• Title/Summary/Keyword: Pressure Measuring System

Search Result 484, Processing Time 0.027 seconds

Atomization Characteristics of Fuel Spray in Fuel Injector in Gasoline Direct-Injection Engine (가솔린 직분식 엔진 인젝터의 연료 분무 미립화 특성)

  • Lee, C.S.;Lee, K.H.;Choi, S.C.;Kwon, S.I.
    • Journal of ILASS-Korea
    • /
    • v.4 no.2
    • /
    • pp.33-39
    • /
    • 1999
  • This paper presents the spray atomization characteristics of the high-pressure gasoline injector for the direct-injection gasoline engine. The gasoline sprays of the injector were minted into a pressurized spray chamber with a optical access at various ambient pressures. The atomization characteristics of fuel spray such as mean diameter, mean velocity of droplet were measured by the phase Doppler particle analyzer system. In order to investigate the effect of fuel injection pressure on the quantitative characteristics of spray, the global visualization and experiment of particle measurement in the fuel spray were investigated at 3, 5 and 7 MPa of injection pressure under different ambient pressure in the spray chamber. Based on the results of this work, the fuel injection pressure of fuel injector in gasoline direct-injection engine have influence upon distribution of the mean velocity and droplet size of fuel spray. Also, the influence of injection pressure on the velocity distribution at various measuring location were investigated.

  • PDF

The minimum fluidized velocity in fluidizing combustion bed of uniform particle size distribution system. (균일입자계 유동층연소로의 최소유동화 속도에 관한 연구)

  • 조병렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 1996
  • The pressure fluctuations in a gas-solid fluidized bed has been analysed using s statistical method interpreting fluidized 냥d behavior. The performing statistical a analysis of the pressure fluctuations in a fluidized bed of 6.7cm-ID. using uniform p particle size of 115 to $1015{\mu}m$ in diameter. The fluidized gas used air(velocity 0.1~1.2m/sec) at settled bed height to diameter ratios which is LlD=l.O. Then, the pressure fluctuations measured by DPT(differantial pressure transducer). The measuring characteristic values of pressure fluctuation were the mean value and standard value, and also, it has been found that the standard deviation of the pressure fluctuations can be effectively used to predict minimum fluidizing velocity and to explain the fluidized phenomena.

  • PDF

Pressure Control of SR Driven Hydraulic Oil-Pump Using Data based PID Controller

  • Lee, Dong-Hee;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.800-808
    • /
    • 2009
  • This paper presents a practical method of pressure control for a hydraulic oil-pump system using an SR (Switched Reluctance) drive. For a 6Mpa grade hydraulic oil-pump, a 2.6kW SR drive is developed. In order to get high performance pressure dynamics in actual applications, a data based PID control scheme is proposed. The look-up table from a pre-measured data base produces an approximate current reference based on motor speed and oil-pressure. A PID controller can compensate for the pressure error. With the combination of the two references, the proposed control scheme can achieve fast dynamics and stable operation. Furthermore, a suitable current controller considering the nonlinear characteristics of an SRM (Switched Reluctance Motor) and practical test methods for data measuring are presented. The proposed control scheme is verified by experimental tests.

Electrodermal Activity at the Left Palm and Finger in Accordance with the Pressure Stimuli Applied to the Left Scapula

  • Kim, Jae Hyung;Kim, Su Sung;Son, Jung Man;Kim, Yung Jae;Baik, Sung Wan;Jeon, Gye Rok
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.235-242
    • /
    • 2016
  • A system for measuring the electrodermal activity (EDA) signal occurring at the sweat glands in the left palm and left finger of the human body was implemented in this study. The EDA measurement system (EDAMS) consisted of an algometer, a biopotential measurement system (BPMS), and a PC. Two experiments were performed to evaluate the function and clinical applicability of EDAMS. First, an experiment was carried out on the linearity of the voltage and the pressure that comprised the output signals of the algometer used for applying a pressure stimulus. Second, the amplitude of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the amplitude of the EDA signal increased. The amplitude of the EDA signal at the left palm was observed to be greater than that at the left finger. The amplitude of the EDA signal was observed to increase in a relatively linear relation with the intensity of the pressure stimuli. In addition, the latency of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the latency of the EDA signal decreased. The latency of the EDA signal at the palm was observed to be less than that at the finger. The latency of the EDA signal was observed to decrease nonlinearly with the pressure stimuli.

Effects of Knit Fabric Layering and Flat Seam Direction on Stretchability and Clothing Pressure

  • Lee, Hyojeong;Eom, Ran-i;Park, Sunhee;Lee, Yejin
    • Journal of Korean Living Environment System
    • /
    • v.24 no.4
    • /
    • pp.533-540
    • /
    • 2017
  • This study analyzes the stretchability and clothing pressure of fabrics made from stretchy knit materials, and uses the baseline data to develop various functional clothing made from stretchy knit fabrics. To observe the changes in the stretchability and clothing pressure, we observed the compatibility of the two materials (tricot and power-net), presence of flat seam, fabric layering, and flat seam direction as key variables. A standard test method for stretch properties (ASTM D2594) was used for measuring the stretchability of the material. Clothing pressure measurements were analyzed in terms of the mean and standard deviation values, and the correlation of the stretchability. In the case of tricot, the presence of flat seam increased the stretchability of the fabric regardless of the fabric layering. However, when tricot and the less stretchable power-net were combined, the presence of flat seam did not increase the stretchability. Flat seam did not interfere with or limit the stretchability of the fabric, but they did increase the clothing pressure at the seam. The stretchability had a negative correlation with the clothing pressure except along the flat seam.

