• Title/Summary/Keyword: Prediction#4

Search Result 6,508, Processing Time 0.037 seconds

Prediction of Post-operative Cardiopulmonary Function By Perfusion Scan (폐관류 검사를 이용한 폐절제술 후 심폐운동기능의 예측)

  • Ryu, Jeong-Seon;Lee, Ji-Young;Seo, Dong-Bum;Cho, Jae-Hwa;Lee, Hong-Lyeol;Yoon, Yong-Han;Kim, Kwang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.401-408
    • /
    • 2001
  • Background : Perfusion scans are accurate predictors of postoperative lung function. There are few previous studies aimed at predicting the postoperative exercise capacity using the perfusion scanning and those that did reported contradictory results. Method : We prospectively studied the preoperative spirometric, exercise tests and perfusion scans from in 49 consecutive patients who were admitted to Inha University Hospital with surgically resectable lung cancer from Jan. 1998 to Jun. 1999 29 patients who had any condition affecting the lung function and exercise capacity, or refused a surgical resection or a follow-up study were excluded. Spirometric and exercise tests were performed 6 months after operation in 20 patients. Results : The predicted postoperative $FEV_1$, FVC and TLC correlated well with the following corresponding postoperative values : $r_s$ and p value, 0.809 and 0.000 for the $FEV_1$ 0.895 and 0.000 for the FVC ; 0.741 and 0.006 for the TLC, respectively. The measured postoperative exercise values were slightly higher than the postoperative exercise values predicted, $VO_{2max}$ and $Wr_{max}$, were as 112% of $VO_{2max}$ predicted and 119% of $WR_{max}$ predicted. The change in $FEV_1$, FVC and TLC had a weak correlation with the change in $VO_{2max}$ and $WR_{max}$. Conclusion : The perfusion scan was a useful tool for predicting the postoperative exercise capacity. However, they had a tendency to underestimate the exercise capacity, especially in the patients who had a pneumonectomy. A weak correlation between the change in lung function and exercise capacity was observed.

  • PDF

Effect of Package Size and Pasteurization Temperature on the Quality of Sous Vide Processed Spinach (Sous Vide 가공 시금치의 품질에 미치는 포장단위 및 살균온도의 영향)

  • 장재덕;김기태;이동선
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.195-200
    • /
    • 2004
  • Microbial lethal value and nutrient retention of sous vide processed spinach were evaluated with mathematical model prediction and experimental trial for different package sizes and pasteurization temperatures. The package size covers 500 g, 1 kg and 2 kg, while the pasteurization temperature includes 80, 90 and 97$^{\circ}C$. The basic process scheme consists of filling blanched spinach into barrier plastic film pouch, sealing under vacuum, pasteurization in hot water with over pressure and final cooling to 3$^{\circ}C$. Pasteurization condition was designed based on attainment of 6 decimal inactivation of Listeria monocytogenes at geometric center of the pouch package by heating cycle, which was determined by general method. Heat penetration property of the package and thermal destruction kinetics were combined to estimate the retention of ascorbic acid and chlorophyll. Smaller packages with shorter pasteurization time gave better nutrient retention, physical and chemical qualities. Larger package size was estimated and confirmed experimentally to give higher pasteurization value at center, lower ascorbic acid and chlorophyll contents caused by longer heat process time. Lower pasteurization temperature with longer process time was predicted to give lower pasteurization value at center and lower ascorbic acid, while chlorophyll content was affected little by the temperature. Experimental trial showed better retention of ascorbic acid and chlorophyll for smaller package and higher pasteurization temperature with shorter heating time. The beneficial effect of smaller package and higher pasteurization temperature was also observed in texture, color retention and drip production.

