• 제목/요약/키워드: Pressure Leak Test

검색결과 96건 처리시간 0.02초

일부 PVC 수지 제조 및 가공 근로자의 염화비닐 폭로 평가와 대책에 관한 조사 연구 (A Study on the Control and Exposure Assessment to Vinyl Chloride in the Factory Processing and Producing PVC Resin)

  • 박동욱;신용철;이나루;이광용;오세민;정호근
    • 한국산업보건학회지
    • /
    • 제4권1호
    • /
    • pp.33-42
    • /
    • 1994
  • This study was carried out to assess worker exposure to vinyl chloride monomer (VCM) and to present control measures in the factories processing and producing polyvinyl chloride (PVC) resin. The conclusion remarks are as follows. Only two personal samples in the factory ("E") processing polyvinyl chloride resin were analysed to be 27.6 ppm and 12.6 ppm, respectively. But, these concentration exceed 1 ppm, Permissible Exposure Limits (PEL) of OSHA. So, worker's exposure to VCM at "E" factory should be reevaluated. In "A", "B" and "C" factory producing polyvinyl chloride resin, the average worker's exposures to VCM were 0.12 ppm, 0.86 ppm and 1.23 ppm, respectivery. Worker exposure to VCM at distillation and dry process was higer than other processes at "A" factory. The average exposure concentration of worker at polymerization process of "B" and "C" factory was 1.23 ppm, and 1.46 ppm respcetively. These concentration exceed 1 ppm, Permissible Exposure Limits of OSHA. Control room of "B" and "C" factory had 0.91 ppm and 0.65 ppm of worker's exposure concentration respectively. "A" factory was evaluated to be "acceptable", but "B" and "C" factories were evaluated to be "not acceptable", by the workplace exposure assessment program of AIHA. Process other than bagging and control room of "A" factory was evaluated to "not acceptable". Immediate correction measures for preventing workers from exposure to VCM should be performed in the factories or process that were evaluated to be "not acceptable". After these control measures are taken, worker exposure to VCM must be reevaluated through personal air monitoring. Control measures presented by this study are complete sealing of connecting pipe lines, flanging, packing, bolting and nutting. Periodic leak test for leak parts is also required. And positive pressure facility should be constructed at control room of "B" and "C" factory. Fresh air through cleaner such as HEPA filter should be supplied to control room. In addition to these control measures, periodic personal monitoring for evaluating worker exposure to VCM should be performed.

  • PDF

Forced Potential Scheme 미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징 (Low Temperature Hermetic Packaging by Localized Heating using Forced Potential Scheme Micro Heater)

  • 심영대;신규호;좌성훈;김용준
    • 마이크로전자및패키징학회지
    • /
    • 제10권2호
    • /
    • pp.1-5
    • /
    • 2003
  • 기존 형상의 미세 가열기를 이용한 마이크로 시스템 패키징의 문제점을 해결하기 위해 새로운 형상의 미세 가열기를 제작하여 패키징 실험을 시행하였다. 기존 형상의 미세 가열기와 새로운 미세 가열기의 형상을 각각 제작하여 접합시에 미세 가열기에 발생하는 열분포를 IR카메라를 이용하여 실험하였다. 기존 형상의 미세 가열기가 불균일하게 가열되는 반면, 새로운 형상의 미세 가열기는 매우 균일하게 가열되는 형상을 나타내었고, IR 카메라를 이용한 실험 결과를 바탕으로 각기 다른 형상의 미세 가열기를 이용하여 접합 실험을 실시하였다. 접합 실험시 사용한 미세 가열기는 폭 $50{\mu}m$, 두께 $2{\mu}m$로 제작하였으며, 0.2Mpa 의 압력을 Pyrex glass cap에 가한 상태에서 150mA의 전류를 공급하여 접합을 완료하였다. 접합이 완료된 시편들에 대해서 IPA를 통한 leakage check실험을 실시하였으며, 기존 형상의 미세 가열기를 이용한 시편들은 66%가 테스트를 통과한 반면 새로운 형상의 미세 가열기를 이용한 시편들은 85%이상이 테스트를 통과하였다. Leakage 실험을 통과한 각각의 시편들에 대해서 접합력 측정을 실시한 결과, 기존 형상의 미세 가열기를 이용한 시편들은 15∼21Mpa의 접합력을 나타내었고, 새로운 형상의 미세 가열기를 이용한 시편들은 25∼30Mpa의 우수한 접합력을 나타내었다.

