• 제목/요약/키워드: Pressure Regulator

검색결과 148건 처리시간 0.024초

Plasma control Using a Linear Quadratic Regulated RF Impedance Match Process

  • Kim, Byung-Whan;Park, Jang-Hyun;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.31.2-31
    • /
    • 2001
  • A real-time control strategy is presented for plasma control Rather than in-situ plasma variables, this is based on realtime measurements of two electrical positions that correspond to two match motors. Using the rf match monitor system, the positions were collected. The process of impedance matching was identified with variations in process factors, including rf power, pressure, and O$_2$ flow rate. A state-space model was obtained basing on autoregressive moving average model. For this model, a linear quadratic regulator was designed and applied. Simulation results revealed that match positions could accurately be regulated to follow certain positions arbitrarily chosen.

  • PDF

가정용 LPG 저압조정기의 경년특성에 관한 연구 (Aging Characteristics of Low Pressure LPG Regulators for Domestic Use)

  • 김영규;권정락
    • 한국가스학회지
    • /
    • 제3권1호
    • /
    • pp.58-63
    • /
    • 1999
  • 가정용 LPG 저압조정기의 사용경과에 따른 성능특성과 사용수명을 평가하기 위하여 실험적 연구를 수행하였다. 실험결과에 의하면 조정기의 안전장치 작동압력은 사용경과 1년부터 분출개시압력값과 정지압력값을 이탈하였고, 조정압력과 폐쇄압력은 사용경과 7${\~}$8년부터의 조정기에서 기준값을 현저하게 벗어났다. 스프링과 다이어프램은 사용한지 5${\~}$6년이 경과하면서 재료특성이 저하하였다. 따라서 LPG 저압조정기는 약 6년 정도의 사용수명을 갖고 있는 것으로 평가된다. 그러나 사용자의 안전확보와 사고예방을 위해서 5년이 경과하면 조정기에 이상이 없더라도 교체하는 것이 바람직하다.

  • PDF

스마트 가스 계량기 압력 데이터 기반 누출 판단 기법 개발 (Development of Leakage Judgment Technique based on Pressure Data of Smart Gas Meter)

  • 김정훈;오정석;이진한
    • 한국가스학회지
    • /
    • 제27권2호
    • /
    • pp.57-64
    • /
    • 2023
  • 가스계량기의 검침방식이 발전하면서 원격검침이 가능한 스마트 가스 계량기(누출점검용 계량기 및 다기능 안전 계량기)가 사용되고 있다. 이러한 계량기는 부가기능으로 수집하는 유량 및 압력 데이터를 활용하여 누출 판단을 하는 기능이 있다. 유량 데이터를 이용한 누출판단 기능은 실제 현장에서 유효한 사례가 있지만 압력 데이터 기반 누출 판단 기준은 누출로 인한 압력 값 변화뿐만 아니라 여러 요인(정압기 압력 크기, 인접 계량기 연계, 인접 주택 사용량, 계량기 위치 등)으로 압력 크기 변화(레벨)가 있는 문제점이 있다. 본 논문에서는 스마트 가스계량기에서 수집되는 압력데이터를 활용하여 누출여부를 판단 할 수 있는 기법으로 압력 데이터 전처리 방법과 누출 여부 관련 압력 값 범위 기준, 누출판단 기법 및 적용 사례 검증을 통해 개발하였다.

고혈압모델에서 귀혈위자극기의 혈압강하 효과 (Effect of the Auriculoelectrostimulator on Blood Pressure In Hypertensive Rat Models)

  • 김희영;김성옥;황혜정;함대현;이권순;김순택;심인섭;이혜정
    • 동의생리병리학회지
    • /
    • 제18권3호
    • /
    • pp.724-728
    • /
    • 2004
  • Several studies have shown that a low frequency stimulation can depress blood pressure in hypertension. We had developed a new auriculoelectrostimulator as an electronic blood pressure regulator for simple and easy stimulation. The new auriculoelectrostimulator was employed in hypertensive rat model induced by immobilization stress, diabetic and essential hypertensive rat models. Rats were stimulated by auriculoelectrostimulator at ear acupoint (Ear point for hypertension) bilaterally. Ear stimulation by auriculoelectrostimulator significantly decreased blood pressure in all hypertensive rat models and inhibited the increase of heart rates in stressed and spontaneous hypertensive rats. The results showed that auriculoelectrostimulator had depressive effects on hypertension in rat hypertensive models, suggesting that it is useful in treatment of hypertension.