A Study on Yunqi Climate (運氣氣候) through analysis of Meteorological research data in Korea (한국(韓國) 기상자료(氣象資料)의 분석(分析)을 통(通)한 운기(運氣) 기후(氣候)에 관(關)한 연구(硏究))

  • Park, Chan-Young;Kim, Ki-Wook;Park, Hyun-Kook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.1-24
    • /
    • 2000
  • The comparison of climate's character of Yunqi(運氣) with the data of meterological observation were made in the research of climate. 1. The comparison of the average velocity of wind, temperature, rainfall, humidity of Seoul, by late 1954 to 1983, with Yunqi(運氣) was made. Fire-Chi(火氣) and moisture-qi(濕氣) were matched with the attribute of Taiyun(大運). Cold-qi(寒氣) was had some relationship. Dry-qi(燥 氣) and Wind-qi(風氣) were not matched. About the relationship of Spirit-of-official-sky(司天之氣) with climate, when the Moisture-soil(濕土) was added, they were matched and when the King-fire(君火) was added, they have some relationship. But Wind-tree(風木), Dry-metal(燥金), Buble-fire(相火), Cold-water(寒水) was added they were not matched. 2. According to the observation data of rainfall by late 180 years of Seoul; about Taiyun(大運), when the Water-Yun(水運) was greatly exceeded and Fire-Yun(火運) was shorted, in the case of Official-sky(司天), when Wind-Tree(風木) was added, the frequency was highly. So when the Soil-Yun(土運) was greatly exceeded and when Official-sky(司天)was added to the Moisture-soil(濕土), the rainfall was not matched. 3. The relationship of the frequency of the abnormal climate occurrences between Yunqi-promotion-weak(運氣盛衰)and Yunqi-Harmony(運氣同化) and Yunqi-soft-attacking(運氣順逆) in the weather of Korean Peninsula was compared by 1564 to 1863. They were not matched except the case of Yunqi-Harmony(運氣同化). 4. There were some cases which were not matched exactly between the climate predicted by the theory and real climate in 1984, the year of Kap-ga(甲子年). But many correspondence between the observation by the office of meteorology and the prediction by the analysis from Yun-qi-sang-hab(運氣相合) theory. 5. Because meterological phenomena of real world and analysis from the hypothesis of Yunqi(運氣) have no relationship with each other, some of Doctor denied Yunqi(運氣) in the way of matching mechanically. But the thought of Doctor who denied Fortune-spirit(運氣) made promotion for the theory of divination by bringing deeper insight. And it was not only the negative side. 6. In the point of geographical difference, the climate of China, the origination Yunqi theory, is different from the Korea's. Thus some observation errors should be considered. From the basis of this thesis, I hope that the deeper advance would be made into the Korean Yunqi theory.

  • PDF

Personalized Exhibition Booth Recommendation Methodology Using Sequential Association Rule (순차 연관 규칙을 이용한 개인화된 전시 부스 추천 방법)

