• Title/Summary/Keyword: Pressure Hole

Search Result 756, Processing Time 0.024 seconds

Effect of Nozzle Hole Number on Atomization Characteristics of DME Fuel Spray using High Pressure Injector (고압 인젝터의 노즐 홀 수가 DME 연료분무의 미립화 특성에 미치는 영향)

  • Lee, Jongtae;Lee, Sanghoon;Chon, Mun Soo
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.216-220
    • /
    • 2014
  • This paper presents effect of nozzle hole number on atomization characteristic of DME fuel spray using three different type of injector having the hole number of 6, 7 and 8. For this study, PDPA(phase Doppler particle analyzer) experiment was performed in terms of $T_{ASOE}$ under various injection pressure. To compare general trend of atomization characteristic, the law data were ensemble averaged based on $T_{eng}$ of 0.2 ms. Results showed that the droplet diameter in terms of SMD(Sauter Mean Diameter) was reduced as increase in injection pressure. Increasing the number of hole lead to reduce in droplet diameter, but no significant reduction in diameter was observed between hole number of 7 and that of 8. In addition, increasing the number of hole resulted in decrease in droplet velocity which is considered as the effect of reduction in spray momentum due to decreasing of fuel quantity per each hole.

A Study on the Wide Reach Nozzle of Sprayer(IV) (Characteristics of cap hole diameter and pressure for the medium range nozzle) (휴반용 분무기의 Nozzle에 관한 연구(IV) (중거리용 Nozzle예 있어서 구경과 압력의 특성))

  • 옹장우;이상우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3872-3877
    • /
    • 1975
  • This study was conducted to examine the effects of the change of cap hole diameter and pressure on the travelling distance and the sprayed particle size for the medium range nozzle. The results of this study are summarized as follows; 1) The effective travelling distance was about from 1 meter to 8 meters and centro-position of the travelling distance was about 3 or 5 meters. 2) Main effect of change of cap hole diameter for the travelling distance was a slight convex quadratic curve. 3) Main effect of change of pressure increased linearly, its increasing rate about 1.6 was large. 4) Sizes of sprayed particles were less than 250${\mu}$ generally and the sizes decreased according to the increasing of travelling distance. 5) Changes of diameter of sprayed particles by cap hole diameter increased in accordance with increasing of cap hole diameter. 6) Changes of diameter of sprayed particles by the groove depth of swirl plate was very slight.

  • PDF

The Effect of Valve Geometry Variation on Injection Characteristics of Injection Valve for Marine Diesel Engines (선박디젤기관용 분사밸브의 형상변화가 분사특성에 미치는 영향에 관한 계산적 고찰)

  • Park, K.;Kim, S.Y.;Choi, C.W.
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.24-34
    • /
    • 2005
  • Injection technology is one of the important technologies in a diesel engine. Many studies have done on the injection system. In this study, the fuel chamber geometry, the orifice ratio and the needle lift of the injection valve for a marine diesel engine are varied, and simulated. The result shows that the nozzle hole size has influence on the rail pressure and injection duration sensitively. The decrease of the static pressure at the nozzle hole entrance and the increase of the dynamic pressure on the outlet surface are occurred with the increase of the nozzle hole diameter. The highest dynamic pressure of the outlet was occurred at the needle lift of 0.4mm and the nozzle hole diameter of 0.328mm in this test nozzle.

  • PDF

The Performance Assessment of a Straight-Type Five-Hole Pressure Probe Using a Zone Partition and Two-Dimensional Curve-Fitting Functions (영역분할과 2차원 커브피팅 함수들을 이용하는 직선형 5공 압력프로브의 성능 평가)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.22-31
    • /
    • 2014
  • This paper introduced the new calibration algorithm of a straight-type five-hole pressure probe necessary for calculating three-dimensional flow velocity components. The new velocity data reduction method using both a commercial two-dimensional curve-fitting program and the zone partition method of a calibration map was firstly introduced in this study. This new calibration method can be applied up to the wide flow angle of ${\pm}80^{\circ}$ despite of using a five-hole pressure probe because this data reduction method showed a comparatively good performance in calculating yaw and pitch angles from the calibration map.

