• 제목/요약/키워드: Precision Equipment

검색결과 839건 처리시간 0.029초

비전 시스템을 이용한 고속 고정도 자동 정렬장치 연구 (A Study on High Speed, High Precision Auto-alignment System Using Vision System)

  • 홍준희;전경한
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.457-460
    • /
    • 1998
  • Recently, the research of the FPD(Flat Panel Display)which is substituted for CRT(Cathode Ray Tube) has been widely progressed. But most equipment that are used for production of FPD are expensive and we must import these equipment. Among these equipment, most important one is a auto-alignment system. In this paper, we present a high speed, high precision auto-alignment system, in which a PLD auto tuning algorithm, 1-dimensional CCD(Dcharge Coupled Device) camera, vision board, and vision data processing algorithm are included.

  • PDF

마이크로 스테퍼를 활용한 역설계 시스템 구축 (The Construction of Reverse Engineering System Appling Micro Stepper)

  • 김수용;김민주;이승수;김순경;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.194-197
    • /
    • 2004
  • This paper is to develop of 3D reverse engineering equipment. The existing equipment didn't use in the field popularly as it is too expensive. So in this study, we build the reverse engineering system of simple construction using a LM guide and a laser sensor. Therefore we measured product using this equipment, this result compared with the CAD date.

  • PDF

기계장비의 구조 특성 예측 시뮬레이터 (Simulator of Accuracy Prediction for Developing Machine Structures)

  • 이찬홍;하태호;이재학;김양진
    • 한국정밀공학회지
    • /
    • 제28권3호
    • /
    • pp.265-274
    • /
    • 2011
  • This paper presents current state of the prediction simulator of structural characteristics of machinery equipment accuracy. Developed accuracy prediction simulator proceeds and estimates the structural analysis between the designer and simulator through the internet for convenience of designer. 3D CAD model which is input to the accuracy prediction simulator would simplified by the process of removing the small hole, fillet and chamfer. And the structural surface joints would be presented as the spring elements and damping elements for the structural analysis. The structural analysis of machinery equipment joints, containing rotary motion unit, linear motion unit, mounting device and bolted joint, are presented using Finite Element Method and their experiment. Finally, a general method is presented to tune the static stiffness at a rotation joint considering the whole machinery equipment system by interactive use of Finite Element Method and static load experiment.

Program Development for Vibration Performance Evaluation of Powder Transfer Equipment

  • Lee, Hyoung-Woo;Ryu, Jeong-Hyeon;Park, Noh-Gill
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.60-65
    • /
    • 2006
  • A vibrational model of powder transfer equipment based on the lumped parameter method was developed, in which the operating motion consists of surging, bouncing, and pitching. After decoupling the equation of motion, the vibrational excitation source of the pitching motion was removed. So the designers are able to plan the optimum design to adjust the motion trajectory of the powder transfer equipment. That is, a procedure to adjust the motion trajectory of powder transfer equipment by changing design specifications such as the installation position, the direction of the motor, the driving speed, the mass unbalance, the stiffness coefficient, and the installation position of the support spring, is presented in this paper. The powder transfer equipment manufactured according to the results of this study did not suffer fatigue destruction, since the maximum stress on the basket structure was sufficiently small.

Calculation of the Least Significant Change Value of Bone Densitometry Using a Dual-Energy X-ray Absorptiometry System

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.95-98
    • /
    • 2023
  • Purpose: The precision error of a bone density meter reflects the equipment and reproducibility of results by an examiner. Precision error values can be expressed as coefficient of variation (CV), CV%, and root mean square-SD (RMS-SD). The International Society for Clinical Densitometry (ISCD) currently recommends using RMS-SD as the precision error value. When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding the LSC value reflects a significant difference in measured bone density. Therefore, the LSC value of a bone density equipment is an essential factor for accurately determining a patient's bone density. Accordingly, we aimed to calculate the LSC value of a bone density meter (Lunar iDXA, GE) and compare it with the value recommended by the ISCD. We also assessed whether the value measured by the iDXA equipment was below the LSC value recommended by ISCD. Material and Methods: The bone densities of the lumbar spine and thighs of 30 participants were measured twice, and the LSC values were calculated using the precision calculation tool provided by the ISCD (http://www.iscd.org). To check the reproducibility of the measurement, patients were asked to completely dismount from the equipment after the first measurement; the patient was then repositioned before proceeding with the second measurement. Results: The LSC values derived using the CV% values recommended by the ISCD were 5.3% for the lumbar spine and 5.0% for the thigh. The LSC values measured using our bone density equipment were 2.47% for the lumbar spine and 1.61% for the thigh. The LSC value using RMS-SD was 0.031 g/cm2 for the lumbar spine and 0.017 g/cm2 for the thigh. Conclusion: that the findings confirm that the CV% value measured using our bone density meter and the LSC value using RMS-SD were maintained very stably. This can be helpful for obtaining accurate measurements during bone density follow-up examinations.