  • Moon, Hyun-Sil;Jung, Min-Kyu;Kim, Jae-Kyeong;Kim, Hyea-Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.4
    • /
    • pp.195-211
    • /
    • 2010
  • An exhibition is defined as market events for specific duration to present exhibitors' main product range to either business or private visitors, and it also plays a key role as effective marketing channels. Especially, as the effect of the opinions of the visitors after the exhibition impacts directly on sales or the image of companies, exhibition organizers must consider various needs of visitors. To meet needs of visitors, ubiquitous technologies have been applied in some exhibitions. However, despite of the development of the ubiquitous technologies, their services cannot always reflect visitors' preferences as they only generate information when visitors request. As a result, they have reached their limit to meet needs of visitors, which consequently might lead them to loss of marketing opportunity. Recommendation systems can be the right type to overcome these limitations. They can recommend the booths to coincide with visitors' preferences, so that they help visitors who are in difficulty for choices in exhibition environment. One of the most successful and widely used technologies for building recommender systems is called Collaborative Filtering. Traditional recommender systems, however, only use neighbors' evaluations or behaviors for a personalized prediction. Therefore, they can not reflect visitors' dynamic preference, and also lack of accuracy in exhibition environment. Although there is much useful information to infer visitors' preference in ubiquitous environment (e.g., visitors' current location, booth visit path, and so on), they use only limited information for recommendation. In this study, we propose a booth recommendation methodology using Sequential Association Rule which considers the sequence of visiting. Recent studies of Sequential Association Rule use the constraints to improve the performance. However, since traditional Sequential Association Rule considers the whole rules to recommendation, they have a scalability problem when they are adapted to a large exhibition scale. To solve this problem, our methodology composes the confidence database before recommendation process. To compose the confidence database, we first search preceding rules which have the frequency above threshold. Next, we compute the confidences of each preceding rules to each booth which is not contained in preceding rules. Therefore, the confidence database has two kinds of information which are preceding rules and their confidence to each booth. In recommendation process, we just generate preceding rules of the target visitors based on the records of the visits, and recommend booths according to the confidence database. Throughout these steps, we expect reduction of time spent on recommendation process. To evaluate proposed methodology, we use real booth visit records which are collected by RFID technology in IT exhibition. Booth visit records also contain the visit sequence of each visitor. We compare the performance of proposed methodology with traditional Collaborative Filtering system. As a result, our proposed methodology generally shows higher performance than traditional Collaborative Filtering. We can also see some features of it in experimental results. First, it shows the highest performance at one booth recommendation. It detects preceding rules with some portions of visitors. Therefore, if there is a visitor who moved with very a different pattern compared to the whole visitors, it cannot give a correct recommendation for him/her even though we increase the number of recommendation. Trained by the whole visitors, it cannot correctly give recommendation to visitors who have a unique path. Second, the performance of general recommendation systems increase as time expands. However, our methodology shows higher performance with limited information like one or two time periods. Therefore, not only can it recommend even if there is not much information of the target visitors' booth visit records, but also it uses only small amount of information in recommendation process. We expect that it can give real?time recommendations in exhibition environment. Overall, our methodology shows higher performance ability than traditional Collaborative Filtering systems, we expect it could be applied in booth recommendation system to satisfy visitors in exhibition environment.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph (성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교)

  • Jang, Min-Guk;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.312-323
    • /
    • 2011
  • Objective: This study compared the bone thickness of the palate between lateral cephalogram and 3D model measurements. Methods: The subjects consisted of 30 adults (15 men,15 women) with a normal skeletal pattern and occlusion. The CT images were transformed to a 3D model, and were compared with the cephalometric image. Descriptive statistics for each variable were calculated. Results: In the 3D CT model, the mid-palatal area was the thickest part. It became thinner as the palate tapered laterally. In the male group, the thinnest portion was positioned 6 mm away from the mid-palate, while in the female group the thinnest portion was 8mm away from the mid-palate. Correlation analysis between the lateral cephalometric and 3D CT model revealed a significant correlation except in the mid palatal area and the area 2 mm lateral to the mid-palate in men, whereas there was a significant relationship in every area in the women. In both men and women, the highest correlation appeared in the area 8 mm lateral to the mid palate. Conclusions: Using regression analysis, an actual prediction of the bone thickness between the measured bone thickness of the lateral cephalometric radiograph and 3D model was made. This will provide useful information for mini-implant length selection when inserting into the palate.

A Meta-Analysis of Korean Literatures about Sick Role Behavior of Pulmonary Tuberculosis Patients applied Health Belief Model (건강신념모형을 적용한 폐결핵 환자의 환자역할행태 연구에 대한 메타분석)

  • Kim, Chun-Bae;Jo, Heui-Sug;Rhee, Jung-Ae
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.1
    • /
    • pp.1-13
    • /
    • 2003
  • Objectives: The purpose of this study is to summarize results from 11 domestic studies about sick role behavior applied health belief model and to assess the effectiveness of components on behavior change by using meta-analysis. Methods: We collected the existing literatures by using major web search of 'pulmonary tuberculosis patients', 'health belief model', and 'sick role behavior' as key words and by reviewing content of journals. Quantitative meta-analysis was performed by SAS program. Results: Among 66 articles, 11 studies were selected for quantitative meta-analysis. The knowledge level about pulmonary tuberculosis had more effect for only sick role behavior as general characterisitcs(d=0.7870). All the components of health belief model produced significant effects on sick role behavior with the magnitude of effect size from 0.31 to 0.73. The largest effects were benefits on actions of sick role behavior. Conclusions: Overall, these investigation provide very substantial empirical evidence supporting health belief model dimensions as important contributors to the explanation and prediction of sick role behavior among the type of health related behavior in pulmonary tuberculosis patients. Strategic intervention including health education, etc. based on health belief model showed clear advantage in improvement of behavioral change.

