• Title/Summary/Keyword: Pre-denitrification

Search Result 27, Processing Time 0.025 seconds

Evaluation of Operational Options of Wastewater Treatment Using EQPS Models (EQPS 모델을 이용한 하수처리장 운전 평가)

  • Yoo, Hosik;Ahn, Seyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.401-408
    • /
    • 2018
  • EQPS (Effluent Quality Prediction System, Dynamita, France) was applied to analyze the appropriateness of the design of a bioreactor in A sewage treatment plant. A sewage treatment plant was designed by setting the design concentration of the secondary clarifier effluent to total nitrogen and total phosphorus, 10 mg/L and 1.8 mg/L, respectively, in order to comply with the target water quality at the level of the hydrophilic water. The retention time of the 4-stage BNR reactor was 9.6 hours, which was 0.5 for the pre-anoxic tank, 1.0 for the anaerobic tank, 2.9 for the anoxic tank, and 5.2 hours for the aerobic tank. As a result of the modeling of the winter season, the retention time of the anaerobic tank was increased by 0.2 hours in order to satisfy the target water quality of the hydrophilic water level. The default coefficients of the one step nitrification denitrification model proposed by the software manufacturer were used to exclude distortion of the modeling results. Since the process modeling generally presents optimal conditions, the retention time of the 4-stage BNR should be increased to 9.8 hours considering the bioreactor margin. The accurate use of process modeling in the design stage of the sewage treatment plant is a way to ensure the stability of the treatment performance and efficiency after construction of the sewage treatment plant.

Demonstration and Operation of Pilot Plant for Short-circuit Nitrogen Process for Economic Treatment of High Concentration Nitrogen Wastewater (고농도 질소함유폐수의 경제적 처리를 위한 단축질소공정 파일럿플랜트 실증화 및 운영 결과)

  • Lee, Jae Myung;Jeon, Ji-hyeong;Choi, Hong-bok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.1
    • /
    • pp.53-64
    • /
    • 2020
  • A 2㎥/d combined wastewater treatment pilot plant containing the multi-stage vertical stacking type nitrification reactor was installed and operated for more than 1 year under the operating conditions of the short-circuit nitrogen process (pH 8, DO 1mg/L and Internal return rate 4Q from nitrification to denitrification reactor). For economically the combination treatment of food wastewater and the leachate from a landfill, the optimal combination ratio was operated by adjusting the food wastewater with the minimum oil content to 5-25% of the total throughput. The main treatment efficiency of the three-phase centrifugal separator which was introduced to effectively separate solids and oil from the food wastewater was about 52% of SS from 116,000mg/L to 55,700mg/L, and about 48% of normal hexane (NH) from 53,200mg to 27,800 mg/L. During the operational period, the average removal efficiency in the combined wastewater treatment process of BOD was 99.3%, CODcr 94.2%, CODmn 90%, SS 70.1%, T-N 85.8%, and T-P 99.2%. The average concentrations of BOD, CODcr, T-N, and T-P of the treated water were all satisfied with the discharge quality standard for landfill leachate ("Na" region), and SS was satisfied after applying the membrane process. On-site leachate had a relatively high nitrite nitrogen content in the combined wastewater due to intermittent aeration of the equalization tanks and different monthly discharges. Nevertheless nitrite nitrogen was accumulated, denitrification from nitrite nitrogen was observed rather than denitrification after complete nitrification. The average input of anti-forming chemical during the operation period is about 2L/d, which seems to be economical compared to the input of methanol required to treat the same wastewater.

The Toxicity Assessment of Explosives Contaminated Soil using Soil Microbial Activity Tests (토양효소활성 측정법을 이용한 화약류 오염토양 독성평가)

  • Kim, Moonkyung;Jung, Jae-Woong;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.6
    • /
    • pp.37-45
    • /
    • 2015
  • This study was conducted to determine the toxic effect of TNT and RDX on indigenous soil microbes by measuring enzymatic activity. Denitrification activity, dehydrogenase activity, phosphatase activity, and fluorescein diacetate hydrolytic activity were determined for military firing range, field, and paddy soils exposed to TNT, and RDX from 0 to 1,000 mg/kg and 0 to 4,000 mg/kg, respectively, for 2, 4, and 8 weeks. Soil microbial enzymatic activities decreased with higher TNT and RDX concentration and longer exposure time. Microbial enzymatic activities of firing range soil were higher than field and paddy soils, indicating that indigenous microbes in firing range might have been adapted to TNT and RDX due to pre-exposure of the explosives. In addition, the toxicity of TNT and RDX decreased with higher organic matter because TNT and RDX tend to absorb to soil organic matter. No Observable Effect Concentration (NOEC) values of each microbial enzymatic activity were derived by the geometric mean of NOECs from exposure times (2, 4, and 8 weeks) and soil types (firing range, field, paddy soil). The derived NOECs ranged from 45.3 to 55.2 mg/kg for TNT and 286 to 309 mg/kg for RDX.

