• 제목/요약/키워드: Practice parameter

검색결과 202건 처리시간 0.029초

수직형 지중열교환기 열전도도 측정기술에 관한 연구 (A Study on the Measurement of Thermal conductivity of Vertical Borehole heat Exchanger)

  • 김지영;이의준;장기창;강은철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.39-44
    • /
    • 2008
  • The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic response test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless P/T probe for a hi-speed k determination was introduced in this paper. This technique using a wireless P/T probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. In order to verify the new technique for the determination of ground thermal conductivity, ground thermal conductivity k that calculated from the measured temperature data using a wireless P/T probe was compared with one obtained from conventional hydraulic TRT. When comparing the average k of two methods, the relative error was approximately 10%. As a result, the electronic TRT can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of sites.

  • PDF

Base Isolation System이 있는 건물의 지진하중에 대한 동적해석 (Semismic Analysis of Building Structures with Base Isolation System)

  • 이동근;이정석
    • 전산구조공학
    • /
    • 제3권1호
    • /
    • pp.71-81
    • /
    • 1990
  • Base isolation system은 구조물의 기초하부에 설치되며 지진에 의한 구조물의 피해를 감소시켜 준다. 지금까지 많은 공학들에 의해 여러가지 base isolation system이 개발되었으나 실용화된 것은 1970년대에 laminated rubber bearing(LR type)이 개발되고서부터 였다. 최근에는 laminated rubber bearing밑에 미끄럼판을 둔 새로운 base isolation system(SR type)이 개발되었다. 본 연구에서는 isolation system과 구조물의 여러가지 성질에 따른 isolation효과에 대한 연구를 수행하였다. 이 연구의 결과, isolaion system은 지진하중이 작용할 때 건물에 발생하는 피해를 상당히 감소시킴을 알 수 있으며, isolaion system의 주기가 길어짐에 따라 isolation효과는 증가함을 알 수 있다. 그리고 건물의 높이가 증가함에 따라 isolation효과는 줄어든다는 것을 알 수 있다. SR type isolation system이 있는 건물에 지진하중이 작용할 때, 건물내부에서 발생하는 가속도와 층간변위, 그리고 전체변위는 LR type의 경우보다 작으므로 보다 효율적이라는 것을 알 수 있다.

  • PDF

Influence of the cylinder height on the elasto-plastic failure of locally supported cylinders

  • Jansseune, Arne;De Corte, Wouter;Vanlaere, Wesley;Van Impe, Rudy
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.291-302
    • /
    • 2012
  • Frequently, steel silos are supported by discrete supports or columns to permit easy access beneath the barrel. In such cases, large loads are transferred to the limited number of supports, causing locally high axial compressive stress concentrations in the shell wall above the supports. If not dealt with properly, these increased stresses will lead to premature failure of the silo due to local instability in the regions above the supports. Local stiffening near the supports is a way to improve the buckling resistance, as material is added in the region of elevated stresses, levelling these out to values found in uniformly supported silos. The aim of a study on the properties of local stiffening will then be to increase the failure load, governed by an interaction of plastic collapse and elastic instability, to that of a discrete supported silo. However, during the course of such a study it was found that, although the failure remains local, the cylinder height is also a parameter that influences the failure mechanism, a fact that is not properly taken into account in current design practice and codes. This paper describes the mechanism behind the effect of the cylinder height on the failure load, which is related to pre-buckling deformations of the shell structure. All results and conclusions are based on geometrically and materially non-linear finite element analyses.

UHPC 바닥판 철근겹침이음 연결부의 휨강도 평가 (Evaluation of Flexural Strength for UHPC Deck Joints with Lap-Spliced Reinforced Steel Bar)

  • 황훈희;여인수;조근희;박성용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.92-99
    • /
    • 2011
  • 초고성능콘크리트(Ultra High Performance Concrete, UHPC)는 높은 강도와 내구성을 가지는 우수한 구조재료이다. 이러한 새로운 재료의 활용 기술은 경량의 슬림한 구조로서 우수한 성능을 가지는 구조물의 건설을 실현할 수 있는 효과적인 방안으로 주목받고 있다. 이 연구는 하이브리드 사장교 적용을 위한 UHPC프리캐스트 바닥판 시스템 개발의 일부로서 정모멘트 구간에서 철근겹침이음 방식에 의하여 연결되는 이음부의 거동 특성을 실험적으로 규명하는데 주된 목적이 있다. 주요 실험변수는 철근겹침이음길이이며 실험변수의 영향을 검증하기 위하여 총 12개의 휨실험체를 제작하였고, 이에 대한 4점 휨재하실험을 수행하였다. 현행 도로교설계기준에서 철근겹침이음에 대한 최소길이 규정은 UHPC를 적용한 프리캐스트 바닥판 시스템에서는 매우 보수적인 규정임을 실험결과로부터 확인할 수 있었다.