광정보저장용 광픽업 대물렌즈 성형용 코어 초정밀 형상가공 (I) (Ultra Precision Machining of Optical Pick-up Aspheric Glass Objective Lens Molding Press Core for Optical Information Storing (I))

  • 김민재;이준기;황연;김혜정;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.290-290
    • /
    • 2009
  • Blu-ray Disk, the next generation optical information storing equipment used Blu-ray is the next generation leading storing equipment that has capacity is about from six times to thirty-five times bigger than the existing CDs, DVDs. Especially, we need elaborate optical pick-Up equipment to record and recognize detailed date. Moreover, Blu-ray disk has so narrow track-pitch so it is used high NA(Numerical Aperture) aspheric glass objective lens. In this research, we processed optical pick-up aspheric glass objective lens molding press core by parallel grinding method with ultra precision machining and mold core surface measured form accuracy(PV), surface roughness(Ra).

  • PDF

볼과 소켓의 정밀 체결을 위한 회전성형 장치 (Rotary Forming Equipment for Precision Joining of the Ball and the Socket)

  • 전병윤;엄재근;전만수
    • 소성∙가공
    • /
    • 제16권2호
    • /
    • pp.132-137
    • /
    • 2007
  • A double roll rotary forming equipment is presented in this paper. The equipment is developed for joining the socket with the ball of a concave piston assembly with its geometrical tolerance requirements satisfied. The equipment is composed of a lathe, a double roll system and a roll pressing unit driven by the hydraulic system. The workpiece rotates by spindle chuck of the lathe while the double roll system approaches perpendicularly to the central line of the workpiece. The equipment is successfully applied to precision joining of the ball and the socket fur the concave piston assembly of a high pressure hydraulic pump.

5축 초음파 검사장비의 기구학 해석 (Kinematics Analysis of a 5-Axis Ultrasonic Inspection Equipment)

  • 한명철;성창민
    • 한국정밀공학회지
    • /
    • 제32권1호
    • /
    • pp.89-96
    • /
    • 2015
  • In this paper, it is studied that kinematic analysis of a 5-axis ultrasonic inspection equipment. The equipment is comprised of three straight axes and two rotary axes. With features of ultrasonic, the transmitter and receiver of the equipment are vertical to a test surface, operating at regular intervals. To perform this well, the motions of every link should be found on the based of kinematic analysis of the equipment. We chose starting point for testing and defined relations among all links through transformation of coordinates. For double curvature-shaped test object, we generated test paths. To follow these, we found motions of all links using inverse kinematics. By using Matlab/Simulink, simulator was developed, so that we could find out desired trajectories of main axes for a scan.

산업용 냉각탑의 진동소음이 정밀장비에 미치는 영향에 대한 연구 (An Investigation on Influence of Vibration Noise in Cooling Tower on Precision Equipments)

  • 이진갑
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.369-374
    • /
    • 2016
  • 냉각탑은 옥탑이나 건물 외부에 설치하여, 실내의 온도제어를 위해 사용된다. 냉각탑의 운전시 모터, 팬 및 낙하되는 냉각수에서 발생되는 소음 진동은 주변으로 전파가 용이하여, 인접한 건물 내부의 소음 진동 문제를 야기할 수 있다. 본 논문은 공장에 인접해 위치한 산업용 냉각탑의 진동 소음을 측정하여, 공장 내부의 정밀장비에 미치는 영향을 평가하였다. 정상 운전조건에서의 냉각탑의 소음을 측정하고, 냉각탑에서 일정거리 떨어진 공장의 바닥과 공장 내부에 위치한 정밀장비를 대상으로 진동을 측정하여, 냉각탑과 정밀기계의 진동 소음 평가기준에 의해 냉각탑의 진동 소음이 정밀장비의 정밀도에 미치는 영향을 분석하였다. 측정결과 냉각탑의 소음은 동일 용량 냉각탑의 기준 소음치인 68dB(A)보다 4~9dB(A) 높다. 냉각탑의 진동이 정밀장비에 미치는 영향은 냉각탑이 위치하는 건물 지지 프레임의 진동이 정밀장비가 위치한 바닥의 진동보다 낮아 영향은 미미하다. 정밀장비가 위치한 실내 바닥은 진폭은 허용기준치 안에 들어가나 진동 가속도 레벨 기준으로는 높게 나타났다.