• Title/Summary/Keyword: Precipitation Separation

Search Result 179, Processing Time 0.024 seconds

Estimation of Groundwater Recharge from Precipitation in a Small Basin (소유역의 강수에 의한 지하수 함양량 산정)

  • Bae, Sang-Keun;Lee, Seung-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.5
    • /
    • pp.397-406
    • /
    • 2004
  • It is necessary to estimate the groundwater recharge rate properly to evaluate the reasonable development amount of groundwater in a specific site. A small basin in Wicheon River Basin located in the Province of Kyungsangbuk-Do is selected to calculate the groundwater recharge rate. Average annual groundwater recharge rates are calculated from 1992 to 1997 because wet and draught year are contained during this period. In the calculation, baseflow separation method and SCS-CN method are applied to this area. As a result of estimation by baseflow separation method, the value of groundwater recharge ratio is varied between 11.9% and 18.7%. The average annual recharge rate is 14.5%. The average annual recharge rate calculated by SCS-CN method is varied between 7.9% and 20.9%. The average annual recharge rate in the calculation period is 15.1%. The results show that the average annual recharge amount from infiltration in the study basin is 141.6mm and 147.4mm in each estimation method. It appears that the average annual recharge amount calculated for the long period containing wet and draught year by the two methods is useful for groundwater development.

Purification of wastewater from paper factory by cryo-cooled high-$T_c$ superconducting magnetic separator (전도냉각형 고온초전도 자석을 이용한 제지폐수의 자기분리에 의한 정수)

  • Ha, Dong-Woo;Kim, Tae-Hyung;Sohn, Myung-Hwan;Kwon, Jun-Mo;Baik, Seung-Kyu;Oh, Sang-Soo;Ko, Rock-Kil;Ha, Hong-Soo;Kim, Ho-Sup;Kim, Young-Hun;Kang, Che-Hun;Ha, Tae-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.4-4
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purify rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

Oil/Water Separation Technology by MXene Composite Membrane: A Review (MXene 복합막에 의한 기름/물 분리 기술: 총설)

  • Lee, Byunghee;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.304-314
    • /
    • 2021
  • Climate change results in unusual weather pattern and affects annual rain fall severely. At the same time, growing industrialization leads to higher energy demand and leakage from petrochemical industry and tanker leads to water pollution. In this scenario, finding out solution to generate clean water is highly essential. For oil/water separation, there are several methods available such as chemical precipitation and adsorption but membrane separation technique is considered to be a more cost and energy efficient process. Amphiphilicity nature of membrane are enhanced by making composite membrane with 2D material such as MXene, resulting in good electrical conductivity and hydrophilicity. This review is mainly classified into two sections: pure MXene and modified MXene. A variety of polymer is used to prepare composite membranes and MXene is modified to further enhance the properties suitable for particular applications.

Analytical method for determination of 41Ca in radioactive concrete

  • Lee, Yong-Jin;Lim, Jong-Myoung;Lee, Jin-Hong;Hong, Sang-Bum;Kim, Hyuncheol
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1210-1217
    • /
    • 2021
  • The analysis of 41Ca in concrete generated from the nuclear facilities decommissioning is critical for ensuring the safe management of radioactive waste. An analytical method for the determination of 41Ca in concrete is described. 41Ca is a neutron-activated long radionuclide, and hence, for accurate analysis, it is necessary to completely extract Ca from the concrete sample where it exists as the predominant element. The decomposition methods employed were the acid leaching, microwave digestion, and alkali fusion. A comparison of the results indicated that the alkali fusion is the most suitable way for the separation of Ca from the concrete sample. Several processes of hydroxide and carbonate precipitation were employed to separate 41Ca from interferences. The method relies on the differences in the solubility of the generated products. The behavior of Ca and the interfering elements such as Fe, Ni, Co, Eu, Ba, and Sr is examined at each separation step. The purified 41Ca was measured by a liquid scintillation counter, and the quench curve and counting efficiency were determined by using a certified reference material of known 41Ca activity. The recoveries in this study ranged from 56 to 68%, and the minimum detectable activity was 50 mBq g-1 with 0.5 g of concrete sample.