Monolithic zirconia crowns: effect of thickness reduction on fatigue behavior and failure load

  • Prott, Lea Sophia;Spitznagel, Frank Akito;Bonfante, Estevam Augusto;Malassa, Meike Anne;Gierthmuehlen, Petra Christine
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.269-280
    • /
    • 2021
  • PURPOSE. The objective of this study was to evaluate the effect of thickness reduction and fatigue on the failure load of monolithic zirconia crowns. MATERIALS AND METHODS. 140 CAD-CAM fabricated crowns (3Y-TZP, inCorisTZI, Dentsply-Sirona) with different ceramic thicknesses (2.0, 1.5, 1.0, 0.8, 0.5 mm, respectively, named G2, G1.5, G1, G0.8, and G0.5) were investigated. Dies of a mandibular first molar were made of composite resin. The zirconia crowns were luted with a resin composite cement (RelyX Unicem 2 Automix, 3M ESPE). Half of the specimens (n = 14 per group) were mouth-motion-fatigued (1.2 million cycles, 1.6 Hz, 200 N/ 5 - 55℃, groups named G2-F, G1.5-F, G1-F, G0.8-F, and G0.5-F). Single-load to failure was performed using a universal testing-machine. Fracture modes were analyzed. Data were statistically analyzed using a Weibull 2-parameter distribution (90% CI) to determine the characteristic strength and Weibull modulus differences among the groups. RESULTS. Three crowns (21%) of G0.8 and five crowns (36%) of G0.5 showed cracks after fatigue. Characteristic strength was the highest for G2, followed by G1.5. Intermediate values were observed for G1 and G1-F, followed by significantly lower values for G0.8, G0.8-F, and G0.5, and the lowest for G0.5-F. Weibull modulus was the lowest for G0.8, intermediate for G0.8-F and G0.5, and significantly higher for the remaining groups. Fatigue only affected G0.5-F. CONCLUSION. Reduced crown thickness lead to reduced characteristic strength, even under failure loads that exceed physiological chewing forces. Fatigue significantly reduced the failure load of 0.5 mm monolithic 3Y-TZP crowns.

잠재변수 모형에서의 군집효율을 이용한 변수선택 (Variable selection for latent class analysis using clustering efficiency)

  • 김성경;서병태
    • 응용통계연구
    • /
    • 제31권6호
    • /
    • pp.721-732
    • /
    • 2018
  • 잠재집단 모형은 다변량 범주형 자료 안에 숨겨진 집단을 찾는 매우 중요한 도구종의 하나이다. 하지만 실제 자료분석에서 너무 많은 관찰변수들을 포함시킨 모형은 모형을 복잡하게 만들고 또한 모수추정의 정확도에 영향을 주기 때문에 정보가 손실되지 않는 내에서 유용한 변수를 찾는 것은 중요한 문제이다. Dean과 Raftery (2010)은 잠재집단 모형에서의 변수선택을 위해 BIC를 이용한 Headlong search 알고리즘을 제시하였는데 본 논문에서는 이 방법을 대체할 수 있는 방법으로 적합한 모형으로부터 계산된 잠재집단에 속할 사후확률을 이용하여 변수 선택을 하는 방법을 제안하고자 한다. 이를 위하여 잠재집단 모형의 적합성을 측정할 수 있는 새로운 통계량과 이를 이용한 변수선택 알고리즘을 제시할 것이다. 또한 제안된 방법의 효율성을 모의실험과 실증자료 분석을 통해 살펴보고자 한다.

Nursery Growing Media Practice: Impact on Seed Germination and Initial Seedling Development of Hymenodictyon orixensis (Roxb.) Mabberley - A Vulnerable Native Tree Species

  • Islam, Azharul;Hao, Hong;Hossain, Mohammed Kamal;Rahman, Mahmudur
    • Journal of Forest and Environmental Science
    • /
    • 제38권1호
    • /
    • pp.38-47
    • /
    • 2022
  • Hymenodictyon orixensis (Roxb.) Mabberley (locally known as Bhutum in Bangladesh) is both an ecologically and economically valuable multipurpose tree species for afforestation and reforestation programs in Bangladesh. Seed germination and seedling development study of H. orixense were conducted to find out the response to different growing medium, e.g., polybag (15×10 cm (T0) and 20×15 cm (T1)), sand medium in propagator house (T2), conventional nursery bed (T3), and root trainer (T4) in the Nursery. Consequently, germination behavior and seedling morphological parameters of H. orixense were assessed. The results revealed that the sand medium of the propagator house (T2) provided the highest germination % (58.57±22.30) and the highest germination energy (11.43±2.43) followed by seedlings growing in 20×15 cm polybags (T1) containing forest topsoil and cow-dung at a ratio of 3:1. Except for germination energy, germination values, and germination capacity, other seed biology parameters, particularly imbibition, germination period, germination rate, and plant survival percent in T1, T2, T3, and T4 were significantly (p<0.05) different from T0. Each phenotypic parameter of seedlings and dry matter of shoot and root significantly differed from control except root length (p<0.992). Based on this study, Polybags of 20×15 cm size are regarded as the best medium for quality seedling development of H. orixense. The nursery bed (T3) had the lowest germination performance and developed more inferior quality seedlings. Thereby, 20×15 cm size of polybags with conventional soil and cow-dung media is recommended for maximum germination and to grow the quality seedlings of H. orixense in the Nursery.

