• Title/Summary/Keyword: Pressure Exchange

Search Result 388, Processing Time 0.022 seconds

Heat Exchange Charaterictics of Water under the Low Pressure by driving Ejector (에젝터 구동 저압 증발하에서 물의 열교환 특성)

  • Shin, Yu-Sik;Lee, Youn-Hwan;Lee, Sang-Chul;Kim, Se-Hyun;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1885-1890
    • /
    • 2003
  • The cooling tower is a device for making a cooling water in the air conditioning system of building, and there are many kinds of cooling tower system for air conditioner. In this paper, we introduced the water cooling system with an enclosed tank and water ejecting system for evaporating the water in tank. The city water was used for a working fluid, and the cooling water is generated by evaporating latent heat in the tank with a $25{\sim}50mmHg$. The time to reaching this vacuum pressure was about $20{\sim}30minutes$, and cooling water was obtained the value of temperature difference ${\Delta}T=7^{\circ}C$.

  • PDF

Fabrication of Stable Water/Oil Separation Filter Using Effect of Surface Wettability (표면 젖음성을 이용한 물/오일 분리막 제작)

  • Kim, Dohyeong;An, Taechang
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.213-217
    • /
    • 2016
  • The superhydrophobic and superoleophobic meshes surfaces have been used in various applications such as self-cleaning, anti-icing, gas exchange, oil-water separation, sound-wave penetrable anti-wetting structures, etc. In particular, there are many studies for oil-water separation with environmental issues. Because of high pressure and dynamic environment, oil-water separation filters must have stable surface properties as super-hydrophobicity and superoleophobicity. The oleophobicity of surface depends on the surface chemistry and roughness of the surface. The roughness of oleophobic surface enhances its static contact angle and stability. The multi-scale hierarchical structure provides a stable superhydrophobic state by maintaining a Cassie state. In this research, we fabricated a superoleophobic mesh with a multi-scale hierarchical structure to increase the pressure resistance and adjusted a size of the mesh hole.

Multiphase Flow Modeling of Molten Material-Vapor-Liquid Mixtures in Thermal Nonequilibrium

  • Park, Ik-Kyu;Park, Goon-Cherl;Bang, Kwang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.553-561
    • /
    • 2000
  • This paper presents a numerical model of multi phase flow of the mixtures of molten material-liquid-vapor, particularly in thermal nonequilibrium. It is a two-dimensional, transient, three-fluid model in Eulerian coordinates. The equations are solved numerically using the finite difference method that implicitly couples the rates of phase changes, momentum, and energy exchange to determine the pressure, density, and velocity fields. To examine the model's ability to predict an experimental data, calculations have been performed for tests of pouring hot particles and molten material into a water pool. The predictions show good agreement with the experimental data. It appears, however, that the interfacial heat transfer and breakup of molten material need improved models that can be applied to such high temperature, high pressure, multi phase flow conditions.

  • PDF

The Simulation of PEMFC System Performance for Automotive Application (1) (작동조건을 고려한 자동차용 PEM 연료전지 시스템 성능 시뮬레이션 (1))

  • Bang, Jung-Hwan;Kim, Han-Sang;Lee, Dong-Hun;Min, Kyoung-Doug;Kim, Min-Soo;Cho, Young-Man
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.460-465
    • /
    • 2003
  • The modeling of PEM (Proton Exchange Membrane) fuel cell system consisting of fuel cell stack and BOP (Balance of Plant) is presented in this paper. The effects of temperature, pressure (air, hydrogen), and humidity on the fuel cell system performance were mainly investigated using thermo-dynamical and electro-chemical equations. To understand the power distribution characteristics of fuel cell system, the effects of operating temperature and air pressure on maximum power and system power were also demonstrated. Through this study, we can get the basic insight into the fuel cell stack and BOP component sizing and it can be used effectively for the optimization of the practical fuel cell systems in purpose.

  • PDF

Synthesis of spherical silica aerogel powder by emulsion polymerization technique

  • Hong, Sun Ki;Yoon, Mi Young;Hwang, Hae Jin
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc1
    • /
    • pp.145-148
    • /
    • 2012
  • Spherical silica aerogel powders were fabricated via an emulsion polymerization method from a water glass. A water-in-oil emulsion, in which droplets of a silicic acid solution are emulsified with span 80 (surfactant) in n-hexane, was produced by a high power homogenizer. After gelation, the surface of the spherical silica hydrogels was modified using a TMCS (trimethylchlorosilane)/n-hexane solution followed by solvent exchange from water to n-hexane. Hydrophobic silica wet gel droplets were dried at 80 ℃ under ambient pressure. A perfect spherical silica aerogel powder between1 to 12 ㎛ in diameter was obtained and its size can be controlled by mixing speed. The tapping density, pore volume, and BET surface area of the silica aerogel powder were approximately 0.08 g·cm-3, 3.5 ㎤·g-1 and 742 ㎡·g-1, respectively.

