• 제목/요약/키워드: Pre-loading reverse torque value

검색결과 2건 처리시간 0.017초

The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload

  • Altuwaijri, Shahad Mohammmed;Alotaibi, Hanan Nejer;Alnassar, Talal Mughaileth
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.22-31
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate the misfit and screw preload at the implant abutment connection of implant supported fixed dental prosthesis with cantilever (ICFDP) manufactured using different digital manufacturing techniques and to compare the screw preload before and after cyclic loading. MATERIALS AND METHODS. Mandibular jaw model with four intra-foraminal implants was scanned using digital scanner. Stereolithography file was used to design a framework with nonengaging (NE) abutments and 10 mm cantilever distal to one terminal implant. Five frameworks were constructed using combined digital-conventional techniques (CAD-cast), and five frameworks were constructed using three-dimensional printing (3DP). Additional CAD-cast framework was constructed in a way that ensures passive fit (PF) to use as control. Scanning electron microscope (SEM) measured the implant abutment connection misfit. Sixty screws were used on the corresponding frameworks. Screws were torqued and pre-cyclic loading reverse torque value (RTV) was recorded. Frameworks were subjected to 200,000 loading cycles with a loading point 9 mm from the center of terminal implants adjacent to the cantilever and post-cyclic loading RTVs were recorded. RESULTS. Microscopic readings showed significant differences between frameworks. PF demonstrated the lowest measurements of 16.04 (2.6) ㎛ while CAD-cast demonstrated the highest measurements of 29.2 (3.1) ㎛. In all groups, RTVs were significantly lower than the applied torque. Post-cyclic loading RTV was significantly lower than pre-cyclic loading RTV in PF and 3DP frameworks. Differences in RTVs between the three manufacturing techniques were insignificant. CONCLUSION. Although CAD-cast and three-dimensionally printed (3DP) both produce frameworks with clinically acceptable misfit, 3DP might not be the technique of choice for maintaining screw's preload stability under an aggressive loading situation.

기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교 (A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment)

  • 김종욱;허유리;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.276-283
    • /
    • 2013
  • 연구 목적: 본 연구에서는 기성 지대주와 맞춤형CAD-CAM 지대주의 적합성 및 나사 사이의 안정성 대해 알아보고자 한다. 연구 재료 및 방법: 오스템 임플란트 시스템을 이용하였다. 동일회사에서 제작된 기성 지대주(Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea) 및 맞춤형CAD-CAM 지대주(CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea)와 국내 외주 제작된 맞춤형CAD-CAM 지대주(Myplant, Raphabio Co., Seoul, Korea)를 5개씩 선택, 제작하였으며 나사는 각 회사에서 제공되는 것을 사용하였다. 제조사의 지시에 따라 고정체와 지대주를 30 Ncm으로 조인 후 초기 풀림 토크를 3회 반복 측정한 후 통계 분석하였다(${\alpha}=.05$). 고정체-지대주 연결체를 에폭시 레진에 매몰 후 습식 절삭 및 연마하여 계면 사이의 적합성을 FE-SEM으로 관찰하였다. 결과: 지대주의 초기 풀림 토크 값은 각각 기성 지대주(Transfer abutment)에서 $26.0{\pm}0.30Ncm$, 동일 회사에서 제작된 맞춤형CAD-CAM 지대주(CustomFit abutment)에서 $26.3{\pm}0.32Ncm$, 외주로 제작된 맞춤형CAD-CAM 지대주(Myplant abutment)에서 $24.7{\pm}0.67Ncm$였다. 국내 외주 제작된 맞춤형CAD-CAM 지대주에서 유의적으로 낮은 초기 풀림 토크 값을 보였으며(P=.027), 고정체-지대주 계면에서 변연 간극이 관찰되었다. 결론: 본 실험의 한계 내에서 국내 외주 제작된 맞춤형CAD-CAM 지대주는 동일 회사에서 제작된 기성 지대주나 맞춤형CAD-CAM 지대주에 비해 더 낮은 나사 안정성 및 적합성을 보인다고 볼 수 있다.