• 제목/요약/키워드: Pressure Guidance

Search Result 114, Processing Time 0.028 seconds

Studies on Starting Transient in Solid Rockets

  • V.R. Sanal Kumar;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.6-10
    • /
    • 2003
  • Accurate description of starting transient history allows and justifies the use of small margin of safety for the engine parts, resulting in high motor mass ratio in addition to satisfying the control and guidance requirements of the vehicle. Studies have been carried out for the prediction and reduction of ignition peak and pressure-rise rate during the starting transient of solid rocket motors. Numerical studies have been carried out using a two dimensional Navier-Stokes solver. It has been inferred through the parametric studies that, in the case of solid rocket motors with uniform port, high ignition peak is observed at high spread rate and low pressure-rise rate. In the case of the port with sudden expansion configuration, high ignition peak is observed at relatively high average spread rate and high-pressure rise rate. These studies are expected to aid the designer in reducing the ignition peak by altering the propellant properties or igniter characteristics without sacrificing the motor performance.

  • PDF

Simulation of Transient Flow in a Cold-Water Supply System with Pressure Reducing Valves for Cooling the Inside of a Coal Mining Pit (감압밸브를 사용한 탄광갱내 공조용 냉수 공급시스템의 과도현상 해석)

  • Kang, S.H.;Lee, T.S.;Lee, S.S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.395-407
    • /
    • 1988
  • Transient flow in a cold-water supply system for cooling the inside of a coal mining pit was numerically simulated. Properly designed and presetted pressure reducing valves control the level of pressures of the piping system at normal or emergent conditions Quasi-steady relations to simulate the valve motion are obtained and the transient performance of the valve is investigated in the present paper. The present method reasonably simulate transient phenomena in the system including the pressure reducing valve. Excessive valve motion and column separation are simulated when the flow is abruptly reduced. A calculated example of the real system is also presented. The simulation can be used for the safety-check and the guidance for design and operation in emergent cases of the system.

  • PDF

Sensitivity Analysis of Initial Pressure and Upper Control Limit on the Pressure Decay Test for Membrane Integrity Evaluation (압력손실시험을 이용한 막 완결성 평가에서 초기압력 및 UCL 도출인자 민감도 분석)

  • Lee, Joohee;Hong, Seungkwan;Hur, Hyunchul;Lee, Kwangjae;Choi, Youngjune
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.793-800
    • /
    • 2008
  • Recently domestic drinking water industry has recognized membrane-based technology as a promising alternative for water treatment. To ensure successful application of membrane processes, the integrity of membrane systems should be maintained. According to US EPA guidance, the pressure decay test based on the bubble point theory is recommended to detect any membrane defection of which size is close to the smallest diameter of Cryptosporidium oocysts, $3{\mu}m$. Proper implementation of the pressure decay test is greatly affected by initial test pressure, and the interpretation of the test results is associated with upper control limit. This study is conducted to investigate various factors affecting determination of initial test prtessure and upper control limit, including membrane-based parameters such as pore shape correction factor, surface tension and contact angle, and system-based parameters, such as volumetric concentration factor and total volume of system. In this paper, three different hollow fibers were used to perform the pressure decay test. With identical initial test pressure applied, their pressure decay tendency were different from each other. This finding can be explained by the micro-structure disparity of those membranes which is verified by FESEM images of those membranes. More specifically, FESEM images revealed that three hollow fibers have asymmetry, deep finger, shallow finger pore shape, respectively. In addition, sensitivity analysis was conducted on five parameters mentioned above to elucidate their relation to determination of initial test pressure and upper control limit. In case of initial pressure calculation, the pore shape correction factor has the highest value of sensitivity. For upper control limit determination, system factors have greater impact compared to membrane-based parameters.