Shortening of Nursing Record Time about Real Time Transmission Effect of Blood Pressure, Blood Glucose Value Based on U-Healthcare (유-헬스케어 기반 실시간 혈압, 혈당 측정치 전송의 간호기록 시간 단축)

  • Park, Jeong-Eun;Kim, Hwa-Sun;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.4
    • /
    • pp.164-172
    • /
    • 2013
  • Purpose: The aim was to measure the real-time trans-mission effect of blood-pressure and blood-glucose value based on u-healthcare for saving the time and effort of nursing recording time. Methods: This study used a u-healthcare system based on the international standards for the exchange of health information. In order to verify the effectiveness of the u-healthcare, a clinical trial for the system regarding blood-pressure and blood-glucose targeting of patients with endocrine disorders at KNUH from February 7 to 9, 2012 was performed. Results: According to the analyzed results, of the 86 times the 11 patients were tested, measuring blood-pressure and blood-glucose using the u-healthcare system, we found the time differences between the real-time transfer recording method and existing hospital records that were used in the hospital. Based on the average time interval, there was a difference of 1,090.45 seconds (18.17 minutes). Conclusion: Therefore, it's cumbersome that nurses in the hospital have to record the numerical values of the measured blood-pressure and blood-glucose manually and input the recorded values directly into the electronic nursing record system. However, it was found in terms of the newly designed system, that it could save time and effort for nurses, since measured information is sent to the hospital information system on a real-time basis.

Comparison between CFD Analysis and Experiments According to Various PEMFC Flow-field Designs

  • Lee, Kang-In;Lee, Se-Won;Park, Min-Soo;Cho, Yong-Hun;Cho, Yoon-Hwan;Chu, Chong-Nam;Sung, Yung-Eun
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in five kinds of flow-field designs, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, a single cell test was carried out to obtain the performance values. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. The single serpentine configuration gave the highest performance because of the high pressure difference magnitudes of the inlet/outlet. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.

Study on the Characteristics of Methanol Steam Reformer Using Latent Heat of Steam (수증기의 잠열을 이용한 메탄올 수증기 개질기의 특성 연구)

  • CHEON, UKRAE;AHN, KANGSUB;SHIN, HYUNKHIL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.19-24
    • /
    • 2018
  • Fuel cells are used to generate electricity with a reformer. In particular, methanol has various advantages among the fuels for reformer. Methanol steam reformer devices can efficiently supply hydrogen to PEM fuel cell. This study investigated the optimal operation conditions of a methanol steam reforming process. For this purpose, aspen HYSYS was used for the optimization of reforming process. The optimal operating condition could be designed by setting independent variables such as temperature, pressure and steam to carbon ratio (SCR). The optimal temperature and steam to carbon ratio were $250-270^{\circ}C$ and 1.3-1.5, respectively. It is advantageous to operate at a pressure of 15-20 barg, considering the performance of the hydrogen purifier. In addition, a heat exchange network was designed to supply heat constantly to reformer through the latent heat of steam.

Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control (실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발)

  • Choi, Sun-Young;Lee, Young-Kug;Choi, Myeong-Gwang;Choi, Tae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.

A Study on the Pressure Variation of Intake Pipe and the Volumetric Efficiency in a Multi-Cylinder Engine (다실린더기관 흡기관내의 압력변동과 체적효율에 관한 연구)

  • 서정일;조진호;김형섭;김병주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.179-188
    • /
    • 1990
  • The characteristic of volumetric efficiency considering gas exchange process in a reciprocating engine is presented in this paper. The characteristic method is used for solving gas exchange problems of engine system in theoretical studies. The validity of the simulation is investigated by a comparison with the results obtained by the experiment which have been performed on the practical 4-cycle, 4-cylinder gasoline engine. The relationship between the volumetric efficiency and the intake pressure variation according to configuration of intake pipe, position of branch point, valve timing, compression ratio is clarified through simulation and experiment. The results predicted by the simulation are found to be in approximate agreement with those obtained by the experiment.