• Title/Summary/Keyword: Pressure Recovery

Search Result 916, Processing Time 0.025 seconds

Examination on Autonomous Recovery Algorithm of Piping System (배관 체계 자율 복구 알고리즘 비교, 분석 및 고찰)

  • Yang, Dae Won;Lee, Jeung-hoon;Shin, Yun-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.1-11
    • /
    • 2021
  • Piping systems comprising pumps and valves are essential in the power plant, oil, and defense industry. Their purpose includes a stable supply of the working fluid or ensuring the target system's safe operation. However, piping system accidents due to leakage of toxic substances, explosions, and natural disasters are prevalent In addition, with the limited maintenance personnel, it becomes difficult to detect, isolate, and reconfigure the damage of the piping system and recover the unaffected area. An autonomous recovery piping system can play a vital role under such circumstances. The autonomous recovery algorithms for the piping system can be divided into low-pressure control algorithms, hydraulic resistance control algorithms, and flow inventory control algorithms. All three methods include autonomous opening/closing logic to isolate damaged areas and recovery the unaffected area of piping systems. However, because each algorithm has its strength and weakness, appropriate application considering the overall design, vital components, and operating conditions is crucial. In this regard, preliminary research on algorithm's working principle, its design procedures, and expected damage scenarios should be accomplished. This study examines the characteristics of algorithms, the design procedure, and working logic. Advantages and disadvantages are also analyzed through simulation results for a simplified piping system.

Factors affecting Healing of Stage 2 Pressure Ulcer (2단계 욕창 치유에 영향을 주는 요인 분석)

  • Park, Kyung-Hee;Kim, Keum-Soon
    • Journal of Korean Critical Care Nursing
    • /
    • v.3 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • Purpose: This study was designed to identify the factors affecting healing of Stage 2 pressure ulcer in an acute care facility in Korea. Methods: 286 Stage 2 pressure ulcers of 145 patients were examined. Data were collected in the period between October $1^{st}$, 2006 and September $30^{th}$, 2007. Data were analyzed with Kaplan-Meier survival analysis for cumulative recovery rate of Stage 2 pressure ulcers. Cox proportional hazard model was used to examine effects of multiple variables simultaneously. Results: Out of 286 initial Stage 2 pressure ulcers, 204 (71.3%) pressure ulcers healed completely. The median time to heal was 15 days according to Kaplan-Meier survival analysis. Cox proportional hazard model showed that the Stage 2 pressure ulcers healed more quickly when pressure redistribution surfaces were used (p<.001, HR=2.184), patients were administered with vitamins (p= .038, HR=1.451), and the size of the pressure ulcers were small (${\leq}3.0cm^2$, p= .006, HR=1.765). Conclusion: The factors contributing to the healing of Stage 2 pressure ulcer in an acute care setting were the application of pressure redistribution surface, small ulcer size (${\leq}3.0cm^2$), and the administration of vitamins.

  • PDF

The Effects of Leg Elevation and Stretching Exercise on Monitored Anesthesia Care (MAC) with Dexmedetomidine (Dexmedetomidine 감시마취관리 환자의 회복 시 적용한 하지거상 및 말초운동의 효과)

  • Lee, Hee Jin;Lee, In Suk;Jung, Yeo Jin;Lee, Eun Jin;Park, Jeong On
    • Journal of Korean Clinical Nursing Research
    • /
    • v.22 no.3
    • /
    • pp.249-256
    • /
    • 2016
  • Purpose: The purpose of this study was to examine the effect of leg raising and peripheral excercise on recovery of the patients who were applied with dexmedetomidine for their dental surgery. Methods: There were two groups, the experimental group (n=35) and control group (n=35), in this study. We checked blood pressure, pulse rate, oxygen saturation, sedation level and symptoms such as dizziness and somnolence every 30 minutes. These parameters were assessed throughout the participants' recovery room stay. Leg raising and peripheral excercise were conducted in the experimental group in the recovery room. We have conducted chi-square test, Fisher's exact test, t-test, ANOVA, and ANCOVA to compare the measured parameters in both groups. Results: The experimental group showed a significant elevation of mean arterial blood pressure, and mitigation of somnolence, sedation and dizziness compared to the control group. Conclusion: Leg raising and peripheral exercise is effective to expedite recovery in the patients who were applied with dexmedetomidine for their dental surgery.