The Numerical Simulation of the Pressure wave for G7 Test Train in the Tunnel (G7 시제 차량의 터널내부 압력파에 대한 수치 해석)

  • 권혁빈;김태윤;권재현;이동호;김문상
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.4
    • /
    • pp.260-266
    • /
    • 2002
  • A numerical simulation has been performed to estimate the transient pressure variation in the tunnel when G7 test train passes through the test tunnel in the Kyoeng-Bu high-speed railway. A modified patched grid scheme is developed to handle the relative motion between a train and a tunnel. Also, a hybrid dimensional approach is proposed to calculate the train-tunnel interaction problem efficiently. An axi-symmetric unsteady Euler solve using the Roe's FDS is used for analyzing a complicated pressure field in tunnel during the test train is passing through the tunnel. Usually, this complex phenomenon depends ell the train speed, train length, tunnel length, blockage ratio between train and tunnel cross-sectional area, relative position between train and tunnel, etc. Therefore, numerical simulation should be done carefully in consideration of these factors. Numerical results in this study would be good guidance to make test plans, test equipments selection and to decide their measuring locations. They will also supply important information to the pressurization equipment for high-speed train.

Performance of NACA 65-810 Radial Airfoil Impellers (NACA 65-810 반경류 에어포일 임펠러의 성능특성)

  • Kang, Shin-Hyoung;Hu, Shengli
    • The KSFM Journal of Fluid Machinery
    • /
    • v.1 no.1 s.1
    • /
    • pp.24-31
    • /
    • 1998
  • Aerodynamic performance tests and flow measurement were carried out for several radial impellers of NACA 65-810 airfoil. The data base obtained are to be used for verifying the methods of flow analysis and CFD codes. The effects of numbers and span of blades on the performances, efficiency and impeller exit flow are investigated in the present study. The flow rate on the performance curve is proportional to the span of the blade for the same value of fan pressure rise. The magnitude of radial velocity component at the impeller exit gradually decreases from the hub to shroud side. The magnitude of tangential velocity component gradually increases from the hub to shroud side. The way of variations of velocity is the same at the diffuser exit, however, becomes more uniform. The pressure rise performance increases with blade number at the small flow coefficients, however, decreases with the number of blade at the large flow coefficients. This shows that flow guidance in important at the low flow rate and the friction becomes significant at the high flow rate.

  • PDF

A Study on Outlet of Draft Pattern for Equal Pressure Method Underfloor Air Distribution System (등압식 바닥 분출공조시스템의 기류 분출 상태에 관한 연구)

  • Choi, Young-Sik;Son, Won-Tug
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.2
    • /
    • pp.29-33
    • /
    • 2013
  • This study has been conducted to propose an optimal design guidance of underfloor air distribution system by examining air pattern and proper exhaust status of floor plenum using CFD (Computational Fluid Dynamics). Simulation shows deficient air pattern and exhaust status at BPG (Bypass Grille) of the current design. As a means to find an alternative design, four cases have been developed and tested. Case 1, 2 and 3 show similar results in comparison to the current design. However, case 4 shows improved air pattern and exhaust status at BPG(Bypass Grille), and has been chosen as the optimal alternative.

Effects of the initial charging pressure of gas on the cool-down characteristics of the Joule-Thomson cryocooler (초기충전압력이 쥴톰슨냉동기의 강온에 미치는 영향)

  • Hong, Yong-Ju;Park, Seong-Je;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2160-2164
    • /
    • 2008
  • Miniature Joule-Thomson cryocoolers have been widely used for rapid cooling of infrared detectors, probes of cryosurgery, thermal cameras, missile homing head and guidance system, due to their special features of simple configuration, compact structure and rapid cool-down characteristics. The cool-down time, the temperature at the cold end, the running time and the gas consumption are the important indicators of the performance of the J-T cryocooler. In this study, the initial cool-down stages of the J-T cryocooler were investigated by numerical simulations. The results show the effects of the initial charging pressures of gas on the cool-down time and the temperature at the cold end and the gas consumptions.

