• Title/Summary/Keyword: Precisely Measure

Search Result 279, Processing Time 0.028 seconds

Experimental Study for Evaluation of Non-Linear Dispersive Wave Model in Shallow Water (천해역 비선형분산파랑 모델의 평가를 위한 수리 실험 연구)

  • 이중우;신승호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.4
    • /
    • pp.189-196
    • /
    • 1999
  • In order to verify a numerical model for the calculation of wave motion around an offshore barrier in shallow water, laboratory physical experiments are necessary. In this study, sample experiments are carried out on the wave and wave induced current fields due to a sloping bottom topography and on that due to an isolated structure from the coastline. The water body is divided into 4 levels, in which the current tracking floaters are deployed to measure the wave induced currents. Data measurement was continued using the limited wave gauges and current tracking floaters including a video camera from the top. The wave heights for the preselected surface and time-averaged velocity distributions at each level were measured in detail. The distribution of wave and current fields was analyzed precisely combining the whole measured laboratory data. Moreover, comprehensive analyses were carried out on non-linearity of wave transformation in terms of skewness and atiltness.

  • PDF

ESTIMATION OF FATIGUE LIFE BY LETHARGY COEFFICIENT USING MOLECULAR DYNAMIC SIMULATION

  • Song, J.H.;Noh, H.G.;Yu, H.S.;Kang, H.Y.;Yang, S.M.
    • International Journal of Automotive Technology
    • /
    • v.5 no.3
    • /
    • pp.215-219
    • /
    • 2004
  • A vehicle structure needs to be more precisely analyzed because of complexities and varieties. Structural fatigue which is generated by fluctuations of stresses during the service life of a mechanical system is the primary concern in the structural design for safety. A fatigue life is difficult to obtain in structural components during the service life of mechanical systems since the fluctuating stress contributes to fatigue. This study introduces new procedures to measure the lethargy coefficient and to predict the fatigue life of a mechanical structure by using molecular dynamic simulation. A lethargy coefficient is the total defect-estimating coefficient, which was obtained by using the results of a simple tensile test in this study. With this lethargy coefficient, fatigue life was estimated. The proposed method will be useful in predicting the fatigue life of a structurally-modified vehicle design. The effectiveness of the proposed method using lethargy coefficient measurement to predict the fatigue life of a structure was examined by applying this method to predict the fatigue life of SS41 steel, used extensively as material of vehicle structures. Two types of specimen such as pre-cracked plate and simple plate is discussed. equation of fatigue life using the lethargy coefficient and failure time, both obtained from a simple tensile test, will be useful in engineering. This measurement and prediction technology will be extended for use in analysis of any geometric shapes of modified automotive structures.

Development of Concentration Control System for Ni-W Alloy Plating Solution (니켈-텅스텐 합금 도금 공정액 농도 제어 시스템 개발)

  • Kong, Jung-Shik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.273-279
    • /
    • 2016
  • This paper deals with a control system with a concentration sensor for Ni-W alloy plating solutions. The printed circuit board market has increased with the development of the electronics industry. Gold consumption has also increased dramatically. Various studies of composite plating solutions have been conducted because of the expense of gold. In comparison, the development of sensors capable of measuring a composite plating solution in real-time is still insufficient. Furthermore, there are few systems that can measure and control the concentration of the solution precisely. This study developed a sensor and system to control the concentration of composite plating solution accurately. The sensors were developed based on a spectrophotometric method and a feedback control method was applied in this system.

Radiotherapy Technique of High Energy Electron (고에너지 전자선의 방사선 치료 기술)

  • SUH M.W.;PARK J.I.;CHOI H.S.;KIM W.Y.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1985
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefore, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed does, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under $3\%$ errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under $5\%$ errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatters; i.e., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

On the Design of ToA Based RSS Compensation Scheme for Distance Measurement in WSNs (ToA 기반 RSS 보정 센서노드 거리 측정 방법)

  • Han, Hyeun-Jin;Kwon, Tae-Wook
    • The KIPS Transactions:PartC
    • /
    • v.16C no.5
    • /
    • pp.615-620
    • /
    • 2009
  • Nowadays, wireless infrastructures such as sensor networks are widely used in many different areas. In case of sensor networks, the wirelessly connected sensors can execute different kind of tasks in a diversity of environments, and one of the most important parameter for a successful execution of such tasks is the location information of each node. As to localization problems in WSNs, there are ToA (Timer of Arrival), RSS (Received Signal Strength), AoA (Angle of Arrival), etc. In this paper, we propose a modification of existing ToA and RSS based methods, adding a weighted average scheme to measure more precisely the distance between nodes. The comparison experiments with the traditional ToA method show that the average error value of proposed method is reduced by 0.1 cm in indoor environment ($5m{\times}7m$) and 0.6cm in outdoor environment ($10{\times}10m$).