Recovery of Residual LiCl-KCl Eutectic Salts in Radioactive Rare Earth Precipitates (방사성 희토류 침전물내 잔류하는 LiCl-KCl 공융염의 회수)

  • Eun, Hee-Chul;Yang, Hee-Chul;Kim, In-Tae;Lee, Han-Soo;Cho, Yung-Zun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.303-309
    • /
    • 2010
  • For the pyrochemical process of spent nuclear fuels, recovery of LiCl-KCl eutectic salts is needed to reduce radioactive waste volume and to recycle resource materials. This paper is about recovery of residual LiCl-KCl eutectic salts in radioactive rare earth precipitates (rare earth oxychlorides or oxides) by using a vacuum distillation process. In the vacuum distillation test apparatus, the salts in the rare earth precipitates were vaporized and were separated effectively. The separated salts were deposited in three positions of the vacuum distillation test apparatus or were collected in the filter and it is difficult to recover them. To resolve the problem, a vacuum distillation and condensation system, which is subjected to the force of a temperature gradient at a reduced pressure, was developed. In a preliminary test of the vacuum distillation/condensation recovery system, it was confirmed that it was possible to condense the vaporized salts only in the salt collector and to recover the condensed salts from the salt collector easily.

Simulation on Recovery of Methane Greenhouse Gas from Biogas Using 3 Stage Membrane Modules (바이오가스로부터 온실가스 메탄 회수를 위한 3단 분리막 공정 모사)

  • Lee, Yongtaek
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.243-251
    • /
    • 2018
  • Methane is one of the important greenhouse gases and methane is the major component of the biogas. A multiple stage membrane process was developed and analysed with the numerical analysis so that the mole fraction of methane in the final product could be kept higher than 0.95 and simultaneously the recovery of methane was also maintained higher than 99% from the biogas using 3 polysulfone hollow fiber membrane modules which were properly connected. As the feed pressure of the biogas, the mole fraction of methane in the biogas and the membrane area in the membrane module are increased, the methane mole fraction of the final product are found to be increased. However, a proper membrane area in the module should be carefully selected in order to achieve the satisfactory goal of 0.95 mole fraction of methane and 99% recovery of methane from the biogas. Even if the multiple membrane process is utilized with the properly selected membrane modules, the limited operating ranges have to be applied in the following parameters : the feed pressure, the flow rate, the mole fraction of methane in the biogas to get both the target methane concentration and the recovery rate of methane.

Development of a Plum (Japanese Apricot) Seed Remover for Multipurpose Plum Flesh Processing

  • Ali, Mohammod;Park, Seong-Jin;Akhter, Tangina;Kim, Gwang-Shim;Yang, KyuWon;Seonwoo, Hoon;Kim, Hyuck-Joo
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.283-292
    • /
    • 2017
  • Purpose: Japanese Apricot, a type of plum, has various medicinal and economical applications. Plums are quite popular worldwide, but their deseeding remains a serious impediment to their processing. Therefore, a plum (Japanese Apricot) seed remover (PSR) was developed that can use various types of cutters according to the purpose of the plum processing, and its performance was evaluated. Methods: The proposed PSR, which allows multipurpose cutters, namely, zero-, two-, and four-blade cutters, to be installed, was first designed and manufactured. To identify appropriate parameters related to the cutting pressure, plums were harvested from three regions during three harvesting periods, and their geometrical and mechanical properties were measured. After application of the parameters related to the cutting pressure, a performance test was carried out on both fresh and frozen plums by identifying the ratios of the flesh recovery, seed recovery, seed breakage, deseeding efficiency, and machine efficiency. Results: The results show that, using the proper calculation of the processing parameters, 100% deseeding efficiency was facilitated regardless of the type of cutter used. However, in the case of a four-blade cutter, there are significant differences in the flesh recovery ratio according to the plum setting angle. Between the fresh and frozen plums, all cutters showed a significantly better flesh recovery ratio for the case of fresh plums. Conclusions: This machine will advance the plum processing technology, and eventually help the plum industry flourish.

The Relationship between the Plantar Center of Pressure Displacement and Dynamic Balance Measures in Hemiplegic Gait (편마비 보행 시 족저압력중심의 이동특성과 동적균형능력의 상관관계 연구)

  • Park, Ji-Won;Nam, Ki-Seok;Back, Mi-Youn
    • Physical Therapy Korea
    • /
    • v.12 no.1
    • /
    • pp.11-21
    • /
    • 2005
  • The purpose of this study was to investigate how COP displacement of a hemiplegic foot in stance phase during gait is related to clinical balance measures and the recovery stage in hemiplegic stroke patients. Twenty-eight functionally ambulant hemiplegic patients who had suffered from strokes and thirty age-matched healthy subjects participated in this study. COP parameters were calculated. Clinical balance was measured using the Functional Reach Test (FRT) and Timed Up and Go Test (TUGT). The recovery stage, proprioception, and clonus of the ankles or lower extremities were also measured for physical impairment status. The COPx max-displacement in the medial-lateral side of the stroke patients was significantly longer than that of the normal group (p=.038). The COPy max-displacement in the anterior-posterior side of the stroke patients was significantly shorter than that of normal group (p<.001). Significant differences in the COPx and COPy displacement asymmetry index were found between the two groups (p<.01). The FRT was correlated with the COPx displacement (r=.552) and COPy displacement (r=.765). The TUGT was correlated with the COPy displacement (r=-.588) only. The recovery stage of the lower extremities was correlated with COPy displacement (r=.438). The results of the study indicate that the characteristic of COP displacement in hemiplegic feet in stance phase during gait is related to balance ability and recovery in stroke patients. COP parameters acquired by the mapping of foot pressure in stance phase during gait will provide additional useful clinical information. This information can be used by clinicians to assess objectively the pathologic gait with other diseases and to evaluate the therapeutic effects on gait in stroke patients.

