global climate change has a potential damage to the sustainability by changing environmental surroundings unfavorably. The damaging parameters identified are water temperature, sea level, surface physical energy, precipitation, solar radiation, ocean acidification, and so on. Of them, temperature, mostly temperature elevation, occupies significant concern among marine ecologists and aquaculturists. Ocean acidification particularly draws shellfish aquaculturists' attention as it alters the marine chemistry, shifting the equilibrium towards more dissolved CO2 and hydrogen ions ($H^+$) and thus influencing signaling pathways on shell formation, immune system, and other biological processes. Temperature elevation by climate change is of double-sidedness: it can be an opportunistic parameter besides being a generally known damaging parameter in aquaculture. It can provide better environments for faster and longer growth for aquaculture species. It is also somehow advantageous for alleviation of aquaculture expansion pressure in a given location by opening a gate for new species and aquaculture zone expansion northward in the northern hemisphere, otherwise unavailable due to temperature limit. But in the science of climate change, the ways of influence on aquaculture are complex and ambiguous, and hence are still hard to identify and quantify. At the same time considerable parts of our knowledge on climate change effects on aquaculture are from the estimates from data of fisheries and agriculture. The consequences may be different from what they really are, particularly in the temperature region. In reality, bivalves and tunicates hung or caged in the longline system are often exposed to temperatures higher than those they encounter in nature, locally driving the farmed shellfish into an upper tolerable temperature extreme. We review recent climate change and following environment changes which can be factors or potential factors affecting shellfish aquaculture production in the temperate region.

Effects of musical intervention on the fear and anxiety reduction during scaling (치석제거 시 음악중재가 공포 및 불안 감소에 미치는 영향)

  • Nam, Yong-Ok;Ju, On-Ju;Lee, Kwang-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.395-404
    • /
    • 2017
  • Objectives: The purpose of this study was to identify the effects of music intervention on the patient's fear and anxiety during scaling. Methods: 360 patients who had visited W University dental hygiene laboratory were selected as study subjects and divided into experiment group and control group. Results: Study results showed that the control group (71.9%) and the experimental group (75.1%) had experiences avoiding dental treatment due to fear. In the control group (37.6%) and experimental group (40.6%), the highest influencing factor was the sound of machine and followed by pain. The experimental group preferred classical music, followed by pop songs, trot music and instrumental music. In the experimental group (83.3%), fear and anxiety were alleviated by music, and 77.9% of the patients mentioned they would recommend music for scaling to other patients. There was an interaction effect (p=0.014) between the groups before and after the measurement of the lowest blood pressure. There was a significant difference in pulse before and after pulse measurement (p=0.000). There was a significant difference in respiration between groups (p=0.042) and before and after respiration (p=0.030). Conclusions: Study results showed that music intervention that utilizes music during scaling showed significant effects on the alleviation of fear and anxiety, affecting Pulse number among vital signs. Therefore, more systematic program is to be required to alleviate dental fear and anxiety with music therapy not only for scaling, but also for dental clinic in the future.

Sparing effect of tramadol, lidocaine, dexmedetomidine and their combination on the minimum alveolar concentration of sevoflurane in dogs

  • El-Hawari, Sayed Fathi;Oyama, Norihiko;Koyama, Yukako;Tamura, Jun;Itami, Takaharu;Sano, Tadashi;Yamashita, Kazuto
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.53.1-53.9
    • /
    • 2022
  • Background: Problems associated with using inhalational anaesthesia are numerous in veterinary anaesthesia practice. Decreasing the amount of used inhalational anaesthetic agents and minimising of cardiorespiratory disorders are the standard goals of anaesthetists. Objective: This experimental study was carried out to investigate the sparing effect of intravenous tramadol, lidocaine, dexmedetomidine and their combinations on the minimum alveolar concentration (MAC) of sevoflurane in healthy Beagle dogs. Methods: This study was conducted on six beagle dogs. Sevoflurane MAC was determined by the tail clamp method on five separate occasions. The dogs received no treatment (control; CONT), tramadol (TRM: 1.5 mg kg-1 intravenously followed by 1.3 mg kg-1 h-1), lidocaine (LID: 2 mg kg-1 intravenously followed by 3 mg kg-1 h-1), dexmedetomidine (DEX: 2 ㎍ kg-1 intravenously followed by 2 ㎍ kg-1 h-1), and their combination (COMB), respectively. Cardiorespiratory variables were recorded every five minutes and immediately before the application of a noxious stimulus. Results: The COMB treatment had the greatest sevoflurane MAC-sparing effect (67.4 ± 13.9%) compared with the other treatments (5.1 ± 25.3, 12.7 ± 14.3, and 40.3 ± 15.1% for TRM, LID, and DEX treatment, respectively). The cardiopulmonary variables remained within the clinically acceptable range following COMB treatment, although the mean arterial pressure was higher and accompanied by bradycardia. Conclusions: Tramadol-lidocaine-dexmedetomidine co-infusion produced a remarkable sevoflurane MAC-sparing effect in clinically healthy beagle dogs and could result in the alleviation of cardiorespiratory depression caused by sevoflurane. Cardiorespiratory variables should be monitored carefully to avoid undesirable side effects induced by dexmedetomidine.