Conditions of Hemoglobin Hydrolysis and Separation for the Production of Enriched Heme-iron (고농도 Heme-iron의 생산을 위한 Hemoglobin의 가수분해 및 분리 조건)

  • Kang, In-Kyu;In, Man-Jin;Oh, Nam-Soon
    • Applied Biological Chemistry
    • /
    • v.44 no.4
    • /
    • pp.219-223
    • /
    • 2001
  • Effects of hemoglobin (Hgb) concentration and degree of hydrolysis (DH) of Hgb on the separation of heme-iron were examined to produce highly enriched heme-iron from Hgb hydrolysate. Separation efficiency of Hgb hydrolysate with different DH was studied at wide pH range (pH $1.0{\sim}11.0$). Separation efficiency expressed as heme-iron/peptide ratio increased with decreasing Hgb concentration. When 5% Hgb (pH 10.0) was hydrolyzed using commercially available Esperase for 5 h at $50^{\circ}C$, DH was 25%. The precipitation of heme-iron-enriched peptides were remarkably high at pH range $3{\sim}6$. Optimal pH range for heme-iron with high heme-iron/peptide ratio shifted to acidic pH with increasing DHs of Hgb. The enriched heme-iron fraction in the precipitates showed a single band through urea-SDS-PAGE, with a molecular mass of 1 kDa. In the dry heme-iron product produced in a pilot bioreactor, content of heme-iron and heme-iron/peptide ratio were 27.1 and 38.7%, respectively, and production yield was 9.3%.

  • PDF

Influences of Fractionation of Stable Isotopic Composition of Rain and Snowmelt on Isotopic Hydrograph Separation (강우와 융설의 안정동위원소 변동에 의한 동위원소 수문분리법의 계통오차계산)

  • Lee, Jeonghoon;Koh, Dong-Chan;Choo, Mi Kyung
    • Journal of the Korean earth science society
    • /
    • v.35 no.2
    • /
    • pp.97-103
    • /
    • 2014
  • An isotopic hydrograph separation technique has been able to determine the contribution of new water (event water such as rain or snowmelt) and old water (pre-event water like groundwater) to a stream hydrograph for last several decades using stable water isotopes. It is based on the assumption that the isotopic compositions of both new water and old water at a given instant in time are known and the stream water is a mixture of the two waters. In this study, we show that there is a systematic error (standard error in the new water fraction) in the isotopic hydrograph separation if the average isotopic compositions of new water were used ignoring the temporal variations of those of new water. The standard error in the new water fraction is caused by: (1) the isotopic difference between the average value and temporal variations of new water; (2) the new water fraction as runoff contributing to the stream during rainfall or spring melt; and (3) the isotopic differences between new and old water (inversely). The standard error is large, in particular, when new water dominates the stream flow, such as runoff during intense rainfall and in areas of low infiltration during spring melt. To reduce the error in the isotopic hydrograph separation, incorporation of fractionation in the isotopic composition of new water observed at a point should be considered with simultaneous sampling of new water, old water and stream water.

Hydrograph Separation and Flow Characteristic Analysis for Observed Rainfall Events during Flood Season in a Forested Headwater Stream (산지계류에 있어서 홍수기의 강우사상에 대한 유출수문곡선 분리 및 특성 분석)

