• Title/Summary/Keyword: Pre Inspection

Search Result 301, Processing Time 0.023 seconds

Detection and Prediction of Subway Failure using Machine Learning (머신러닝을 이용한 지하철 고장 탐지 및 예측)

  • Kuk-Kyung Sung
    • Advanced Industrial SCIence
    • /
    • v.2 no.4
    • /
    • pp.11-16
    • /
    • 2023
  • The subway is a means of public transportation that plays an important role in the transportation system of modern cities. However, congestion often occurs due to sudden breakdowns and system outages, causing inconvenience. Therefore, in this paper, we conducted a study on failure prediction and prevention using machine learning to efficiently operate the subway system. Using UC Irvine's MetroPT-3 dataset, we built a subway breakdown prediction model using logistic regression. The model predicted the non-failure state with a high accuracy of 0.991. However, precision and recall are relatively low, suggesting the possibility of error in failure prediction. The ROC_AUC value is 0.901, indicating that the model can classify better than random guessing. The constructed model is useful for stable operation of the subway system, but additional research is needed to improve performance. Therefore, in the future, if there is a lot of learning data and the data is well purified, failure can be prevented by pre-inspection through prediction.

The Establishment and Improvement of Full Cycle History Management System for Low- and Intermediate-level Radioactive Waste (중저준위 방사성폐기물 전주기 이력관리체계 구축 및 개선)

  • Jin-Woo Lee;Jun Lee;Hee-Chul Eun;Ji-Young Jeong
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.95-100
    • /
    • 2024
  • To establish a radioactive waste life cycle history management system, a series of processes including waste generation, classification, packaging, storage, transportation, and disposal were reflected in the information management system. A preliminary review process was introduced to reduce the amount of radioactive waste generated and manage it efficiently. Through this, the amount of radioactive waste generated must be checked from the beginning of the research, and the generated radioactive waste must be thoroughly managed from the stage of generation to final disposal. In particular, in the case of radioactive waste data generated during nuclear facility operation and each experiment, a radioactive waste information management system must be operated to receive information from the waste generator and integrate it with processing information at the management stage. The application process for small-package containers was reflected so that information such as the generation facility of radioactive waste, generation facility, project information, types of radioactive waste, major radionuclides, etc. In the radioactive waste management process, the preceding steps are to receive waste history from the waste generators. This includes an application for a specified container with a QR label, pre-inspection, and management request. Next, the succeeding steps consist of repackaging, treatment, characterization, and evaluating the suitability of disposal, for a process to transparently manage radioactive wastes.

Modeling and Validation of Population Dynamics of the American Serpentine Leafminer (Liriomyza trifolii) Using Leaf Surface Temperatures of Greenhouses Cherry Tomatoes (방울토마토에서 잎 표면온도를 적용한 아메리카잎굴파리(Liriomyza trifolii) 개체군 밀도변동 모형작성 및 평가)

  • Park, Jung-Joon;Mo, Hyoung-Ho;Lee, Doo-Hyung;Shin, Key-Il;Cho, Ki-Jong
    • Korean journal of applied entomology
    • /
    • v.51 no.3
    • /
    • pp.235-243
    • /
    • 2012
  • Population dynamics of the American serpentine leafminer, Liriomyza trifolii (Burgess), were observed and modeled in order to compare the effects of air and tomato leaf temperatures inside a greenhouse using DYMEX model builder and simulator (pre-programed module based simulation programs developed by CSIRO, Australia). The DYMEX model simulator consisted of a series of modules with the parameters of temperature dependent development and oviposition models of L. trifolii were incorporated from pre-published data. Leaf surface temperatures of cherry tomato leaves (cv. 'Koko') were monitored according to three tomato plant positions (top, > 1.8 m above the ground level; middle, 0.9 - 1.2 m; bottom, 0.3 - 0.5 m) using an infrared temperature gun. Air temperature was monitored at the same three positions using a self-contained temperature logger. Data sets for the observed air temperature and average leaf surface temperatures were collected (top and bottom surfaces), and incorporated into the DYMEX simulator in order to compare the effects of air and leaf surface temperature on the population dynamics of L. trifolii. The initial population consisted of 50 eggs, which were laid by five female L. trifolii in early June. The number of L. trifolii larvae was counted by visual inspection of the tomato plants in order to verify the performance of DYMEX simulation. The egg, pupa, and adult stage of L. trifolii could not be counted due to its infeasible of visual inspection. A significant positive correlation between the observed and the predicted numbers of larvae was found when the leaf surface temperatures were incorporated into the DYMEX simulation (r = 0.97, p < 0.01), but no significant positive correlation was observed with air temperatures(r = 0.40, p = 0.18). This study demonstrated that the population dynamics of L. trifolii was affected greatly by the leaf temperatures, though to little discernible degree by the air temperatures, and thus the leaf surface temperature should be for a consideration in the management of L. trifolii within cherry tomato greenhouses.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