  • PDF

대동맥 열공부에 발생한 비전형적 대동맥 협착증: 외과적 수술을 가한 1례 (Atypical Aortic Coarctation at the Level of Aortic Hiatus: Report of a case treated by bypass graft)

  • 남민우;유회성;지정희
    • Journal of Chest Surgery
    • /
    • 제5권1호
    • /
    • pp.13-18
    • /
    • 1972
  • In 1835,Schlesinger first described a case of subisthmlc lower thoracic aortic coarctation. Since Olim`s unsuccessful reconstructive surgery in 1949 and Beattie`s first successful resection with homograft replacement on such a lesion in 1951 were reported,about 20 cases of atypical aortic coarctation had been treated by definitive surgery until 1964. In Korea, only 2 cases of atypical aortic coarctation treated by bypass graft were reported until now. This is the third case-report treated by reconstructive surgery. The patient,11 year old girl who had 2 year history of headache, visual weakness, intermittent claudlcation, and general weakness, was first diagnosed of having the hypertension due to atypical coarctation by the findings of high blood pressure[170/110mmHg] at the upper extremity and weak pulsation on both femoral artery,murmur on the epigastrium, absence of aortic knob, and aorto graphy. Aortography demonstrated the isolated segmental narrowing[length 5cm, diameter 0.4cm] at the level of aortic hiatus 2cm above celiac arterial origin, the dilated right 9th, 10th, 11th intercostal arteries with multiple dimunitive collaterals and no associated abnormalities in the other arteries. Preoperatlve positive findings were strong positive mantoux test, high AST[720 units]. transient mild cardiomegaly with right lung infiltration on chest X-ray and suggestive left ventricular hypertrophy on ECG. On December 1970, through separate left thoracotomy and abdominal approach, bypass graft between descending thoracic aorta and abdominal aorta below renal artery was performed. The operation was first successful with satisfactory reduction of hypertension on the upper trunk[postoperatlve 130/80mmHg] and strong pulsation on the lower extremities[postop. O, postop. 140/100mmHg]. However,6 weeks after surgery, she expired of sudden hemoptysis and shock due to anastomotic leak within the thorax. Operative finding disclosed that the affected aorta was firm, with rich periaortic fibrosis and the outer diameter of stenotic site was not attenuated. Histopathology of the resected specimen was also compatible with primary arteritis.

  • PDF

비전통 유·가스정에서 ESP 성능 평가를 위한 Flow Loop 시스템 개발 (Development of Flow Loop System to Evaluate the Performance of ESP in Unconventional Oil and Gas Wells)

  • 이승재;최준호;이정환
    • 한국가스학회지
    • /
    • 제27권2호
    • /
    • pp.7-15
    • /
    • 2023
  • 전기식 액중형 펌프 (electrical submersible pump, ESP)는 인공채유 (artificial lift) 기법 중 적용성과 운영 효율이 높아 전 세계 생산정에서 운영되고 있다. 저류층에서 ESP 운영 시 온도·압력, 가스·오일비, 유량 등의 변수는 ESP 성능에 영향을 미치는 요소로서, 특히 생산유체 내 자유 가스 (free gas)는 ESP의 수명 및 운영 효율을 감소시키는 주요 요인에 해당한다. 이에 본 연구에서는 ESP 성능에 영향을 미치는 변수를 정량적으로 분석하고자 현장 운영조건에서 ESP 성능실험과 손상모사 실험이 가능한 환형 유동 시스템 (flow loop system) 을 개발하였다. 개발 장치는 ESP와 튜빙 (tubing)을 하나의 시스템으로 연동시켜 ESP의 고장 및 원인 진단, 튜빙의 누출 특성을 파악할 수 있는 일체형 시스템에 해당한다. 본 연구에서는 ESP 성능 평가와 관련된 단상 유체 (single phase)와 2상 유체 (two phase) 실험을 통해 ESP를 안정적으로 운영하기 위한 유동 조건을 규명하였다. 도출된 결과값은 ESP 고장 예측 및 진단 프로그램 개발을 위한 기본 자료를 제공하며, ESP 운영을 위한 최적 운영 조건 및 고장 진단을 위한 실시간 모니터링에 활용할 수 있을 것으로 판단된다.

소아 개심술에 있어서 변형 초여과법(Modified Ultrafiltration)이 술후 상태에 미치는 영향 (Effect of Modified Ultrafiltration on the Postoperative State after Pediatric Open Heart Surgery.)