Comparative Study on the Film Cooling Effectiveness of 15° Angled Anti-Vortex Hole and 30-7-7 Fan-Shaped Hole Using PSP Technique (PSP를 이용한 15° 반와류 홀과 30-7-7 팬형상 홀의 막냉각 효율 비교 연구)

  • Kim, Ye Jee;Park, Soon Sang;Rhee, Dong Ho;Kwak, Jae Su
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.4
    • /
    • pp.13-18
    • /
    • 2016
  • The various film cooling hole shapes have been proposed for effective external cooling of gas turbine blade. In this study, the film cooling effectiveness by three different hole shapes (cylindrical hole, $15^{\circ}$ angle anti-vortex hole, 30-7-7 fan-shaped hole) were examined experimentally. Pressure Sensitive Paint (PSP) technique was used to measure the film cooling effectiveness. The coolant to mainstream density ratio was 1.0 and three blowing ratios of 0.5, 1.0, and 2.0 were considered. Results clearly showed that the effect of hole shape on the distribution of film cooling effectiveness. For the cylindrical hole case, the film cooling effectiveness decreased remarkably as the blowing ratio increased due to the jet lift off. Because of large hole exit area and low coolant momentum, the 30-7-7 fan-shaped hole case showed the highest film cooling effectiveness at all blowing ratio, followed by the anti-vortex hole case.

Effect of Anti-Vortex Hole Angle on the Flat Plate Film Cooling Effectiveness (반와류 홀의 각도가 평판의 막냉각 효율에 미치는 영향 연구)

  • Park, Soon Sang;Park, Jung Shin;Lee, Sang Hoon;Moon, Young Gi;Kwak, Jae Su
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.5-10
    • /
    • 2014
  • In this paper, the experimental study was carried to investigate the effect of angle of the anti-vortex holes on the film cooling effectiveness on a flat plate. The pressure sensitive paint technique was applied to measure the film cooling effectiveness. Two anti-vortex hole angles of $0^{\circ}$ and $15^{\circ}$ with respect to the primary hole were considered, and the simple cylindrical hole case was also tested. The blowing ratio based on the cylindrical hole was 0.5 and the same flow rate was kept for all anti-vortex hole cases. Results showed that the film cooling effectiveness for the anti-vortex hole cases were much higher than that of the cylindrical case. Among the anti-vortex hole cases, $15^{\circ}$ angle anti-vortex hole case showed higher film cooling effectiveness than that by the $0^{\circ}$ angle anti-vortex hole case.

BEHAVIOR OF LIQUID LPG SPRAY INJECTING FROM A SINGLE HOLE NOZZLE

  • PARK K.
    • International Journal of Automotive Technology
    • /
    • v.6 no.3
    • /
    • pp.215-219
    • /
    • 2005
  • Liquefied petroleum gas (LPG) has been used as motor fuel due to its low emissions and low cost. A liquid direct injection system into a cylinder was suggested as a next generation system to maximize a fuel economy as well as a power. This study addresses the analysis of the LPG spray injecting from single hole injector. Two different test conditions are given, which are a fully developed spray case with various injection pressures and a developing spray case with ambient pressure variation. The LPG spray photographs are compared with the sprays of gasoline and diesel fuel at the same conditions, and the spray angles and penetration lengths are also compared, and then the spray behavior is analyzed. The LPG spray photos show that the dispersion characteristic depends very sensitively on the ambient pressure soon after injection. The spray angle is very wide in a low ambient pressure condition until the saturated pressure, but the angle is quickly reduced at the condition over the pressure. However, the down stream of the LPG spray shows much wider dispersion and less penetration than those of gasoline and diesel sprays regardless ambient pressure condition.