  • PDF

Enhancement of the Performance a Centrifugal Compressor in an Automobile Turbocharger by Modifying the Circumferential Inlet Height of Volute (원주방향 볼류트 입구 높이를 수정한 자동차용 터보차저 원심압축기의 성능 향상)

  • Zhou, Tianjun;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • To enhance the performance of an automobile turbocharger compressor, the circumferential inlet heights of the volute were modified and the flow field for the combined region of the diffuser and volute was numerically investigated using commercial software. Basically, a well-designed volute should have a high pressure recovery coefficient and a low loss coefficient for the total pressure. In this study, two circular volutes with the same cross sectional shape and tongue angle, but circumferentially different volute inlet heights, were selected. One volute had the middle inlet in the cross-section at the circumferential angle of $90^{\circ}$ but gradually lower inlet heights for the angles between $90^{\circ}$ to $360^{\circ}$ with respect to the cross sectional center of the volute, while maintaining the same height between the tangential line connecting the lowest positions of the cross section and the line connecting the volute inlets in the circumferential direction (case 1 volute). The other volute has an inlet height that is 2 mm lower than in case 1 volute such that the tongue section has a tangential inlet (case 2 volute). The results showed that the case 2 volute had a higher total pressure ratio because of its higher pressure recovery coefficient and higher isentropic efficiency, resulting from the lower loss coefficient along the circumferential position than the case 1 volute.

Application of RO Membrane Process for Reuse of MBR Effluent (MBR 유출수 재활용을 위한 RO 막분리 공정에 대한 연구)

  • Yoon, Hyun-Soo;Kim, Jong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1391-1398
    • /
    • 2010
  • Reuse feasibility of MBR effluent of S Electronic Company's organic wastewater as a LCD process water was investigated by a $32m^3/d$ pilot-scale RO membrane process. The effects of operating pressure and permeate flux at constant 85% recovery of RO membrane process using MBR effluent were analyzed for transmembrane pressure and period for CIP by membrane fouling as well as rejection of TOC and conductivity. MBR effluent requires additional treatment to meet the LCD process water quality criteria of TOC<1 mg/L and conductivity<$100{\mu}S/cm$ which is stringent as compared with those of conventional reuse water quality criteria. The RO process operated at 85% recovery with stepwise increasing of permeate fluxes from 12.5 LMH to 22.0 LMH was able to meet LCD process water quality criteria. However, the transmembrane pressure increased and the period of CIP decreased as increasing permeability fluxes due to fouling of RO membrane. The optimum operational conditions of RO membrane process were permeate fluxes of 16.5~18.5 LMH with operating pressure of $6.7{\sim}12.4kgf/cm^2$ and CIP period of 20~25 days at constant 85% recovery.

Numerical Analysis of the Whole Field Flow in a Centrifugal Fan for Performance Enhancement - The Effect of Boundary Layer Fences of Different Configurations

  • Karanth, K. Vasudeva;Sharma, N. Yagnesh
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.110-120
    • /
    • 2009
  • Generally the fluid flows within the centrifugal impeller passage as a decelerating flow with an adverse pressure gradient along the stream wise path. This flow tends to be in a state of instability with flow separation zones on the suction surface and on the front shroud. Hence several experimental attempts were earlier made to assess the efficacy of using boundary layer fences to trip the flow in the regions of separation and to make the flow align itself into stream wise direction so that the losses could be minimized and overall efficiency of the diffusion process in the fan could be increased. With the development of CFD, an extensive numerical whole field analysis of the effect of boundary layer fences in discrete regions of suspected separation points is possible. But it is found from the literature that there have been no significant attempts to use this tool to explore numerically the utility of the fences on the flow field. This paper attempts to explore the effect of boundary layer fences corresponding to various geometrical configurations on the impeller as well as on the diffuser. It is shown from the analysis that the fences located on the impellers near the trailing edge on pressure side and suction side improves the static pressure recovery across the fan. Fences provided at the radial mid-span on the pressure side of the diffuser vane and near the leading edge and trailing edge of the suction side of diffuser vanes also improve the static pressure recovery across the fan.