  • 방종경;천종록;김규태
    • Journal of Chest Surgery
    • /
    • 제31권5호
    • /
    • pp.456-465
    • /
    • 1998
  • 개심술후에 영아나 작은 소아에서는 수분의 체내 저류현상이 더욱 심하게 나타난다. 이에 대한 치료법의 하나로 개심술시 변형 초여과법을 적용함으로써 술후 상태에 미치는 영향을 알아 보고자 하였다. 개심술을 받았던 5세이하의 소아를 대상으로 개심술후 변형 초여과법을 적용하였던 환아(초여과군) 10명과 초여과법을 실시하지 않았던 대조군 10명의 2군으로 나누어서 개심술에 따른 조기 성적을 비교 분석하였다. 환아의 연령, 체중, 심폐기 충진액의 총량과 이에 첨가한 혈액의 양, 그리고 체외순환시간과 대동맥차단시간 등의 값들은 모두 양군간에 유의한 차이가 없었다. 변형 초여과법을 적용함에 있어서 관류속도는 평균 171.4ml/min, 관류시간은 평균 18.9분이 소요되었고, 이 동안에 걸러진 수액의 총량은 평균 38.4ml/kg, 심폐기의 혈액을 환자에게 재수혈한 양은 평균 32.1ml/kg였다. 술후 24시간동안의 출혈량은 초여과군에서 평균 14.5ml/kg/24hr, 대조군에서 13.7ml/kg/24hr였고, 같은 기간에 수혈한 양은 초여과군에서 전혈 6.6ml/kg/24hr, 혈장 65.7ml/kg/24hr, 대조군에서는 전혈 15.2ml/kg/24hr, 혈장 59.6ml/kg/24hr이었다. 이는 임상적으로는 초여과군에서 전혈의 수혈량이 대조군에 비하여 훨씬 적어 보였지만 통계학적으로 유의한 차이는 없었다. 술전후 적혈구용적률의 변화는, 초여과군에서는 체외순환 시작후 10분에 평균값이 26.5%로 떨어졌다가 초여과법 종료 5분후에는 37.1%로 급격히 상승하였고, 대조군에서는 체외순환중의 24.7%에서 체외순환이 끝나고 20분이 경과한 후에도 30.5% 수준으로밖에 상승하지 못하였다. 그러므로 적혈구용적률의 변화를 체외순환중의 수치에 대한 상승률(%)로 나타냈을 때, 초여과군은 40%, 대조군은 23%로써 양군간에 통계학적으로 유의한 차이를 보였다(p=0.002). 초여과법 시행에 따른 수축기 및 이완기동맥압의 변화에 있어서는 양군간에 유의한 차이가 없었으며, 평균동맥압의 변화는 양군간에 통계학적으로 유의한 차이는 없었으나(p=0.086), 임상적으로는 상당한 차이를 보였다. 결론적으로, 소아환자에서 개심술후에 변형 초여과법을 적용했을 때, 거의 일률적으로 적혈구용적률과 동맥혈압이 상승함을 볼 수 있었고, 이는 환아를 중환자실로 옮긴 후에도 지속됨으로써 개심술직후 환아관리에 긍정적인 효과를 발휘하는 것으로 평가된다. 따라서 향후 영아나 작은 소아의 개심술에 있어서 변형 초여과법은 보다 많은 빈도로 이용될 것으로 전망된다.

  • PDF

지상식 LPG 저장탱크의 외부화재에 의한 BLEVE 가능성 해석 (A Study on the Probability of BLEVE of Above-ground LP Gas Storage Tanks Exposed to External Fire)

  • 이승림;이영순
    • 한국가스학회지
    • /
    • 제7권1호
    • /
    • pp.19-23
    • /
    • 2003
  • 최근 국내에서도 정량적 위험성 평가 기법을 위험시설물에 도입하여 위험도를 관리하면서 LPG 저장탱크에 대한 사고후 피해영향평가에 대한 연구는 다각적으로 이루어지고 있으나 BLEVE(Boiling Liquid Expanding Vapor Explosion, BLEVE)의 조건 및 메커니즘 규명에 대한 연구는 별로 이루어지고 있지 않다. 따라서, 본 고에서는 상대적으로 위험성이 큰 지상식 LPG 저장탱크의 BLEVE 가능성에 대해 외국의 Pilot 탱크 시험 결과 및 BLEVE 발생을 위한 소요입열량 계산값을 이용한 연역적 계산방법을 통해 BLEVE 조건 및 가능성을 정량화하여 규명코자 하였다. 또한, 산출된 탱크의 파열압력(burst pressure)과 충전량에 의해 보정된 액 온도를 사용해서 그려진 BLEVE map을 이용하여 BLEVE 조건에서 액위($\%$)가 BLEVE에 어떤 영향을 미칠 것인가를 규명하였다. 계산결과, 탱크 plate 온도가 $600^{\circ}C$이고, 탱크내부 액온도가 $53^{\circ}C$ 일 때 액충전량은 $43.68\%$ 이상일 경우에 BLEVE의 발생이 가능하다는 결과를 얻었다. 또한, 부천 대성에너지 LPG 충전소와 동일한 사양인 15톤 프로판 탱크를 모델로 하여 BLEVE가 발생하기 위한 외부 누출 및 외부화재 조건을 PHAST(Version 6.00) 및 EFFECTS(Version 2.1) 프로그램을 이용해 계산한 결과 액상 누출시 누출상당직경은 7.2mm, 이상 누출시 누출상당직경은 17.6mm 이상일 경우에 BLEVE가 발생 가능한 최소한의 풀화재 생성조건이 되었고, 풀화재의 크기는 최소 직경 3.3m, 높이 10.4m 이상의 풀화재가 전제되어야 한다는 결과를 얻을 수 있었다.

  • PDF