  • PDF

Development of Pressure Ulcer Management Guideline by Adaptation Process (수용개작방법을 활용한 욕창간호 실무지침 개발)

  • Jeong, Ihn Sook;Kim, Shinmi;Jeong, Jae Sim;Hong, Eun Young;Lim, Eun Young;Seo, Hyun Ju;Park, Kyung Hee;Hong, Yong Eun;Hwang, Ji Hyeon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.20 no.1
    • /
    • pp.40-52
    • /
    • 2014
  • Purpose: This study was done to develop an evidence-based nursing clinical practice guideline (PU CPG) for pressure ulcer prevention and management in Korea. Methods: The guideline adaptation process was used and conducted according to the guideline adaptation manual developed by Gu et al. (2012) which consists of three main phases and 9 modules including a total of 24 steps. Results: The newly developed PU CPG included the introduction, pressure ulcers, summary of recommendations, recommendations, references, appendices, and glossary. The total number of recommendations was 148 in 4 sections (organizational policy, assessment, pressure ulcer prevention and management, and education) and 16 domains. Of the recommendations 4.7% were graded A, 16.9%, B, and 78.4%, C. Conclusion: Results indicate that this new PU CPG is an evidence-based practice guidance for pressure ulcer prevention and management and can be recommended for dissemination and utilization by nurses nationwide to improve the quality of pressure ulcer prevention and management. Regular revision is recommended.

A Study on the Analysis of the Elevation Blockage Ratio in the Conservation of the Coastal Landscape of Jeju (제주시 해안일주도로의 경관보전을 위한 건축물의 입면차폐도 분석에 관한 연구)

  • Park, Chul-Min;Kim, Sung-Hoon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.6 no.2
    • /
    • pp.31-42
    • /
    • 2004
  • Although the coastal area of Jeju has already been developed, it has high pressure and demands for development continually increasing due to the increase of tourism and leisure activities. Therefore, the purpose of this study is to present objective guidance for the planning of the buildings on the seaside road with a view which have the largest impact on coastal landscape in order to enhance its visual quality. The results of this study are as follows : 1) It is chief element to make guidance for the use and planning of buildings in the conservation of the coastal landscape. 2) The D/H ratios which immediately influence an angle of elevation are different one another for the whole street. To ensure a sense of openness for the landscape, it is needed to maintain under $27^{\circ}$ angle of elevation, which demands 1~3 D/H ratio. 3) It is important to make 2.4 visual blockage ratio for whole street, but the actual condition is 4.48 ratio on average. To bring down the visual blockage ratio, the W/D ratio needs to be regulated. 4) Various techniques are also needed for lively building styles going with coastal landscape.

  • PDF

Study on Ovum Pick-up(OPU) with Finger-Sensibility using Oocyte Recovery in Holstein Heifers (젖소에서 초음파기기를 이용한 난자 채취에 있어서 손가락 촉지를 이용한 난포란의 채란)

  • 진종인;홍승표;정장용;이지삼;박희성
    • Journal of Embryo Transfer
    • /
    • v.15 no.3
    • /
    • pp.279-286
    • /
    • 2000
  • This study was conducted to develop an improved method for oocyte pick-up(OPU) with finger-sensibility using ultrasound-guidance from ovarian follicles in Holstein heifers. Oocytes were aspirated from ovarian follicles of clear-outline (>2mm), obscure-outline and invisible($\leq$ 2mm) on ultrasound images with 3 different vacuum pressure(40, 80, 120mmHg). Total number of oocytes recovered/follicles were 309/237(130.4%). 113/80(141.3%) and 107/74(144.6%) with 40, 80 and 120 mmHg of vacuum pressure, respectively. Mean number of oocytes recovered was higher in 2 OPU/week (18.3$\pm$5.3) than 1 OPU/week(14.5$\pm$4.1), but this difference was not statistical1y significant. The recovery rates were not affected by the number of OPU as 135.6%(282 oocytes/208 follicles) in 1~20 OPU, 137.7% (168/122) in 21~40 OPU and 148.4%(92/62) in 41~60 OPU, respectively. The proportions of good oocytes (Grades I) recovered were not significantly different by the number of OPU until 40 OPU(12.4% in 1~20 OPU vs 16.7% in 21~40 OPU). However, a significantly(P<0.05) lower recovery rate resulted from more than 40 OPU compared to less than 40 OPU(7.6%). These results imply that more fertilizable oocytes can be produced from invisible-immature follicles by transvaginal aspiration with finger-sensibility from Holstein heifers.

  • PDF