• 제목/요약/키워드: Pre-engineered metal building

검색결과 5건 처리시간 0.019초

Ultimate strength of long-span buildings with P.E.B (Pre-Engineered Building) system

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1483-1499
    • /
    • 2015
  • With the improvement of the quality of construction materials and the development of construction technologies, large-scale long-span steel frame buildings have been built recently. The P.E.B system using tapered members is being employed as an economically-efficient long-span structure owing to its advantage of being able to distribute stress appropriately depending on the size of sectional areas of members. However, in December 2005 and in February 2014, P.E.B buildings collapsed due to sudden loads such as snow loads and wind gusts. In this study, the design and construction of the P.E.B system in Korea were analyzed and its structural safety was evaluated using the finite element analysis program to suggest how to improve the P.E.B system in order to promote the efficient and rational application of the system.

표준축사 모델에서 PEB시스템의 적용 및 구조설계 개선방안 (Solution for the Improvement in Structural Design & Application of PEB System for the Standard Livestock Housing(2008))

  • 박만우;도병호;송준익
    • 한국축산시설환경학회지
    • /
    • 제15권1호
    • /
    • pp.17-28
    • /
    • 2009
  • PEB system is more economical when compared with structures commonly used Hot rolled and welded light H-beam was introduced in the Standard Livestock Housing. This study suggested more economical technology for structural design by the reduction of live load, relief of deflection limit and reduction of importance factor. And, when applying wind Load as a result of examination with Low Rise Building Systems Manual considering open model, we can know that when the wind load is big, enclosed model is more stable than open model. In short, Suggesting more economical model and providing the method to reduce natural disaster, by the application of PEB system and the development of technology for structural design, are considered to strengthen the competitive power of farmhouse.

  • PDF

이음면 이격이 확장형 단부판 이음부 성능에 미치는 영향에 대한 실험적 연구 (Experimental Study of the End-plate Gap Effect on the Performance of Extended End-plate Type Splice)

  • 김철환;이명재;김희동;김사빈
    • 한국강구조학회 논문집
    • /
    • 제28권6호
    • /
    • pp.427-438
    • /
    • 2016
  • 두본 연구는 실험적인 방법을 통하여 단부판 이음부의 이음면에서 초기 오차로 발생하는 이격이 이음부의 내력 및 거동에 미치는 영향을 평가한 연구이다. 이를 위하여 총 5가지의 단순보형 실험체를 확장형 단부판 이음부를 이용 계획하였고 주요 변수로는 이음면 초기 이격(gap) 여부, 고력볼트 채결 전 끼움판(finger shim plate) 설치 유무, 고력볼트 체결 후 이음면 이격, 고력볼트 채결 후 끼움판 삽입 여부를 적용하였다. 정적가력실험 결과 이음판의 이격은 이음부의 최대휨강도에 미치는 영향은 제한적이나 수직변형과 초기 및 탄성강성에는 영향을 미치는 것으로 나타났으며, 이격을 제어하기 위해 고력볼트 장력을 이용할 경우 고력볼트의 취성파괴 우려도 있는 것으로 나타나서 이들에 대한 충분한 고려가 필요할 것으로 판단된다.