The Static Pressure Distribution and Flow Characteristics Inside the High-Pressure Swirl Spray (고압 스월분무 내부의 압력분포 및 유동특성에 대한 연구)

  • Moon, Seok-Su;Abo-Serie, Essam;Choi, Jae-Joon;Bae, Choong-Sik
    • Journal of ILASS-Korea
    • /
    • v.11 no.3
    • /
    • pp.168-175
    • /
    • 2006
  • The static pressure distribution and flow characteristics inside the high-pressure swirl spray were investigated by measuring the static pressure inside the spray and applying the computational fluid dynamics (CFD). The static pressure difference between inner and outer part of spray was measured at different axial locations and operating conditions using a piezo-resislive pressure transducer. To obtain the qualitative value of swirl motion at different operating conditions, the spray impact-pressure at the nozzle exit was measured using a piezo-electric pressure transducer, and the flow angle was measured using a microscopic imaging system. The flow characteristics inside the high pressure swirl spray was simulated by the 1-phase 3-dimensional CFD model. The effect of pressure alternations on spray development was discussed with macroscopic spray images and a mathematical liquid film model. The results showed that the static pressure drop is observed inside the swirl spray as a result of the dragged air motion and the centrifugal force of the air. The recirculation vortex inside the spray was also observed inside the swirl spray as a result of the adverse pressure gradient along the axial locations. The results of analytical liquid film model and macroscopic spray images showed that the static pressure structure is one of the main parameters affecting the swirl spray development.

  • PDF

Studies on Drilling and Cutting Characteristics for Granite Rocks Using Waterjets (워터젯을 이용한 화강암 천공과 절삭 특성에 관한 연구)

  • Oh, Tae-Min;Hong, Eun-Soo;Cho, Gye-Chun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1338-1345
    • /
    • 2009
  • Although rock excavation is necessary for the effective utilization of urban space, most conventional rock excavation methods, including the blasting method, cause high noise and vibration. Meanwhile, if a high pressure waterjet system is applied to excavate underground spaces in urban areas, the public grievance can be reduced by low noise and vibration. In this study, an abrasive waterjet system is designed and developed to study the influence of various performance parameters such as jet pressure, nozzle traverse speed, stand-off distance, or abrasive feed rate on waterjet excavation performance in laboratory. Using the developed waterjet system, rock drilling characteristics are identified by measuring drilling depths as a function of the jet exposure time. The drilling depth linearly increases with increasing the jet exposure time(under 60sec). Rock cutting characteristics are also obtained with various jet pressures(1600~3200kg/$cm^2$) and nozzle traverse speeds(1.9~14.1mm/s): The cutting depth is nonlinearly related to the jet pressure and traverse speed. Indeed, the cutting depth increases with an increase in the jet pressure and a decrease in the nozzle traverse speed. This trend can be explained by energy transferring/loss mechanism.

  • PDF

A Development Of The Portable Spirometry System Of Pressure Method Using Static Pressure In Pitot Tube (개구관에서의 정체압을 이용한 차동 압력 방식의 휴대형 호흡측정 시스템 개발)

  • 이종수;신창민;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.479-486
    • /
    • 2001
  • Spirometer is a medical equipment which diagnoses respiratory function by measuring 9as volume across Patient's lunes through airway. Because a little overdose of anesthesia medicine can take away Patient's life in the ventilator for a surgical operation. an exact measurement of respiring volume is very important. This Paper Presented an exact flow volume calculation method from factors having an influence on measurement and introduced a spirometry system for an anesthesia ventilato. This system, using differential Pressure sensor measured flow by mutual relation with Pressure. temperature. gas density and linearization from the 2nd order characteristics of differential pressure with flow.

  • PDF

Development of Hovering AUV Test-bed for Underwater Explorations and Operations

  • Byun, Seung-Woo;Choi, Hyeung-Sik;Kim, Joon-Young
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.4
    • /
    • pp.218-224
    • /
    • 2013
  • This paper describes the design and control of a hovering AUV test-bed and analyzes the dynamic performance of the vehicle using simulation programs. The main purpose of this vehicle is to carry out fundamental tests of its station keeping, attitude control, and desired position tracking. Its configuration is similar to the general appearance of an ROV for underwater operations, and its dimensions are $0.75m{\times}0.5m{\times}0.5m$. It has four 450-W thrusters for longitudinal/lateral/vertical propulsion and is equipped with a pressure sensor for measuring the water depth and a magnetic compass for measuring its heading angle. The navigation of the vehicle is controlled by an onboard Pentium III-class computer, which runs with the help of the Windows XP operating system. This provides an appropriate environment for developing the various algorithms needed for developing and advancing a hovering AUV.

A Design of Telemetry Ground System for the Scientific Sounding Rocket KSR-420S (과학관측로케트 KSR-420S의 원격측정 지상시스템 설계)

  • 이수진;이재득;조광래;유장수
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.26-32
    • /
    • 1991
  • Korea Aerospace Research Institute(KARI) performs research on developing the scientific sounding rocket(KSR-420S) for measuring ozone profile and atmosphere layer over korean peninsula. Informations about performances of flighting scientific rocket, that is temperature, strain, acceleration, pressure, rocket attitude and ranging data, and measuring data of ozone, ionosphere and X-ray are transmitted ground system by rocket onboard transmitting system. In this paper, the telemetry ground system which is compatible with the KSR-420S is designed for tracking the trajectory and receiving the incoming signals.

  • PDF