• Title/Summary/Keyword: Pressure Equalization

Search Result 21, Processing Time 0.027 seconds

Process optimization of PSA way Oxygen Concentrator for Electric Power Saving (전력 절감을 위한 PSA방식의 산소 발생기 공정 최적화)

  • Chi, Seok-Hwan;Lee, Moon-Kyu;Lee, Tae-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1350-1354
    • /
    • 2007
  • As the importance of low power design is emphasized, power consumption became one of the standards that represent the performance of the system. The purpose of this study is to decide design variable that minimize power consumption for the oxygen concentrator in two bed-one compressor 8 step PSA process that has above 90% purity at 3lpm by using given constants and selected parameters. Setting selected parameters as cycle time and equalization time, optimization for PSA process in the oxygen concentrator is progressed. For this, we need to know the features and basic principals of PSA process and to deduce objective function of performance analysis. Validations for objective function and lots of experiments are needed too. By using the characteristic curve of the compressor and the pressure curve of the process for 1 cycle, objective function was set. After theoretical 2 dimensional optimized paths was obtained. And then, by experiment, theoretical optimized path was verified.

  • PDF

Aerodynamic Methods for Mitigating the Wind-Induced Motions on the Tall Buildings (고층건축물의 풍진동 저감을 위한 공기역학적 방법)

  • Ha Young-Cheol;Kim Dong-Woo
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.431-434
    • /
    • 2002
  • The excessive wind-induced motion of tall buildings most frequently result from vortex shedding induced across-wind oscillations. This form of excitation is most pronounced far relatively flexible, lightweight and lightly damped structure, e.g. tall building. This paper discusses aerodynamic means for mitigating the across-wind vortex shedding induced in such situations. Emphasis is on the change of the building cross section to design the building with openings from side to side which provide pressure equalization and tend to reduced the effectiveness of across-wind forces by reducing their magnitudes and disrupting their spatial correlation. Wind tunnel test have been carried out on the Kumoh National University of Technology using rigid models with twenty-four kinds of opening shapes. Form these results, the effective opening shape, size and location for building to reducing wind-induced vortex shedding and responses are pointed out.

  • PDF

A Study on the Post Processing of Flash Boiling Spray Image from Shadowgraphy (감압비등 분무의 역광이미지 후처리 기법에 관한 연구)

  • Hyunchang Lee
    • Journal of ILASS-Korea
    • /
    • v.29 no.2
    • /
    • pp.91-97
    • /
    • 2024
  • When investigating the droplet, spray, and impact of liquid on a solid plate, backlight imaging has been widely used to understand these phenomena. However, some previous studies have suffered from poor image quality. In this study, various combinations of image processing algorithms, such as white image correction, histogram equalization, CLAHE, Otsu's binarization, and multi-Otsu's binarization, have been applied to flash boiling spray images to enhance image quality for qualitative observation and semi-quantitative spray angle evaluation. To acquire images with high contrast for qualitative observation, applying CLAHE was effective, making small droplets and detailed shapes of the jet noticeable. However, when images were averaged to determine spray angle or penetration length based on intensity, this method induced artifact unphysical patterns, thus requiring careful consideration. Based on the algorithm proposed in this study, the spray angle variation according to injection pressure and temperature has been calculated, showing a reasonable trend.

Development of PSA Process for Medical Oxygen Generator (의료용 산소발생기 제작을 위한 PSA 공정의 개발)

  • Choi, Jae-Wook;Na, Byung-Ki
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.75-80
    • /
    • 2009
  • In order to separate oxygen from air, the effects of feed gas flow rate and rinse gas flow rate on the product purity and flow were examined using 2 bed PSA with 4 step cycle. The addition of product pressurization step increased the product purity and flow rate. The addition of pressure equalization increased the product flow rate. The test product was manufactured and the purity and flow rate of product oxygen was examined. The results were compared with the commercial medical oxygen generator of 5 ${\ell}/min$ and 90% oxygen purity.

Comparison of PSA and VSA processes for air separation (공기 분리를 위한 O2 PSA (Pressure Swing Adsorption)공정과 VSA (Vacuum Swing Adsorption) 공정의 설게 및 성능 비교)

  • Lee, Sang Jin;Ahn, Hyungwoong;Jee, Jeung-Geun;Kim, Min-Bae;Moon, Jong-Ho;Bae, Yoon-Sang;Lee, Chang-Ha
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • PSA and VSA processes have been used broadly to produce oxygen from ambient air in midium- or small-sized plants. PSA and VSA processes are the separation methods which use difference of amount adsorbed as pressure is changed periodically, but they have the differences in pressurization and regeneration. In this study, the performance of 6-step PSA process was compared with that of 5-step VSA process with respect to purity and recovery. In addition, the effects of each step (pressurization step, adsorption step, and pressure equalization step) on purity and recovery were investigated. As a result, the VSA process using zeolite 10X showed better performance than the zeolite 5A PSA and zeolite 13X VSA process in comparison with purity, recovery and productivity. And it was enough to apply the vacuum pressure of 200 torr for the VSA, which produced over 90% oxygen with 70% recovery.