Effects of Offspring-Related Characteristics on Depressive Disorder among Cancer Patients and Survivors

  • Kim, Jae-Hyun;Park, Eun-Cheol;Yeom, Hyungseon;Kwon, Jeoung A;Lee, Sang Gyu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4531-4536
    • /
    • 2015
  • Objective: To investigate the influence of offspring-related characteristics on the prevalence of depressive disorders among cancer patients and those who survived cancer for at least 45 years. Materials and Methods: Data were obtained from the Korean Longitudinal Study of Aging (KLoSA). To investigate the association between offspring and depressive disorder among cancer patients and survivors, we analyzed data from 292 cancer patients and survivors drawn from a total subject pool of 16,613 individuals at baseline. Results: According to our results, the odds ratio (OR) for subjects with five or more offspring developing depressive disorder was -0.794 (p-value: 0.039, SE: 0.329) compared with that of those with two offspring. In addition, the adjusted effect of the number of male and female offspring on the presence of depressive disorder showed that the OR for those with three or more female offspring for developing depressive disorder was -0.958 lower (SE: 0.305, p-value: 0.012) than it was for those with no female offspring. Conclusions: This article provides evidence for an association between offspring-related characteristics and depressive disorders among cancer patients and survivors. Therefore, offspring may be important contributors to the emotional status of cancer patients and survivors. Further study should precisely need to measure depressive disorders because of self-reported data.

Quantitative Measurement of Surfactant Protein B mRNA by Filter Hybridization (Filter Hybridization 방법에 의한 Surfactant Protein B mRNA의 정량측정)

  • Park, Sung-Soo;Lee, Dong-Hoo;Shin, Dong-Ho;Lee, Jung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.3
    • /
    • pp.242-247
    • /
    • 1992
  • Background: The ability to precisely measure specific mRNA levels by hybridization to complementary DNA probes is an important tool for analyzing the regulation of gene expression. Surfactant proteins have important roles in regulating surfactant metabolism as well as in determing its physical properties. Method: The complete coding regions for rat surfactant protein complementary DNA of surfactant protein B were subcloned into pGem 3Z or 4Z such that either antisense or sense transcripts were obtained by using SP 6 RNA polymerase. Surfactant protein B mRNA was measured by filter hybridization. Results: Equation of standard curve between counts per minute (Y) and surfactant protein B mRNA transcript input (X) was Y=2034.9 X+159.1. Correlation coefficient was 1.0. Couclusions: Filter hybridization assay is suited to situation when rapid, accurate quantitation of multiple samples is required.

  • PDF

Capacitive Voltage Divide for a Pulsed High-Voltage Measurement (펄스형 고전압 측정용 용량성 분압기)

  • Jang Sung-Duck;Son Yoon-Kyoo;Kwon Sei-Jin;Oh Jong-Seok;Cho Moo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.63-68
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source are under operation for 2.5 GeV electron linear accelerator in Pohang Light Source (PLS) linac. The klystron-modulator system has an important role for the stable operation to improve an availability statistics of overall system performance of klystron-modulator system. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are demanded for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider (CVD), which divides input voltage as capacitance ratio, is intended for the measurement of a beam voltage of 400 kV generated from the klystron-modulator system. Main parameter to determine standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will be present and discuss the design concept and analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance effects and oil temperature variation.

Studies on Dose Distribution and Treatment Technique of High Energy Electron (고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究))

  • Lee, D.H.;Chu, S.S.
    • Journal of Radiation Protection and Research
    • /
    • v.3 no.1
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Measurement of thermal conductivity of fluid by unsteady hot wire method (非定常 熱線法 에 의한 流體 의 熱傳達率 測定)

  • 고상근;양상식;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.154-161
    • /
    • 1984
  • A modified technique of the transient hot wire method to measure the thermal conductivity of fluid has been described in this paper. The thermal conductivity of fluid can be obtained by acquiring wire temperature as a function of time. Multiplication of the inverse slope of the temperature versus logarithm of time by an instrumental constant gives the thermal conductivity. The constant voltage was applied to Wheatstone bridge circuit. The wire temperature can be measured as a function of time precisely with the aid of the data acquisition system composed of a microprocessor and an analog-digital converter. The thermal conductivity of the electrically conducting fluid has been measured with the insulated hot wire coated by electrically non-conducting material. The effect of the coated insulation layer on the thermal conductivity has been examined, in which it is confirmed that the thermal conductivity of electrically conducting liquid can be determined by the transient coated hot wire method. Thermal conductivities of methanol, carbontetrachrolide, Freon-22 and glycerin have been measured at room temperature in the pressure from 0.1MPa to 35.1MPa. The experiment has been performed to compare the data from the bare and the coated wires, and the results are satisfactory.