• 제목/요약/키워드: Pressure Tank

검색결과 836건 처리시간 0.028초

Fabrication of Hollow Cylinder Tank Using Superplastic Forming Technology

  • Lee, Ho-Sung;Yoon, Jong-Hoon;Yi, Yeong-Moo
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.799-803
    • /
    • 2008
  • The possibility of manufacturing titanium hollow cylinder tank for ramjet engine was demonstrated with superplastic forming of subscale article. An innovative manufacturing method to produce complex configuration from titanium multi-sheets by low hydrostatic pressure was presented. Finite element analysis on superplastic blow forming process has been carried out in order to improve the forming process when manufacturing subscale hollow cylinder structure using Ti-6Al-4V multi-sheets. The simulation focused on the reduction of forming time and obtaining finally required shape throughout investigating the deformation mode of sheet according to the forming conditions and die geometry. From pre-sized titanium sheets, near net shape of hollow cylinder tank is obtained by superplastic blow forming conducted using gas pressure of 15bar at 1148K. The result shows that the manufacturing method with superplastic forming of multi-sheets of titanium alloy has been successful for near net shape forming of subscale hollow cylinder tank of ramjet engine.

  • PDF

3차 상태방정식을 이용한 수소 충전 온도 거동 모사 (Simulation of Temperature Behavior in Hydrogen Tank During Refueling Using Cubic Equations of State)

  • 박병흥
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.385-394
    • /
    • 2019
  • The analysis of temperature behavior of a hydrogen tank during refueling is of significance to clarify the safety of the compressed hydrogen storage in vehicles since the temperature at a tank rises with inflow of hydrogen. A mass balance and an energy balance were combined to obtain analytical model for temperature change during the hydrogen refueling. The equation was coupled to Peng-Robinson-Gasem (PRG) equation of state (EOS) for hydrogen. The PRG EOS was adopted after comparison with other four different cubic EOSs. A parameter of the model was determined to fit data from experiments of various inlet flow rates and temperatures. The temperature and pressure change with refueling time were obtained by the developed model. The calculation results revealed that the extent of precooling was more effective than the flow rate control.

강제석유저장탱크(KS B 6225)의 내진설계기준 개선 안 (Seismic Design Guidelines for Welded Steel Oil Storge Tank (KS B 6225))

  • 박종률;오택열
    • 대한기계학회논문집A
    • /
    • 제26권3호
    • /
    • pp.544-552
    • /
    • 2002
  • Recommended seismic design guide for the flat bottom vortical-cylindrical oil storage tanks in KS B 6225 is presented. Under earthquake excitations, the hydrodynamic pressure exerted on the tank walls produces overturning moment which may cause either a failure of the anchors or a buckling of the tank shell near its base. The basis for establishing design loads due to hydrodynamic pressure is described including seismic zone risk map in Korea, zone coefficients and the essential facilities factor. This procedure for calculating applied compressive stress on the shell base subjecting to seismic load and for estimating the allowable buckling stress is described.

강제 석유 저장 탱크(KS B 6225)의 내진 설계 기준 개선 안 (Seismic Design Guidelines for Welded Steel Oil Storge Tank (KS B 6225))

  • 박종률;오택열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.166-173
    • /
    • 2001
  • Recommended seismic design guide for the flat bottom vertical-cylindrical oil storage tanks in KS B 6225 is presented. Under earthquake excitations, the hydrodynamic pressure exerted on the tank walls produces overturning moment which may cause either a failure of the anchors or a buckling of the tank shell near its base. The basis for establishing design loads due to hydrodynamic pressure is described including seismic zone risk map in Korea, zone coefficients and the essential facilities factor. This procedure for calculating applied compressive stress on the shell base subjecting to seismic load and for estimating the allowable buckling stress is described.

  • PDF

액체저장탱크의 내진설계 프로그램 개발 (Seismic Design Program for Oil Storage Tank)

  • 박종률;오택열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.551-555
    • /
    • 1997
  • IJnder earthquake excitations, the hydrodynamic pressure exerted on the flat bottom vertical-cylindrical oil storage tank walls produces overturning moment which may cause either a failure of the anchors or a buckling of the tank shell near its base. The basis for establishing design loads due to hydrodynamic pressure is described including seismic zone risk map in Korea. zone coefficients and the essential facilities factor. This procedure for calculating applied compressive stress on the shell base subjecting to seismic load and for estimating the allowable buckling stress is described. And seismic design program for the tanks is presented.