  • Nam, Sooyoun;Chun, Kun-Woo;Lee, Jae Uk;Kang, Won Seok;Jang, Su-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.1
    • /
    • pp.49-60
    • /
    • 2021
  • We examined the flow characteristics by direct runoff and base flow in a headwater stream during observed 59 rainfall events of flood season (June~September) from 2017 to 2020 yrs. Total precipitation ranged from 5.0 to 400.8 mm, total runoff ranged from 0.1 to 176.5 mm, and runoff ratio ranged from 0.1 to 242.9% during the rainfall events. From hydrograph separation, flow duration in base flow (139.3 days) was tended to be longer than direct runoff (78.3 days), while the contribution of direct runoff in total runoff (54.2%) was greater than base flow (45.8%). The total amount and peak flow of direct runoff and base flow had the highest correlation (p<0.05) with total precipitation and duration of rain among rainfall and soil moisture conditions. Dominant rainfall events for the total amount and peak flow of base flow were generated under 5.0~200.4 and 10.5~110.5 mm in total precipitation. However, when direct runoff occurred as dominant rainfall events, total amount and peak flow were increased by 267.4~400.8 and 169.0~400.8 mm in total precipitation. Therefore, the unique aspects of our study design permitted us to draw inferences about flow characteristic analysis with the contribution of base flow and/or direct runoff in the total runoff in a headwater stream. Furthermore, it will be useful for the long-term strategy of effective water management for integrated surface-groundwater in the forested headwater stream.

Microencapsulation Methods for Delivery of Protein Drugs

  • Yoon Yeo;Namjin Baek;Park, Kinam
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.4
    • /
    • pp.212-230
    • /
    • 2001
  • Recent advances in recombinant DNA technology have resulted in development of many new protein drugs. Due to the unique properties of protein druges, they have to be delivered by parenteral injection Although delivery of protein drugs by other routes, such as pulmonary and nasal routes, has shown some promises, to date most protein drugs are administered by par-enteral routs. For long-term delivery of protein drugs by parenteral administration, they have been formulated into biodegradable microspheres. A number of microencapsulation methods have been developed, and the currently used microencapsulation methods are reviewed here, The microen-capsulation methods have been divided based on the method used. They are: solvent evapora-tion/extraction; phase separation (coacervation);spray drying; ionotropic gelation/polyelectrolyte complexation; interfacial polyumerization and supercritical fluid precipitation. Each method is de-scribed fro its applications, advantages, and limitations.

  • PDF

The Determination of Gold in Assay Process by Thermal Neutron Activation Analysis (試金工程中의 金의 熱中性子에 依한 放射化分析)

  • J.I. Kim;Chong Kuk Kim;W.P. Chang
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.165-169
    • /
    • 1963
  • 12 samples from an assay process chain were submitted to qualitative and quantitative neutron activation analysis for the determination of gold. Gold was detected and quantitatively determined in three samples after a chemical separation consisting of solvent extraction and precipitation steps. Recoveries ranged between 81.0 and 93.6% and results of duplicated determinations were reproducible. Quantitative data were obtained from gamma-spectrometric photopeak-area counting. Interference from fast neutron reactions was negligible.

  • PDF

The Removal of Arsenic from Contaminated Water using a Hybrid Membrane Process.

  • Legault, A.S.;Trembaly, A.Y.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.93-104
    • /
    • 1997
  • The objective of this study is to develop a method to reduce arsenic concentrations in contaminated water. This work is also aimed at increasing the specificity of membrane separation processes. Arsenic in contaminated waters is often present in the form of negatively charged oxyanions. These are relatively small molecules which cannot be separated directly by ultrafiltration. Oxyanions can be captured by polyelectrolytes and separated by ultrafiltration. Results will be presented on the use of two polyelectrolytes; polyethylenimine (PEI) and poly-diallyl dimethyl ammonium chloride (DADMAC) at various feed concentrations. A semi-continuous process utilizing PEI in a circulation loop was tested. The restfits indicate that better than 99.6 % recovery (permeate concentration < 0.001 $\mu$g/L) can be achieved based on an initial arsenic concentration of 300 $\mu$g/L. The results indicate that this treatment method is suitable as a main treatment process for drinking water or a polishing step after arsenic precipitation.

  • PDF