  • PDF

Estimation of Wheat Growth using a Microwave Scatterometer (마이크로파 산란계를 이용한 밀 생육 추정)

  • Kim, Yihyun;Hong, Sukyoung;Lee, Kyungdo;Jang, Soyeong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.1
    • /
    • pp.23-31
    • /
    • 2013
  • Microwave remote sensing can help monitor the land surface water cycle and crop growth. This type of remote sensing has great potential over conventional remote sensing using the visible and infrared regions due to its all-weather day-and-night imaging capabilities. In this paper, a ground-based multi-frequency (L-, C-, and X-band) polarimetric scatterometer system capable of making observations every 10 min was developed. This system was used to monitor the wheat over an entire growth cycle. The polarimetric scatterometer components were installed inside an air-conditioned shelter to maintain constant temperature and humidity during the data acquisition period. Backscattering coefficients for the crop growing season were compared with biophysical measurements. Backscattering coefficients for all frequencies and polarizations increased until dat of year 137 and then decreased along with fresh weight, dry weight, plant height, and vegetation water content (VWC). The range of backscatter for X-band was lower than for L- and C-band. We examined the relationship between the backscattering coefficients of each band (frequency/polarization) and the various wheat growth parameters. The correlation between the different vegetation parameters and backscatter decreased with increasing frequency. L-band HH-polarization (L-HH) is best suited for the monitoring of fresh weight (r=0.98), dry weight (r=0.96), VWC (r=0.98), and plant height (r=0.96). The correlation coefficients were highest for L-band observations and lowest for X-band. Also, HH-polarization had the highest correlations among the polarization channels (HH, VV and HV). Based on the correlation analysis between backscattering coefficients in each band and wheat growth parameters, we developed prediction equations using the L-HH based on the observed relationships between L-HH and fresh weight, dry weight, VWC and plant height. The results of these analyses will be useful in determining the optimum microwave frequency and polarizations necessary for estimating vegetation parameters in the wheat.

The Prediction of the Origin of Microbial Contamination in Kimbab and Improvement of Microbiological Safety by Gamma Irradiation (김밥의 미생물 오염원 예측 및 미생물학적 안전성 개선을 위한 감마선 조사 효과)

  • Lee, Na-Young;Jo, Cheol-Hun;Chung, Hun-Jong;Kang, Ho-Jin;Kim, Jae-Kyung;Kim, Hyun-Ju;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.279-286
    • /
    • 2005
  • Microbial contamination origin of Kimbab was determined using nine types of ready-to-use ingredients, three each from animal, seafood, and vegetable sources. Effect of radiation on microbiological safety was also investigated. Total aerobic bacteria were not detected in seasoned beef, ham, and seasoned burdock, whereas 3.50, 5.41, 8.83, and 5.07 log CFU/g were detected in surimi gel, seasoned and blanched spinach, dried laver, and cucumber, respectively. Total aerobic bacterial and mold numbers were 8.73 and 5.08 log CFU/g in prepared Kimbab. Gamma irradiation reduced level of contaminated aerobic bacteria and mold population in Kimbab and its ingredients, Salmonella mutagenicity assay (Ames test) showed Kimbub ingredients irradiated at 10 kGy did not show any mutagenicity. These results indicate ready-to-use kimbab ingredients were mostly responsible for total aerobic bacteria and mold population of Kimbab, and low dose irradiation and low temperature storage ($10^{\circ}C$) effectively ensured microbiological safety of Kimbab and ready-to-use ingredients.