Development of five-hole probe nulling method reliable in complex flow field (복잡한 유동장에서도 신뢰성 있는 5공프로브 널링기법의 개발)

  • Kim, Jin-Gwon;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.11
    • /
    • pp.1449-1457
    • /
    • 1997
  • Since a non-nulling method of five-hole probes is valid only when the flow angle is within the calibrated angle range, it can not be used in a complex flow field. Full angle range pressure coefficient maps show that widely used nulling methods do not guarantee correct alignment of the probe with the flow direction in the unknown complex flow field. Zone decision method and features of zone map were studied by investigating the full angle range pressure coefficient maps. A reliable and efficient new nulling algorithm using zone decision by pressure ordering is proposed and verified. Since the zone decision method by pressure ordering can decide whether the flow is within the calibration angle range or not, it is useful in wide angle nonnulling methods, too.

Resistance to Air Flow through Packed Fruits and Vegetables in Vented Box (상자포장 청과물의 송풍저항 특성)

  • 윤홍선;조영길;박경규
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.351-359
    • /
    • 1995
  • In pressure cooling system, produce were packed in vented box and cooled rapidly by producing a difference in air pressure on opposite faces of stacks of vented box. So, energy requirements and performance of pressure cooling system depended upon the air flow rate and the static pressure drop through packed produce in vented box. The static pressure drop across packed produce in vented box normally depended upon air flow rate, vent area of box and conditions of produce bed (depth, porosity, stacking patterns, size and shape of products) in box. The objectives of this study were to investigate the effect of vent area and air flow rate on airflow resistance of empty box and packed produce in vented box, and to investigate the relationship between the air flow resistance of packed products in vented box and sum of air flow resistance of empty box only and products in bulk only. Mandarins and tomatoes were used in the experiment. The airflow rate were in the range of 0.02~1.0$m^3$/s.$m^2$, the opening ratio of vent hole were in the range of 2.5~20% of the side area. The results were summerized as follows. 1. The pressure drops across vented box increased in proportion to superficial air velocity and decreased in proportion to opening ratio of vent hole. A regression equation to calculate airflow resistance of vented box was derived as a function of superficial air velocity and opening ratio of vent hole. 2. The pressure drops across packed produce in vented box increased in proportion to superficial air velocity and decreased in proportion to opening ratio of vent hole. 3. Because of the air velocity increase in the vicinity of vent hole in box, the airflow resistances of packed products in vented box were always higher than sum of air flow resistance of empty box only and products in bulk only. 4. Based on the airflow resistance of empty box and products in bulk, a regression equation to calculate airflow resistance of packed products in vented box was derived.

  • PDF

Condensation oscillation characteristic of steam with non-condensable gas through multi-hole sparger at low mass flux

  • Dandi Zhang;Lili Tong;Xuewu Cao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.780-791
    • /
    • 2023
  • To study oscillation characteristic of steam and non-condensable gas direct contact condensation through multi-hole sparger at low mass flux, a series of experiments of pure steam and mixture gas condensation have been carried out under the conditions of steam mass flux of 20-120kg/m2s, water temperature of 20-95 ℃ and mass fraction of non-condensable gas of 0-5%. The regime map of pure steam condensation through multi-hole sparger is divided into steam chugging, separated bubble, aggregated bubble and escaping aggregated bubble. The bubbles behavior of synchronization in the same hole columns and desynchronized excitation between different hole columns can be found. The coalescence effect of mixture bubbles increases with water temperature and non-condensable gas content increasing. Pressure oscillation intensity of pure steam condensation first increases and then decreases with water temperature increasing, and increases with steam mass flux increasing. Pressure oscillation intensity of mixture gas condensation decreases with water temperature and non-condensable gas content increasing, which is significantly weaker than that of pure steam condensation. The oscillation dominant frequency decreases with the rise of water temperature and non-condensable gas content. The correlations for oscillation intensity and dominant frequency respectively are developed in pure steam and mixture gas condensation at low mass flux.