Stability Evaluation of Phased Isolation Intra-Clarifier Ditch Process on Short-Term Hydraulic Shock Loading (단기 수리학적 충격부하시 침전지 내장형 상분리 산화구공정의 처리 안정성 평가)

  • Hong, Ki-Ho;Chang, Duk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.791-799
    • /
    • 2005
  • The phased isolation intra-clarifier ditch system used in this study is a simplified novel process enhancing simultaneous removal of biological nitrogen and phosphorus in municipal wastewater in terms of elimination of additional pre-anaerobic reactor, external clarifier, recycle of sludge, and nitrified effluent recirculation by employing intrachannel clarifier. Laboratory-scale phased isolation ditch system was used to assess the treatability on municipal wastewater. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31days, and cycle times of 2~8hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 70~84%, and 65~90%, respectively. The rainfall in Korea is generally concentrated in summer because of site-specific characteristics. Especially, the wet season has set in on June to August. In combined sewers, seasonal variations are primarily a function of the amount of stormwater that enters the system. In order to investigate the effect of hydraulic shock loading on system performance, the laboratory-scale system was operated at an HRT of 6hours (two times of influent flowrate) during two cycles (8hours). The system performance slightly decreased by increasing of influent flowrate and decreasing of system HRT. Nitrification efficiency and TN removal were slightly decreased by increasing of influent flowrate (decreasing of system HRT), whereas, the denitrification was not affected by hydraulic shock loading. However, the higher system performance could be achieved again after four cycles. Thus, the phased isolation technology for enhanced biological nutrient removal in medium- and small-scale wastewater treatment plants suffering fluctuation of influent quality and flowrate.

Effects of Nitrifying Bacterial Communities with Different HRTs and Backwashing Periods in Modified BAF Process (Modified BAF 공정에서 HRT 및 역세주기가 질산화 미생물의 군집에 미치는 영향)

  • Jung, Chul-Soo;Park, Jeung-Jin;Ju, Dong-Jin;Kwon, Soo-Youn;Choi, Won-Seok;Byun, Im-Gyu;Park, Tae-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.920-926
    • /
    • 2007
  • The upflow Biobead$^{(R)}$ process, one of biological aerated filters (BAF), which was used commercially, invented for removal of organic materials and nitrification. This process was modified to enhance the ability of denitrification through the induction of pre-anoxic tank. In this research, we investigated the effects of hydraulic retention time (HRT) and backwashing period in aerobic tank. The characteristics of nitrifying bacteria, which are composed of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB), also investigated using fluorescence in situ hybridization (FISH). Even though the HRT was shortened, the efficiency of nitrification was not decreased when the organic loading rate and ammonium-nitrogen loading rate were $2.10kg/m^3/day$ and $0.25kg/m^3/day$, respectively. And then the distribution ratios of AOB and NOB showed the similar patterns. However, when the backwashing period was lengthened from 12 hours to 24 hours in aerobic 1 tank, the nitrification efficiency was decreased to 63.9% from 89.2%. The results of FISH explained that this decrease of nitrification efficiency was caused by the decrease of distribution ratio of AOB in aerobic 1 tank. The nitrification efficiencies of aerobic 1 and aerobic 2 tank were increased when the backwashing period was lengthened because of relative high distribution ratios of nitrifying bacteria.

Effect of Microbubble Ozonation Process on Performance of Biological Reactor System for Excess Sludge Solubilisation (마이크로버블오존을 이용한 잉여슬러지 가용화 처리가 생물반응조의 성능에 미치는 영향)

  • Lee, Shun-Hwa;Jung, Kye-Ju;Kwon, Jin-Ha;Lee, Se-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • The study purpose was to examine an effect of zero emission of excess sludge on biological reactor and treated water quality within the biological reactor in the process of biological treatment combined with excess sludge reduction system with ozone. Under an ozone injection rate 0.03 g $O_3/g$ SS, Sludge Disintegration Number (SDN) 3 and less than pH 4 as pre-treatment process, it was possible to maintain a stable biological treatment process without sludge disintegration. In the test of $OUR_{max}$, of sludge, its value was hardly under the condition of ozone injection rate 0.03 g $O_3/g$ SS. There were almost no changes of MLVSS/MLSS within biological reactor followed by a solubilization of excess sludge. Accumulation of microorganism within biological reactor was also not observed. After solubilization of excess sludge, an increase for organic matter and SS concentrations of an effluent was not observed and T-N concentration was reduced by increasing nitrification and denitrification rate within biological reactor. Most of T-P was not removed by zero emission of excess sludge and was leaked by being included in effluents.

Urea Transformation and Nitrogen Loss in Waterlogged Soil Column

  • Seol, Su-Il;Lee, Sang-Mo;Han, Gwang-Hyun;Choi, Woo-Jung;Yoo, Sun-Ho
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.2
    • /
    • pp.86-93
    • /
    • 2000
  • An experiment was conducted to obtain the quantitative data on the transformation and loss of applied urea-N in waterlogged soil columns. The soil columns were pre-incubated for 35 days to develop oxidized and reduced soil conditions prior to urea application. After urea application at the rate of $150kg\;N\;ha^{-1}$(29.5 mg N), the amounts of nitrogen which were volatilized, leached, and remained in soil column were measured during 38 days of incubation period. On 2 and 4 days of incubation, 54.1%(15.9 mg N) and 98.4%(29.0mg N) of the applied urea was hydrolyzed, respectively. Most of the applied urea was completely hydrolyzed within 6 days. After urea application, the rates of ammonia volatilization were increased with the floodwater pH when the floodwater pH were higher than 7.0. The maximum rate of ammonia volatilization was $0.3mg\;d^{-1}$ when pH of the floodwater showed maximum value of 7.6. The total amount of volatilized nitrogen was 6.1% (1.8mg N) of the applied urea-N. A 63.2 % (18.6mg N) of the applied urea was remained in soil as $NH_4{^+}-N$ and 28.0% (8.2mg N) of the applied urea was leached as $NH_4{^+}-N$ at the end of the incubation. Amount of $NO_3{^-}-N$ in soil was smaller than 2.0 mg throughout the incubation period. The total amount of $NO_3{^-}-N$ leached was very small, which value was 1.8 mg. It suggested that nitrification process was not significant in waterlogged soil column of this study due to high infiltration rate of urea solution applied to the soil column. Therefore only small amount of $NO_3{^-}-N$ was lost by denitrification and leaching process.

  • PDF