• Title/Summary/Keyword: Pressure Monitoring

Search Result 1,095, Processing Time 0.028 seconds

Optimum electrode selection for measuring the abdominal pressure using bio-impedance method (비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정)

  • An, Yang-Su;Kim, Keo-Sik;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

The Monitoring on Gradual Change of Seepage Blocking State with the Hydraulic Head Loss Rate Change According to Passage of time in Sea Dike Embankment (수두손실률의 경시변화에 의한 방조제 제체의 점진적인 차수상태 변화 감시)

  • Eam, Sung Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • In this study it was adopted on sea dike monitoring that the safety monitoring with statistical limits which was adapted usually on safety monitoring by measuring pressures, stresses or deformations. And also the hydraulic head loss rate change according to passage of time was calculated for the purpose of safety monitoring. Safety monitoring by setting the statistical limit on the measured pore water pressure graphs need to be supplemented with an additional method of monitoring because the difference between the rise and fall of the tide was irregular. Safety monitoring by the limits set from values predicted by linear regression and standard errors on the hydraulic head loss graph was not affected by irregularity of tide. But if the condition of an embankment is changed gradually and slowly, it will not be detected on the hydraulic head loss graph. The graph of hydraulic head loss rate for every 24 hours vs date showed clearly that the sea water blocking state was getting better or not even though it was changed gradually and slowly.

A Design and Implementation of Industrial Fluid Monitoring System (산업공정상의 유체 유동 모니터링 시스템 설계 및 구현)

  • Lee, Won-Joo;Lee, Sang-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.99-106
    • /
    • 2010
  • In this paper, we propose an industrial fluid monitoring system which performs the flow control function and monitors fluid pressure transmitted from MFC(Mass Flow Controller) unit. This system consists of MFC unit, channel device, and monitoring management software. MFC unit transmits the measured data of the fluid pressure to the channel device which would provide the input/output interface between management software, monitoring and MFC unit. The monitoring and management software control and analyze by monitoring real time measurements of fluid pressure from each channel of MFC unit. This software can process 20 channels and 0.1 monitoring cycle which gives 200 data measurement per second (i.e., 720,000 data/hour). At this time, the storage space increases in proportion to the rise of input data. This growth of data and storage space makes loss of data access efficiency. Therefore, it demands the implementation by sensing scheme of change scope and data, which can effectively manage the data.

Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure (무구속적 맥파 전달 시간의 측정을 통한 혈압 추정)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

Generalized Sidelobe Canceler for TPMS Interference Cancellation (TPMS 간섭제거를 위한 Generalized Sidelobe Canceler)

  • Park, Cheol;Hwang, Suk-Seung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.5
    • /
    • pp.663-668
    • /
    • 2012
  • A TPMS(Tire Pressure Monitoring System) is a wireless communication system designed to monitor the pressure and temperature of pneumatic tires of a vehicle. In order to provide the aid in protecting a driver, this system reports tire pressure information to the driver of the vehicle. Since the wireless communication technique should be employed to transmit the TPMS data from each tire to signal processing unit in the vehicle, it suffers from interference signals from external electrical or electronics equipments. In this paper, we propose the TPMS interference cancellation technique based on GSC(Generalized Sidelobe Canceler), which does not have only the excellent performance like MVDR(Minimum-Variance-Distortionless-Response) but also has the low computational complexity comparing with MVDR. The performance of interference suppression is conformed by computer simulation examples.

Monitoring and Control of Turing Chatter using Sound Pressure and Stability Control Methodology (음압신호와 안정도제어법을 이용한 선삭작업에서의 채터 감시 및 제어)

  • 이성일
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.4
    • /
    • pp.101-107
    • /
    • 1997
  • In order to detect and suppress chatter in turning process, a stability control methodology was studied through manipulation of spindle speeds regarding to chatter frequencies, The chatter frequency was identified by monitoring and signal processing of sound pressure during turing on a lathe. The stability control methodology can select stable spindle speeds without knowing a prior knowledge of machine compliances and cutting dynamics. Reliability of the developed stability control methodology was verified through turing experiments on an engine lathe. Experimental results show that a microphone is an excellent sensor for chatter detection and control .

  • PDF

Self-sensing measurement of piezo inkjet and its Applications (피에조 잉크젯의 셀프 센싱 검출 및 응용)

  • Kwon, Kye-Si;Kim, Wou-Sik;Kim, Sang-Il;Shin, Seung-Joo;Kim, Seong-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.366-372
    • /
    • 2007
  • Self-sensing measurement of piezo inkjet and its application are discussed. The pressure wave inside the inkjet dispenser was measured by current measurement due to self-sensing capability of PZT. The pressure wave measured from current was verified by commercially available laser vibrometer. Here, two applications using self-sensing signal were discussed: waveform design for high speed jetting and condition monitoring. For waveform design, two pulse waveform was designed based on self-sensing signal such that the pressure wave after droplet formation can be minimized. For condition monitoring, self-sensing signal was shown to be effective in detecting air bubble trapped in inkjet printhead.

  • PDF

Design of ambulatory urodynamics monitoring system (휴대용 하부요로기능 검사 장치의 설계)

  • Lee, S.O.;Kim, K.S.;Yoon, D.Y.;Seo, J.H.;Song, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.48-50
    • /
    • 2005
  • Urodynamics describes a collection of tests designed to evaluate lower urinary tract function and can be performed using retrograde filling of the bladder within a room. In this study, we designed and calibrated the potable urodynamics monitoring system using DSP chip (TMS320VC33, Texas Instrument$^{TM}$, U.S.) and collected pressure and EMG using calibration kit (DPT9022K0122, Medtronics$^{TM}$, U.S.). This system can make patients more comportable and monitor spontaneous urination during daily life.

  • PDF

Durable and Sustainable Strap Type Electromagnetic Harvester for Tire Pressure Monitoring System

  • Lee, Soobum;Kim, Dong-Hun
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.473-480
    • /
    • 2013
  • A new concept design of electromagnetic energy harvester is proposed for powering a tire pressure monitoring sensor (TPMS). The thin coil strap is attached on the circumferential surface of a rim and a permanent magnet is placed on the brake caliper system. When the wheel rotates, the relative motion between the magnet and the coil generates electrical energy by electromagnetic induction. The generated energy is stored in a storage unit (rechargeable battery, capacitor) and used for TPMS operation and wireless signal transmission. Innovative layered design of the strap is provided for maximizing energy generation. Finite Element Method (FEM) and experiment results on the proposed design are compared to validate the proposed design; further, the method for design improvement is discussed. The proposed design is excellent in terms of durability and sustainability because it utilizes the everlasting rotary motion throughout the vehicle life and does not require material deformation.

A Development of Blood Pressure and Blood Sugar Monitor Using the Bluetooth and Tele-monitoring System (블루투스를 이용한 혈압, 혈당 측정 단말기 제작 및 원격건강관리시스템 개발)

  • Hong, Seung-Beom;Kim, Sung-Jin;Lee, Won-Keun;Lee, Moo-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.80-83
    • /
    • 2008
  • We propose the tele-monitoring system to real-time medical signal system and implemented the blood-pressure and blood-sugar monitoring system with bluetooth communication system. And, it transmits patient's data blood pressure, blood sugar to doctor and doctor sends the result of medical treatment to patient's phone, hand-phone or PDA. We developed the measurer as portable type in order to non-restrained monitor.

  • PDF