Usefulness and clinical availability for surgery efficiency were evaluated by conducting pre-operative planning with a model manufactured by desktop 3D printer by using clavicle CT image. The patient-customized clavicle fracture model was manufactured by desktop 3D printer of FDM wire laminated processing method by converting the CT image into STL file in Open Source DICOM Viewer Osirix. Also, the model of the original shape before damaged was restored and manufactured by Mirror technique based on STL file of not fractured clavicle of the other side by using the symmetry feature of the human body. For the model, the position and size, degree of the fracture was equally printed out. Using the clavicle model directly manufactured with low cost and less time in Department of Radiology is considered to be useful because it can reduce secondary damage during surgery and increase surgery efficiency with Minimal invasive percutaneous plate osteosynthesis(MIPO).
Computer-aided surgery (CAS) started being used for head and neck reconstruction in the late 2000s. Its use represented a paradigm shift, changing the concept of head and neck reconstruction as well as mandible reconstruction. Reconstruction using CAS proceeds through 4 phases: planning, modeling, surgery, and evaluation. Thus, it can overcome a number of trial-and-error issues which may occur in the operative field and reduce surgical time. However, if it is used for oncologic surgery, it is difficult to evaluate tumor margins during tumor surgery, thereby restricting pre-surgical planning. Therefore, it is dangerous to predetermine the resection margins during the presurgical phase and the variability of the resection margins must be taken into consideration. However, it allows for the preparation of a prebending plate and planning of an osteotomy site before an operation, which are of great help. If the current problems are resolved, its applications can be greatly extended.
Kim, Yoon-Hyuk;Phong, Le Dinh;Kim, Kyung-Soo;Kim, Tae-Seong
Journal of Biomedical Engineering Research
/
v.29
no.6
/
pp.431-435
/
2008
Quantitative information of a three dimensional(3D) kinematics of joint is very useful in knee joint surgery, understanding how knee kinematics related to joint injury, impairment, surgical treatment, and rehabilitation. In this paper, an automated 2D/3D image matching technique was developed to estimate the 3D in vivo knee kinematics using dual X-ray images. First, a 3D geometric model of the knee was reconstructed from CT scan data. The 3D in vivo position and orientation of femoral and tibial components of the knee joint could be estimated by minimizing the pixel by pixel difference between the projection images from the developed 3D model and the given X-ray images. The accuracy of the developed technique was validated by an experiment with a cubic phantom. The present 2D/3D image matching technique for the estimation of in vivo joint kinematics could be useful for pre-operative planning as well as post-operative evaluation of knee surgery.
Chung Goo Bong;Kim Sungmin;Lee Soo Gang;Yi Byung-Ju;Kim Wheekuk;Oh Se Min;Kim Young Soo;So Byung Rok;Park Jong Il;Oh Seong Hoon
International Journal of Control, Automation, and Systems
/
v.4
no.1
/
pp.30-41
/
2006
The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods for spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Some experiments employing the developed robotic surgery system are conducted. The experimental results confirm that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to respiration.
Proceedings of the Korean Society of Precision Engineering Conference
/
2005.10a
/
pp.144-148
/
2005
The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods fer spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images and intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Several experiments employing the developed robotic surgery system are conducted. The experimental results confirmed that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to his/her respiration.
Recently in treatment planning for orthognathic surgery, 3-dimensional analysis using CBCT can give more detailed information that cannot be achieved with 2-dimensional cephalograms. Also, laser Scanning and 3D camera can show 3-dimensional information on soft tissue changes as well as hard tissue changes in orthognathic surgery patients. In other words, soft tissue changes in lateral facial area as well as mid facial area can be quantitatively calculated. To bring out the best results from orthognathic surgery, close interaction between orthodontist and oral surgeon is needed and well treated pre-surgical orthodontics can simplify orthognathic surgical plan that also results in good long-term stability. In surgery-first cases, more thoughtful diagnosis and pre-operative preparation will be needed to prevent complicated problems.
Background: FDG PET/CT is at an equivocal stage to recommend for staging of colorectal cancer as compared to contrast-enhanced CT (ceCT). This study was intended to evaluate the value of FDG PET/ceCT in colorectal cancer staging as compared to ceCT alone. Materials and Methods: PET/ceCT was performed for 61 colorectal cancer patients who were prospectively enrolled in the study. Three patients were excluded due to loss to follow-up. PET/ceCT findings and ceCT results alone were read separately. The treatment planning was then determined by tumor board consensus. The criteria for T staging were determined by the findings of ceCT. Nodal positive by PET/ceCT imaging was determined by visual analysis of FDG uptake greater than regional background blood pool activity. The diagnostic accuracy of T and N staging was determined only in patients who received surgery without any neoadjuvant treatment. Results: Of 58 patients, there were 40 with colon cancers including sigmoid cancers and 18 with rectal cancers. PET/ceCT in pre-operative staging detected bone metastasis and metastatic inguinal lymph nodes (M1a) that were undepicted on CT in 2 patients (3%), clearly defined 19 equivocal lesions on ceCT in 18 patients (31%) and excluded 6 metastatic lesions diagnosed by ceCT in 6 patients (10%). These resulted in alteration of management plan in 15 out of the 58 cases (26%) i.e. changing from chemotherapy to surgery (4), changing extent of surgery (9) and avoidance of futile surgery (2). Forty four patients underwent surgery within 45 days after PET/CT. The diagnostic accuracy for N staging with PET/ceCT and ceCT alone was 66% and 48% with false positive rates of 24% (6/25) and 76% (19/25) and false negative rates of 47% (9/19) and 21% (4/19), respectively. All of the false negative lymph nodes from PET/ceCT were less than a centimeter in size and located in peri-lesional regions. The diagnostic accuracy for T staging was 82%. The sensitivity of the peri-lesional fat stranding sign in determining T3 stage was 94% and the specificity was 54%. Conclusions: Our study suggested promising roles of PET/ceCT in initial staging of colorectal cancer with better diagnostic accuracy facilitating management planning.