폐쇄성 수면 무호흡 증후군과 폐동맥 고혈압에서 엔도텔린-1의 역할 (The Role of Endothelin-1 in Obstructive Sleep Apnea Syndrome and Pulmonary Hypertension)

  • 최영미
    • 수면정신생리
    • /
    • 제17권2호
    • /
    • pp.69-74
    • /
    • 2010
  • Obstructive sleep apnea syndrome is associated with significant cardiovascular morbidity and increased mortality. However, it was controversial whether obstructive sleep apnea syndrome could cause pulmonary hypertension. The controversy was resolved by several studies that have shown pulmonary hypertension in 20% to 40% of patients with obstructive sleep apnea syndrome without underlying other cardiopulmonary diseases and reductions in pulmonary arterial pressure in patients with obstructive sleep apnea syndrome after treatment with nocturnal continuous positive airway pressure. Recent studies provide strong evidence for endothelial dysfunction in obstructive sleep apnea syndrome and pulmonary hypertension. Endothelin-1 is a 21 amino acid peptide with diverse biologic activity such as highly potent vasoconstrictor and mitogen regulator that may play a key role in obstructive sleep ap-nea syndrome and pulmonary hypertension. Continuous positive airway pressure therapy is moderately effective in reducing pulmonary arterial pressure. Further researches are needed to assess the therapeutic efficacy of pharmacologic therapy with agents that inhibit the action of endothelin-1 in obstructive sleep apnea syndrome patients with pulmonary hypertension.

  • PDF

HCNG 엔진용 연료시스템의 적용성 평가 (Applicability of Fuel Supply System for HCNG Engine)

  • 이성원;임기훈;박철웅;최영;김창기;이장희
    • 한국자동차공학회논문집
    • /
    • 제21권2호
    • /
    • pp.146-153
    • /
    • 2013
  • CNG buses has contributed to improve air quality in cities. But it is difficult to meet the next emission regulations such as EURO-VI without the help of additional post-processing device. Hydorgen has higher flame speed and lower combustion temperature that make it thermal efficiency increase with leaner operation. Using hydrogen natural gas blend (HCNG) fuel is promising technology which can reduce $NO_x$ and $CO_2$ emissions for a natural gas vehicle. However, fuel flow rate of HCNG should be increased since hydrogen's energy density per volume is much smaller than natural gas. In the present study, the characteristics of fuel supply system and its applicability were evaluated in a heavy duty natural gas engine. The results showed that the potential of fuel pressure regulator and fuel metering valve had enough capacity with HCNG. Employed mixer did not affect the distribution characteristics of mixture.

Application of LQR for Phase-Locked Loop Control Systems

  • Khumma, Somyos;Benjanarasuth, Taworn;Isarakorn, Don;Ngamwiwit, Jongkol;Wanchana, Somsak;Komine, Noriyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.520-523
    • /
    • 2004
  • A phase-locked loop control system designed by using the linear quadratic regulator approach is presented in this paper. The system thus designed is optimal system when system is in locked state and the parameter value of loop filter which is an active PI filter can be obtained easily. By considering the structure of loop filter of phase-locked loop is included in the process to be controlled, a type 1 servo system can be constructed when voltage control oscillator is considered as an integrator. The integral gain of the proposed system obtained by linear quadratic regulator approach can be used as an optimal value to design the parameter of loop filter. The implemented result in controlling the second-order lag pressure process by using the proposed scheme show that the system response is fast with no overshoot and no steady-state error. Furthermore, the experimental results are also shown in term of output disturbance effect rejection, tracking and process parameter changed.

  • PDF

KSR-III 추진기관 공급계 PTA-I 종합수류시험 (PTA-I test of KSR-III Propulsion Feeding System)

  • 권오성;정영석;조인현;정태규;오승협
    • 한국추진공학회지
    • /
    • 제7권3호
    • /
    • pp.22-29
    • /
    • 2003
  • KSR-III 추진기관 공급계는 각종 배관류, 밸브류 및 이를 제어하는 제어기로 구성되어 있으며, 엔진으로 유입되는 추진제의 제어를 담당하고 있다. 이러한 공급계 시스템의 특성을 검증하고, 구성부품의 성능을 확인하기 위하여 PTA-I 수류시험을 실시하였다. PTA-I 시험설비는 엔진과 헬륨가압탱크를 제외한 공급계 전체와 지원설비로 이루어져 있다. PTA-I에서는 밸브, 제어기와 같은 단품에 대한 시스템 시험, 배관특성시험, 추진제 유량조절 시험, 배관부 압력 변동폭 및 주파수 특성 시험, 레귤레이터 성능 시험등을 수행하였다. PTA-I 시험을 통하여 구성단품에 대한 문제점을 발견하고 이를 수정보완 하였으며, 공급계 시스템의 설계 데이터와 시험데이터 비교를 통한 설계 검증을 완료하였다. PTA-I 시험의 결과는 PTA-II 및 연소시험을 수행하기 위한 시스템 구성에 적용하였다.

원전사고 평가를 위한 원전 사건유형분석 시스템(ETAS) 개발 (Development of the Event Type Analysis System (ETAS) for the Accident Evaluation in Nuclear Power Plants)

  • 최영환;김영미
    • 한국압력기기공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.35-39
    • /
    • 2009
  • In this study, Event Type Analysis System (ETAS) is developed for the accident evaluation in nuclear power plant. The ETAS system can be used in supporting regulator and/or operator under event situation in nuclear power plants. The ETAS system can categorize the all transient events to 3 categories such as Down-2000, Down-2173, and Slow Fluctuation. We develop the program structure for ETAS system and web-based ETAS system. The ETAS system will be used as sub module of Knowledge-Based Event Evaluation Network (K-EvENT) which is developing for the against the accident in nuclear power plants.

  • PDF