• Title/Summary/Keyword: Precise Diagnosis

Search Result 396, Processing Time 0.028 seconds

A study on the 3-D positional analysis for track of magnetically levitated vehicles (자기부상열차 선로의 3차원 위치해석에 관한 연구)

  • 강준묵;윤희천;배상호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.2
    • /
    • pp.229-236
    • /
    • 1995
  • This study is the 3-D positional analysis for track of magnetically levitated vehicles to precise construction and periodical safe diagnosis by photogrammetry. In the result, we could improve the accuracy of Z as well as X, Y using the modified control points of spatial distribution to the plane distribution of the absolutly effective control points to accuracy and diagnosis the the track of magnetically levitated vehicles using the below 1㎜ accuracy. And we could analysis the 3-D precise positions and efficiently decide the geometric characteristics of the cant and gradient to the instrument.

  • PDF

A Development of the High Precise Measuring Device and Methods of Resistive Leakage Current for the Deterioration Diagnosis of ZnO Arrester (산화아연 피뢰기의 열화진단을 위한 저항성누설전류의 고정도 측정기법 및 장치의 개발)

  • Lee, B.H.;Kang, S.M.;Jeon, D.K.;Park, K.Y.;Choi, H.S.;Cho, S.C.;Baek, Y.H.;Lee, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1668-1670
    • /
    • 2003
  • This paper deals with a development of the high precise measuring device of resistive leakage current for the deterioration and diagnosis of ZnO arresters. The resistive leakage current increasing with time leads to a thermally unstable state that may even experience a disaster. So, the resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with an analysis program operated with micro-processor using the time delay addition method was designed and fabricated. The proposed measuring systems for the resistive leakage current can effectively be used to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.⨀ᔌ?؀㔳㤮㈻Ԁ䭃䑎䷗ᜒं6〰Ԁ䭃䑎䴀

  • PDF

The Application of IRR-Camera for the Diagnosis of Surface Degradation (표면열화진단을 위한 적외선카메라의 응용)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.61-65
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

Development of Preventive Diagnosis Techniques for Transformer Oil by Capacitive Sensor (전기용량형 센서를 이용한 변압기 절연유 열화진단용 예방진단기법 개발)

  • Kim, Ju-Han;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2061_2062
    • /
    • 2009
  • Within serviced period of time in transformer, thermal stress is the most influential parameter affecting the aging behavior of an insulation system. The thermal stress on the insulation system may occur from operation in a high temperature environment due to Joule's heat at winding coils. This paper describes a development of capacitive sensor and preventive diagnosis techniques for electrical insulating oil, widely used for power and distribution transformer. To survey the dielectric properties of the virgin and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate diagnosis by the sensor, we performed accelerated aging test about insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor.

  • PDF

A Study on the Noise Diagnosis and Suppression of the Temperature Sensor in the LCD Plant (LCD공장 내부의 온도센서 노이즈진단 및 억제에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bum;Hwang, Young-Rok;Kim, Yong-Kwan;You, Chang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.35-41
    • /
    • 2012
  • As automation equipment and electronic device progresses, the importance of power quality is more increasing. This paper represents the analysis and suppression about the causes of trouble by the inverter's ON/OFF noise in plant in order to prevent damage resulting in a secondary damage to conduct precise diagnosis and effective noise reduction. The countermeasure as a reduced carrier frequency and the LC resonant filter had been applied and confirmed the effective results to solve the trouble of noise.

Development of Phase Sensitive Detector for Diagnosis of Distribution Transformers (배전용 변압기의 진단을 위한 위상 검출 장치의 개발)

  • Kim, Young-Chun;Choi, Do-Hyuk;Yoon, Yong-Han;Min, Kyeoung-Rae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.547-549
    • /
    • 2000
  • This paper develops phase sensitive detector for diagnosis of distribution transformers. And to detect the $tan{\delta}$ more effectively, this paper used phase sensitive detector. The sensor in oil which could be placed inside of the distribution transformer can measures the $tan{\delta}$ in oil. This could be the important factor and information, and it could be used for the basic information for a precise diagnosis. Establishment of the proposed system helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

The New Aging Diagnosis in IEC-60587 (IEC-60587의 새로운 열화진단)

  • Lim, Jang-Seob;Chung, Seung-Chun;Jeong, Jong-Cheol;Park, Gye-Choon;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.71-74
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used In surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

Development of 64-Channel 12-bit 1ks/s Hardware for MCG Signal Acquisition (심자도 신호 획득을 위한 실시간 64-Ch 12-bit 1ks/s 하드웨어 개발)

  • Lee, Dong-Ha;Yoo, Jae-Tack
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.902-905
    • /
    • 2004
  • A heart diagnosis system adopts Superconducting Quantum Interface Device(SQUID) sensors for precision MCG signal acquisitions. Such system is composed of hundreds of sensors, requiring fast signal sampling and precise analog-digital conversions(ADC). Our development of hardware board, processing 64-channel 12-bit 1ks/s, is built by using 8-channel ADC chips, 8-bit microprocessors, SPI interfaces, and parallel data transfers between microprocessors to meet the 1ks/s, i.e. 1 ms speed. The test result shows that the signal acquisition is done in 168 usuc which is much shorter than the required 1 ms period. This hardware will be extended to 256 channel data acquisition to be used for the diagnosis system.

  • PDF

A Study on the Fault Diagnosis in Web-based Virtual Machine (웹기반 가상시계에서의 고장진단에 관한 연구)

  • 서정완;강무진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.430-434
    • /
    • 2001
  • Virtual manufacturing system is integrated computer model that represents the precise and whole structure of manufacturing system and simulates its physical and logical behavior in operation.[1] A virtual machine is computer model that represents a CNC machine tool and one of core elements of virtual manufacturing system. In this paper, it is emphasized that a virtual machine must be web-based system for serving information to all attendants in a real machine tool without the restriction of time or location, and then in the fault diagnosis, one of important modules of a virtual machine, the methods of both using the controller signal and web-based expert system are proposed.

  • PDF

Commentary on the new 2022 European Society of Human Reproduction and Embryology (ESHRE) endometriosis guidelines

  • Eun Hee Yu;Jong Kil Joo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.4
    • /
    • pp.219-224
    • /
    • 2022
  • Endometriosis is a prevalent benign illness defined by the presence of endometrial glands and stroma outside of the uterine cavity, primarily on the ovary, pelvic peritoneum, and rectovaginal septum, resulting in a variety of symptoms, including dysmenorrhea and infertility. Traditionally, prolonged medical therapy has been needed in most cases since a conservative approach to surgery has usually been taken, especially in young women. In 2022, new European Society of Human Reproduction and Embryology (ESHRE) guidelines were published that present different directions for diagnosis and treatment from the past. Furthermore, the guidelines for the diagnosis and management of endometriosis are more precise and applicable than in previous editions. Thus, referring to the representative changes in the new guidelines and important updates will be beneficial for the diagnosis and management of endometriosis. This paper provides a brief overview of these developments.