  • PDF

A Case Report of Primary Pericardial Malignant Epitheloid Mesothelioma (원발성 심막 악성 중배엽 상피종 1예)

  • Chung, Moon-Ho;Hyun, Myong-Su;Kim, Yeung-Cho;Shim, Bong-Sup;Kim, Chong-Sul;Lee, Dong-Hub;Lee, Chul-Ju;Kang, Myun-Sik
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.301-306
    • /
    • 1986
  • Primary pericardial mesothelioma is a rare tumor of mesodermal origin that is infrequently diagnosed antemortem and survival is short. A 60 year old male case of pericardial mesothelioma(epitheloid type) is reported. He was admitted to Yeungnam University Hospital because of chest pain, dyspnea, orthopnea and nonproductive cough. Chest x-ray suggested pericardial effusion, 2-D echocardiography showed echo free spaces of massive pericardial effusion and areas of thick hyperrefractile echoes arising from the pericardium. Pericardiocentesis was attempted and aspirated fluid was bloody exudate. Pericardial window operation with biopsy was done. Swan-Ganz catheterization showed equalization between right atrial pressure and pulmonary capillary wedge pressure. The pathologic diagnosis was established by histologic finding at pericardial biopsy.

  • PDF

Separation of $CH_4/CO_2/N_2$ Mixture by Pressure Swing Adsorption (PSA법을 이용하여 $CH_4/CO_2/N_2$ 혼합가스 중에서 메탄의 분리)

  • Cho, Woo-Ram;Jeong, Gu-Hyun;Shin, Young-Hwan;Yoo, Hee-Chan;Na, Byung-Ki
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2011
  • A compact adsorption-based process for removal of carbon dioxide and nitrogen from natural gas has been discussed. Among the adsorption-based processes, especially, the pressure swing adsorption (PSA) process has been a suitable unit operation for the purification and separation of gas because of low operation energy and cost. A step cycle is made up of pressurization, feed, equalization, blowdown and rinse. In this work, the PSA process is composed of zeolite 13X and carbon molecular sieve (CMS) for removal of carbon dioxide and nitrogen from mixed gas containing $CH_4/CO_2/N_2$ (75:21:4 vol%). A CMS selectively removes carbon dioxide and a zeolite 13X separates nitrogen from methane. CMS is investigated experimentally due to the high throughput of the faster diffusing component ($CO_2$). The gas composition of top, bottom and feed tank was measured with the gas chromatography (GC) using TCD detector, helium as carrier gas and packed column for analysis of methane, carbon dioxide, and nitrogen.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

A study on the experience of care managers - Approached Qualitative case study method - (사례관리자들의 실천경험 연구 - 질적사례연구 방법 접근 -)

  • Kim, Young-Sook;Lim, Hyo-Yeon;Shin, So-Ra
    • Korean Journal of Social Welfare Studies
    • /
    • v.40 no.2
    • /
    • pp.89-122
    • /
    • 2009
  • This study was carried out to analyze the job of care managers in their social welfare practicing fields about the frequency of care management duties they perform, types of duties considered to be most important and the reason, and types of jobs counted to be the most difficult and the reason by qualitative case study research methods. The job area of care management was elicited using DACUM method, and those 9 job areas derived from it were analysed according to frequency of performance, importance and difficulty. The subjects were 10 social workers serving more than 3 years with major duty of care management and chosen by reputational-case selection, and those collected data analysis was operated according to embedded analysis types. We discussed the implication of this research. : The experience of participants are the process of maintaining the tension, and search the equilibrium point between client centered service and institutional pressure. According to the results we proposed ① Construction of community based social work network, ② Institutional installation for guarantee care manager's Job competence ③ Standard manual for equilibrium and upward equalization

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Design and Operation Guideline (바이오가스 이용 기술지침 마련을 위한 연구(III) - 기술지침(안) 중심으로)

  • Moon, HeeSung;Bae, Jisu;Pack, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.95-103
    • /
    • 2018
  • As a guideline for desulfurization and dehumidification pretreatment facility for optimizing utilization of biogas, the $H_2S$ concentration is set at 150 % which can be treated with iron salts, dehumidification is the optimum value for generator operation, and the relative humidity applied at the utilization of biogas in EU is set at 60 %. We have set up the generator facility guidelines to optimize utilization of biogas. The appropriate amount of biogas should be at least 90 % of the total gas generation, and the capacity of generator facility should be set at 20~30 %. In order to equalize the pressure of the incoming gas the generator, a gas equalization tank should be installed and the generator room average temperature should be kept at $45^{\circ}C$ or less. Since the gas is not produced at a certain methane concentration in the digester, the efficiency is lowered. Therefore, it is required to install an air fuel ratio control system according to the change in methane concentration. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure), investigate the facilities problem and propose design, operation guidelines such as pre-treatment facilities and generators.