건물의 배수 및 통기시스템: 배관 내부압력의 능동적인 제어

  • Gormly, Michael;Swaffield, John. A.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.9
    • /
    • pp.41-51
    • /
    • 2010
  • 건물의 배수 및 통기시스템에서 나타나는 현상중에 확실한 내용이 아직 밝혀지지 않은 부분이 몇 가지 남아 있다. 이것은 19세기 말엽의 근대 위생공학의 시작 단계에서부터 잘 알려진 사실이다. 건물의 배수 및 통기시스템 운용에 대한 내용은 일반 공학과 특정 유체역학의 범위 내에서 가장 잘 이해할 수 있다. 건물의 배수 및 통기시스템의 운영에 종사했던 초기의 기술진들은 이러한 점을 잘 알고 있었으며 유체역학에 적합하게 응용한 많은 사례를 확인할 수 있었다. 제2차 세계대전이 끝나고 이에 대한 많은 연구가 진행되어 왔으며 특히 유럽에서 시작된 전후 재건 붐을 통해 배수 및 통기시스템의 설계에 좀 더 효율적인 접근이 진척되게 되었다. 이러한 배수시스템의 중심에는 배수관 내부의 오염된 공기가 배수구 또는 위생기구를 통하여 주거 공간으로 유입되는 것을 방지하는 트랩(Water Trap)이 있다. 배수트랩의 주요 기능인 봉수는 일반적으로 깊이가 40 mm에서 50 mm 정도로 위생기구의 종류에 따라 봉수의 깊이는 다소 차이가 있다. 배수관내 공기의 흐름이 중요한 것처럼 트랩의 봉수 메커니즘이 중요하기 때문에 이 메커니즘을 소홀히 여긴다면 안전한 배수시스템의 운영을 기대하기는 어렵다. 배수관 내의 공기의 흐름은 배수에 의해 유입되거나 또는 배출된다. 배수관에서 내부 압력의 불규칙한 변화로 인하여 야기되는 불안정한 배수의 흐름은 트랩의 봉수를 파괴하고 나아가 주거공간으로 오염된 공기가 새어 나갈 수 있는 통로를 제공하게 된다. 관내압력의 천이는 이로 인한 문제가 발생할 가능성이 있는 위치에 그 압력을 완화할 수 있는 장치를 설계단계에 반영하여 적용함으로써 제어할 수 있다. 건물 내부에 상당한 길이의 통기배관을 설치하는 것은 배관의 마찰손실로 인하여 천이 현상을 효과적으로 제어할 수 있는 확실한 방법이 되지는 못한다. 그렇지만 통기밸브를 설치하는 것과 같이 배수관 내로 공기를 공급해주는 유입구를 건물 내부에 분산 설치하는 것이 효율적인 통기방식이 될 수 있고, 정압 천이로 인한 위험을 줄여줄 수 있다. 통기밸브는 정압 발생의 원인이 되지 않으며 단지 정압에 반응하여 더욱 기밀하게 닫히며, 약화된 압력파를 반사할 뿐이다. 고층 건물에서 배수입상관과 평행하게 설치된 통기입상관(Parallel Vent Pipe)의 경우 극히 일부분의 정압 천이 현상을 완화할 수 있다. (통기 배관의 직경이 배수 입상배관과 동일한 경우 대략 1/3 정도임), 그러므로 정압의 천이로 인한 압력 파동은 배수 시스템의 나머지 부분을 통해 전파되어 배수 트랩에 영향을 미치게 된다. 정압의 천이가 예상되는 위치에 정압천이 완화 장치(Positive Air Pressure Transient Alleviation Device)를 사용하면 배관 내부압력의 급격한 상승을 방지하여 연결된 트랩의 봉수를 보호할 수 있다. 이렇게 되면 순간적으로 발생하는 배관내 압력의 급등 현상을 90% 정도까지 완화 시킬 수 있다. 경험적으로 배수시스템에서 배관이 완전하게 막혀 과도한 정압이 발생하는 경우는 거의 없다. 이러한 경우에는 가장 낮은 위치에 있는 배수 트랩의 봉수가 깨지면서 자연스럽게 배수시스템의 압력이 해소되게 된다. 이러한 사례는 통기 방식과 상관없이 발생할 수 있다. 실제와 유사한 시뮬레이션을 통하여 통기 밸브(Air Admittance Valves)는 전면 통기 시스템 (Fully Vented System)에서 최소한 트랩의 봉수 보호용으로 적합한 것이 확인 되었다. 어떤 경우 에는 고층 건물에 더욱 적합하다는 것을 확인할 수 있었다. 부압 해소용으로 통기밸브를 이용하고 정압완화용으로 정압 완화장치(PAPAs: Positive Air Pressure Transient Attenuators)를 사용하는 전면적 능동 제어시스템(Fully Engineered Designed Active Control System)이 사용자에게 육안으로는 확인하지 못하는 기능을 보장하면서 배수 시스템의 안전과 효율성에 대한 효과적인 방법을 제공하고 있다.

  • PDF