  • PDF

수소 잔존 용량에 따른 수소 탱크 충전 시간 및 온도 변화 예측 (Prediction of Changes in Filling Time and Temperature of Hydrogen Tank According to SOC of Hydrogen)

  • 이현우;오동현;서영진
    • 한국수소및신에너지학회논문집
    • /
    • 제31권4호
    • /
    • pp.345-350
    • /
    • 2020
  • Hydrogen is an green energy without pollution. Recently, fuel cell electric vehicle has been commercialized, and many studies have been conducted on hydrogen tanks for vehicles. The hydrogen tank for vehicles can be charged up to 70 MPa pressure. In this study, the change in filling time, pressure, and temperature for each hydrogen level in a 59 L hydrogen tank was predicted by numerical analysis. The injected hydrogen has the properties of real gas, the temperature is -40℃, and the mass flow rate is injected into the tank at 35 g/s. The initial tank internal temperature is 25℃. Realizable k-epsilon turbulence model was used for numerical analysis. As a result of numerical analysis, it was predicted that the temperature, charging time, and the mass of injected hydrogen increased as the residual capacity of hydrogen is smaller.

응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리 (The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank)

  • 김동하;이수영;정의택
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

내장형 레귤레이터 및 솔레노이드 개발 (Development of In-tank Pressure Regulator and Solenoid Valve)

  • 이준혁;임태호;김경남;심상학
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.188-191
    • /
    • 2007
  • This paper shows the Development of In-tank pressure regulator and Solenoid Valve used in FCV(Fuel Cell Vehicle). We have developed new type of Regulator and Solenoid through analysis of the structure and characteristics of component of FCS(Fuel Cell System) from the advanced technology. Now it is possible to localize the component by making use of the development of Regulator and Solenoid made by us. Regulator and Solenoid is a equipment to control hydrogen pressure supplied into a stack. Therefore, outlet pressure, a flow of fluid and temperature are important parameters according to a inlet pressure. And leak test, endurance test and burst test should be done to guarantee the performance and safety of Regulator and Solenoid used in the fuel of high pressure. Also, Hydrogen friendly materials are applied to inner parts of the Regulator, Solenoid and weight reduction is done to cost saving in part not related to performance. As a result, we have proven the good performance and reliability in endurance of Regulator, Solenoid and will make an development in performance as well as durability to ensure industrialization.

  • PDF

Simulation, analysis and optimal design of fuel tank of a locomotive

  • Yousefi, A. Karkhaneh;Nahvi, H.;Panahi, M. Shariat
    • Structural Engineering and Mechanics
    • /
    • 제50권2호
    • /
    • pp.151-161
    • /
    • 2014
  • In this paper, fuel tank of the locomotive ER 24 has been studied. Firstly the behavior of fuel and air during the braking time has been investigated by using a two-phase model. Then, the distribution of pressure on the surface of baffles caused by sloshing has been extracted. Also, the fuel tank has been modeled and analyzed using Finite Element Method (FEM) considering loading conditions suggested by the DIN EN 12663 standard and real boundary conditions. In each loading condition, high stressed areas have been identified. By comparing the distribution of pressure caused by sloshing phenomena and suggested loading conditions, optimization of the tank has been taken into consideration. Moreover, internal baffles have been investigated and by modifying their geometric properties, search of the design space has been done to reach the optimal tank. Then, in order to reduce the mass and manufacturing cost of the fuel tank, Non-dominated Sorting Genetic Algorithm (NSGA-II) and Artificial Neural Networks (ANNs) have been employed. It is shown that compared to the primary design, the optimized fuel tank not only provides the safety conditions, but also reduces mass and manufacturing cost by %39 and %73, respectively.

멤브레인식 LNG 저장탱크용 PC 외부탱크의 강도안전성에 관한 연구 (A Study on the Strength Safety of the Prestressed Concrete Outer Tank for a Membrane LNG Storage Tank)

  • 김청균;김도현
    • 한국가스학회지
    • /
    • 제13권1호
    • /
    • pp.21-27
    • /
    • 2009
  • 본 논문은 특별한 주름을 갖는 멤브레인 패널로 제작한 LNG 저장탱크용 예응력 콘크리트(PC) 외부탱크에 대한 강도안전성 연구를 수행하였다. 강도안전성을 유한요소법으로 해석하기 위해 멤브레인 패널로 제작한 내부탱크가 파손되면서 저장된 LNG가 PC 외부탱크로 누설되었다고 가정한다. 본 연구는 누설 LNG에 의해 발생하는 유체정압과 자중량, 온도차 하중, PC 구조물의 자중량, 증발가스 압력에 의해 형성되는 5가지의 복합하중에 대해 외부탱크에 작용하는 응력과 변형거동을 해석하였다. FEM 해석결과에 의하면, 멤브레인으로 제작된 내부탱크로부터 LNG가 누설되어도 200,000$m^3$의 저장용량을 갖는 LNG 외부탱크(PC 콘크리트 구조물)는 충분한 강도안전성을 갖지만, 누설 LNG에 의한 초저온 하중이 더욱 증가하게 되면 PC 외부탱크 구조물의 강도안전성은 계속 떨어지고, 궁극적으로 외부탱크의 붕괴로 발전할 수 있다는 점에 주의해야 한다.

  • PDF