Radiation Exposure Dose Reduction on Upper Gastrointestinal Series (위장조영검사에서 피폭선량 저감)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2017
  • Upper gastrointestinal series is non-invasive examination, and it is useful for patients or elderly patients who have difficulty in endoscopic examination because of absence of any side effects other than temporary constipation or abdominal pain. The entire image of the gastrointestinal tract can be seen and have been widely used in the diagnosis of upper gastrointestinal diseases. However, there is a possibility that radiation dose increases due to improper movement and breath control, when examination is carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. In upper gastrointestinal series to increase understanding of examination, to induce appropriate cooperation during examination, to reduce the number of retakes and shorten examination time, and to reduce dose of the subject, the procedure and precautions of the gastrointestinal test were made as a movie. We investigated the effectiveness of pre-education using the movie to reduce the inspection time, the number of re-shoots, and the reduction of exposure dose by watching the movie during the waiting time before examination. 120 patients that were selected each 20 patients aged from 30s to 80s were evaluated were evaluated for exposure dose, examination time, and the number of retakes before and after the movie training. The radiation dose, the examination time, and the number of retakes were respectively $3171.83{\mu}Gy{\cdot}m^2$ and $2931.73{\mu}Gy{\cdot}m^2$, 8.05 min, and 6.75 min, and 1.68 times and 1.22 times before and after movie training. It can be concluded that the movie training on the gastrointestinal examination influences the reduction of the examination time, the number of retakes and the reduction of the radiation dose.

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

A Development of Facility Web Program for Small and Medium-Sized PSM Workplaces (중·소규모 공정안전관리 사업장의 웹 전산시스템 개발)

  • Kim, Young Suk;Park, Dal Jae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.334-346
    • /
    • 2022
  • There is a lack of knowledge and information on the understanding and application of the Process Safety Management (PSM) system, recognized as a major cause of industrial accidents in small-and medium-sized workplaces. Hence, it is necessary to prepare a protocol to secure the practical and continuous levels of implementation for PSM and eliminate human errors through tracking management. However, insufficient research has been conducted on this. Therefore, this study investigated and analyzed the various violations in the administrative measures, based on the regulations announced by the Ministry of Employment and Labor, in approximately 200 small-and medium-sized PSM workplaces with fewer than 300 employees across in korea. This study intended to contribute to the prevention of major industrial accidents by developing a facility maintenance web program that removed human errors in small-and medium-sized workplaces. The major results are summarized as follows. First, It accessed the web via a QR code on a smart device to check the equipment's specification search function, cause of failure, and photos for the convenience of accessing the program, which made it possible to make requests for the it inspection and maintenance in real time. Second, it linked the identification of the targets to be changed, risk assessment, worker training, and pre-operation inspection with the program, which allowed the administrator to track all the procedures from start to finish. Third, it made it possible to predict the life of the equipment and verify its reliability based on the data accumulated through the registration of the pictures for improvements, repairs, time required, cost, etc. after the work was completed. It is suggested that these research results will be helpful in the practical and systematic operation of small-and medium-sized PSM workplaces. In addition, it can be utilized in a useful manner for the development and dissemination of a facility maintenance web program when establishing future smart factories in small-and medium-sized PSM workplaces under the direction of the government.

Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection (하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구)

  • An, Hyeong-Theck;Kim, Jae-Yeol;Yeo, Woon-Sik;Park, Yong-Sung;Lee, Gui-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

Clinical Experience with Colonic Atresia (선천성 결장 폐쇄증의 경험)

  • Hwang, Jihee;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.18 no.2
    • /
    • pp.68-74
    • /
    • 2012
  • Colonic atresia (CA) is the rare cause of intestinal obstruction, and diagnosis of CA is difficult. But only few research has been performed, so little information has been available. The purposes of this study was to analyze the clinical findings of CA so that help physicians make decision properly. Children with CA who were treated at the division of pediatric surgery at Asan Medical Center in the period from January 1989 to December 2011 were evaluated retrospectively. A total of 6 children were treated with CA. These accounted for 2.7% of all gastrointestinal atresias managed in Asan Medical Center. Only one child was premature and low birth weight, the others were fullterm neonates and showed normal birth weight. Vomiting and abdominal distension were common symptoms and simple X-ray and barium study were used for diagnose of CA. But only 66.7% of the babies were diagnosed as CA pre-operatively. And 2 children out of 6 underwent re-operation due to missed CA at the time of the first operation. In aspect of types of atresia, the type IIIa were two, type IV were two, type I was one case, and one child showed rectal stenosis due to rectal web. Various operations were done according to individual findings and associated diseases. The 50% (n=3) of children underwent the primary anastomosis and the others (n=3) underwent colostomy first and staged operation later for missed CA or associated disease. All of them were recovered any significant complications. Therefore, the prognosis of CA is satisfactory if diagnosis and surgical management could be made properly. But because of the low incidence of CA, delay of diagnosis and treatment may occur. To prevent delay of diagnosis, we suggest prompt evaluation of doubtful infant and careful inspection of distal patency of bowel including whole colon and rectum when operating patients with intestinal atresia at any level.

  • PDF

A Study on the Recognition and Enforcement of Arbitral Awards Applied Public Policy by Chinese Court (중국 법원의 중재판정 승인 및 집행에서 공공질서 적용에 관한 연구)

  • Ha, Hyun-Soo
    • Journal of Arbitration Studies
    • /
    • v.21 no.3
    • /
    • pp.115-136
    • /
    • 2011
  • In the past, Chinese arbitral system and Chinese arbitral associations were avoided by international society due to the cases which Chinese court rejected the recognition and enforcement of foreign arbitral awards based on rural protection. Especially Chinese court adjudicated to reject the recognition and enforcement of arbitral awards by interpreting public policy broadly. The abuse of public policy by court threats the existence of commercial arbitration system. Under this awareness, the author figured out Chinese court shows what kind of attitude about public policy of Chinese court in the present through analyzing the cases about rejection of enforcement in Chinese arbitral awards in order to analyze whether Chinese court still maintain the negative attitude like past or there exist changes with public policy which is one of the rejection reasons of recognition and enforcement in foreign arbitral awards as the central figure. Chinese court behaved in an uncooperative attitude about arbitral awards like that it reached a verdict to reject the enforcement of arbitral awards by reason of violation in public policy about several foreign arbitral awards at the beginning stage of establishing arbitration law. However, the situation of abuse in public policy was improved a lot by Chinese prime court which enforces pre-inspection system about judgment of rejection of enforcement in arbitral awards. So, there is no case about rejecting the approval and enforcement of arbitral awards by reason of violation in public policy by Chinese court except Yongning Co. case. Moreover, Chinese court got the trust and support from other countries through reinforcement of applied standard. However, Chinese court had been expressed concern from international society because they highly applied public policy and rejected to enforce arbitral awards in the recent case of Yongning Co.. Therefore, this study examined whether it is appropriate to apply public policy of Chinese court in the case of Yongning Co., and then I concluded that. Although Yongning Co. case is the first case which Chinese prime court agrees with public policy by reason of rejection of approval and enforcement in foreign arbitral awards, in my opinion, it doesn't mean that Chinese court has fundamental change in basic attitude and position about the approval and enforcement of foreign arbitral awards. Chinese court keeps the cautious uses of public policy in legal judgment of foreign arbitral awards and it looks like implementing the obligation in regulation of New York Convention sincerely.

  • PDF