Considering the skeletal class III malocclusion that complains of mandibular prognathism, there have been some studies of the mandibular change for comparing the changes of pre operative with post operative state. Nowadays it is common to do the orthognathic 2-jaw surgery for the correction of the maxillary deficiency, the post operative stability and the esthetics. We compare and analyze the changes of soft tissue around the nose and the lip with the changes in the direction and the amount of maxilla. Patients who were diagnosed as maxillofacial deformity and received orthognathic surgery of both jaws at Yongdong Severance hospital from 2001 through 2003 were included in this study. Their lateral cephalograms were analyzed, and the post operative change of hard tissue and soft tissue were studied. Upon analyzing the preoperative cephalograms and 6 month post operative cephalograms, there were significant in the vertical change of Labialis superius(Ls) and Stomion(Stm) in soft tissue in relation to the vertical change of skeletal landmarks (Anterior Nasal Spine, Subspinale, Prosthion, Incision Superious). In addition, there were no significance in horizontal movement of the skeletal landmarks among groups. In terms of hard tissue landmarks, group 3(maxillary posterior impaction and advancement surgery group) showed significantly greater change in the vertical movement of Anterior Nasal Spine(ANS), Subspinale(A), Prosthion(Pr), and Incision Superious(Is) compared with other groups. In terms of soft tissue change, group 3 showed more significant change in the vertical movement of Ls and Stm. This study calculated the changes of the skeletal and soft tissue landmarks in order to act as a guide in planning and performing the surgery and as a reference in predicting the postoperative change of facial appearance.
Nam, Woong;Makhoul, Nicholas;Ward, Brent;Helman, Joseph I.;Edwards, Sean
Maxillofacial Plastic and Reconstructive Surgery
/
v.34
no.5
/
pp.337-342
/
2012
The osseous or osteocutaneous free fibula flap has become the gold standard for most mandibular reconstructions because of its favorable osseous characteristics. However, disadvantages, such as the time-consuming reconstructive step, difficulty in performing the osteotomies to precisely recreate the shape of the missing segment of mandible and poor bone-to-bone contact play a role in making the surgeons look for alternative flaps. With the advent of computerized design software, which accurately plans complex 3-dimensional reconstructions, has become a process that is more efficient and precise. However, the ability to transfer the computerized plan into the surgical field with stereolithographic models and guides has been a significant development in advancing reconstruction in the maxillofacial regions. The ability to "pre-plan" the case, mirror and superimpose natural structures into diseased and deformed areas, as well as the ability to reproduce these plans with good surgical precision has decreased overall operative time, and has helped facilitate functional and esthetic reconstruction. We describe a complex case treated with this technique, showing the power and elegance of computer assisted maxillofacial reconstruction from the University of Michigan, Oral and Maxillofacial Surgery.
Objective: Condylar resorption (CR) is one of the major post-surgical complications of orthognathic surgery. This systematic review (SR) aimed to evaluate epidemiological data, risk factors, and therapeutical management of CR. Methods: Six databases were screened by two investigators until September 2020 to obtain all SRs. After reading the titles and abstracts, eligible SRs were determined and data extraction was performed. Using the latest version of A Measurement Tool to Assess Systematic Reviews, the methodological quality of the included SRs was determined. Results: Ten SRs with low or critically-low methodological quality were included in this review. Mandibular hypoplasia on the sagittal plane and hyperdivergent growth pattern on the vertical plane were the most common skeletal alterations in which CR could occur after orthognathic surgery. Post-operative condylar changes were analyzed both on two-dimensional and three-dimensional (3D) radiographic examinations. The incidence of CR was not related to the fixation method. Based on the severity of the pathological conditions, management of CR can include conservative or surgical therapy. Conclusions: Despite the limited evidence in literature, CR is considered a consequence of orthognathic surgery. However, an accurate diagnosis of CR and a better orthognathic surgical planning must include 3D radiographic examinations to improve pre- and post-surgical comparison. Well-designed studies with long-term follow-up and 3D data are needed to clarify the findings of this analysis..
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.