Success rate of nitrous oxide-oxygen procedural sedation in dental patients: systematic review and meta-analysis

  • Rossit, Marco;Gil-Manich, Victor;Ribera-Uribe, Jose Manuel
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권6호
    • /
    • pp.527-545
    • /
    • 2021
  • The aim of this systematic review was to determine the success rate of nitrous oxide-oxygen procedural sedation (NOIS) in dentistry. A systematic digital search was conducted for publications or reports of randomized controlled trials evaluating the clinical performance of NOIS. Abstracts of research papers were screened for suitability, and full-text articles were obtained for those who met the inclusion and exclusion criteria accordingly. The quality of the studies was assessed using the revised Cochrane risk-of-bias tool (RoB 2). A total of 19 articles (eight randomized clinical trials with parallel intervention groups and 11 crossover trials), published between May 1988 and August 2019, were finally selected for this review. The studies followed 1293 patients reporting NOIS success rates, with a cumulative mean value of 94.9% (95% CI: 88.8-98.9%). Thirteen trials were conducted on pediatric populations (1098 patients), and the remaining six were conducted on adults (195 patients), with cumulative efficacy rates of 91.9% (95% CI: 82.5-98.1%) and 99.9% (95% CI: 97.7-100.0%), respectively. The difference was statistically significant (P = 0.002). Completion of treatment and Section IV of the Houpt scale were the most used efficacy criteria. Within the limitations of this systematic review, the present study provides important information on the efficacy rate of NOIS. However, further well-designed and well-documented clinical trials are required and there is a need to develop guidelines for standardization of criteria and definition of success in procedural sedation. Currently, completion of treatment is the most used parameter in clinical practice, though many others also do exist at the same time. To maximize NOIS efficacy, clinicians should strictly consider appropriate indications for the procedure.

Assessment of the severe accident code MIDAC based on FROMA, QUENCH-06&16 experiments

  • Wu, Shihao;Zhang, Yapei;Wang, Dong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.579-588
    • /
    • 2022
  • In order to meet the needs of domestic reactor severe accident analysis program, a MIDAC (Module Invessel Degraded severe accident Analysis Code) is developed and maintained by Xi'an Jiaotong University. As the accuracy of the calculation results of the analysis program is of great significance for the formulation of severe accident mitigation measures, the article select three experiments to evaluate the updated severe accident models of MIDAC. Among them, QUENCH-06 is the international standard No.45, QUENCH-16 is a test for the analysis of air oxidation, and FROMA is an out-of-pile fuel rod melting experiment recently carried out by Xi'an Jiaotong University. The heating and melting model with lumped parameter method and the steam oxidation model with Cathcart-Pawel and Volchek-Zvonarev correlations combination in MIDAC could better meet the needs of severe accident analysis. Although the influence of nitrogen still need to be further improved, the air oxidation model with NUREG still has the ability to provide guiding significance for engineering practice.

Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers

  • Ro, Younghye;Choi, Woojae;Hong, Leegon;Kim, Eunkyung;Choe, Eunhui;Kim, Danil
    • Journal of Veterinary Science
    • /
    • 제23권4호
    • /
    • pp.60.1-60.6
    • /
    • 2022
  • Background: A definite diagnosis should be made in the bovine practice field, however, it was difficult to perform laboratory analysis immediately. Currently, three types of portable blood gas analyzers are available in Korea. Objectives: This study aimed to evaluate the correlations among these three analyzers. Methods: Seventy-two plasma samples from Holstein-Friesian cows were used for blood gas analysis, and three instruments (EDAN i15 Vet, VETSCAN i-STAT, and EPOC) were operated simultaneously. Moreover, plasma calcium levels were compared between these portable analyzers and blood chemistry device, which is usually used in a laboratory environment. Pearson analysis was performed to confirm the correlation of each parameter produced with the three instruments and blood chemistry analyzer. Results: As results, high correlation was observed in parameters of pH, pO2, potassium ion, ionized calcium, and glucose (p < 0.001, r > 0.7). In addition, pCO2 showed a moderate correlation among the three analyzers (p < 0.001, r > 0.5), and there was no correlation among all instruments for sodium ions. There was also a high correlation between ionized calcium from the three portable devices and total calcium from the biochemistry analyzer (p < 0.001, r > 0.9). Conclusions: In conclusion, there was a high correlation between results from the three different blood gas analyzers used in the bovine clinical field in Korea. Thus, a consistent diagnosis can be made even with different equipment if the operator is aware of the strengths and weaknesses of each piece of equipment and operates it properly.