A Study on Structural Intensity Measurement of Semi-infinite Beam (반무한보의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF

A Study of the Improvement and Practical Use on the Website Measurement Scale (웹사이트 측정도구의 개발과 활용에 대한 연구)

  • Kim, Dae-Hwan;Bae, Young
    • Survey Research
    • /
    • v.10 no.1
    • /
    • pp.91-112
    • /
    • 2009
  • The aim of this study is to suggest a new website measurement scale revised in accordance with the present tendency, and to test the practical use of it. The empirically current studies suggest the information, connectivity, practical function, lay - out, design, interlace, system, service as a website measurement scale. However. this study suggest a new website measurement scale including communication between internet users, platform for editing information. The test of a practical use about measurement scale progressed by a survey on computer access. A sample of 300 internet users answered the question based on a new website measurement scale. The result of this study shows that primary factors of the website measurement scale are information, user interface, website service, and communication. The influence of these factors on user's website preference changed as compared with the past. The result also shows that there is close correlation between information factor and communication factor. And the communication factor suggested on this study has effected in user's website satisfaction. Results imply that the idea of web2.0 is practically an important strategy for improving website satisfaction. And, because influence of primary factors on the website satisfaction has changed continually, strategic planning will have to be kept up.

  • PDF

A Study on a Hartmann Test of Optical Mirror for On-Machine Measurement of Polishing machine (광학면 연마기의 OMM을 위한 Hartmann Test 방법 연구)

  • 김옥현;이응석;오창진;김용관
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.40-45
    • /
    • 2004
  • Recently, aspheric optical lenses and mirrors, which are harder to manufacture and measure than the conventional spherical ones, are widely used, particularly in electronic fabrication process. Generally, interferometric optical method is used for the measurement of spherical optical surface. However, the interferometric method for aspheric surface measurement is difficult because it needs a precise null corrector and strict environmental conditions such as constant temperature, humidity and vibrations. We have been studied on the manufacturing of aspheric optics to improve the surface profile accuracy and productivity using a corrective polishing process. For the corrective polishing, a practical method of On-Machine Measurement (OMM) is required. For this purpose, an optical OMM system has been studied using the Shach-Hartmann test, which is very robust to the practical polishing environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by the least squares fitting. The measured result of the OMM system shows that the maximum deviation is less than 200 nm for the one of commercial Fizeau interferometer Wyko 6000.

Binary Sequence Family for Chaotic Compressed Sensing

  • Lu, Cunbo;Chen, Wengu;Xu, Haibo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4645-4664
    • /
    • 2019
  • It is significant to construct deterministic measurement matrices with easy hardware implementation, good sensing performance and good cryptographic property for practical compressed sensing (CS) applications. In this paper, a deterministic construction method of bipolar chaotic measurement matrices is presented based on binary sequence family (BSF) and Chebyshev chaotic sequence. The column vectors of these matrices are the sequences of BSF, where 1 is substituted with -1 and 0 is with 1. The proposed matrices, which exploit the pseudo-randomness of Chebyshev sequence, are sensitive to the initial state. The performance of proposed matrices is analyzed from the perspective of coherence. Theoretical analysis and simulation experiments show that the proposed matrices have limited influence on the recovery accuracy in different initial states and they outperform their Gaussian and Bernoulli counterparts in recovery accuracy. The proposed matrices can make the hardware implement easy by means of linear feedback shift register (LFSR) structures and numeric converter, which is conducive to practical CS.

A Study for sensorless Control of Brushless DC-Minimotor (Blushless 직류 소형모터의 sensorless 제어에 대한 연구)

  • 김인구;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.99-104
    • /
    • 2000
  • This paper present the design, produce, circuit design and practical measurement for a Brushless DC Motor(BLDCM) with Ferrit-Magnet. It was used PI controller. The practical PI control has bin widely used for DC-Motor.

  • PDF

Parameter Measurement of Induction Motors

  • Kim Kyung-Seo;Byun Sung-Hoon;Na Seung-Ho;Cho Byung-Guk;Kwon Bong-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.751-755
    • /
    • 2001
  • This paper presents the parameter measurement methods for high performance drive of induction motors. The proposed methods are selected by considering the factors that affect accuracy of measurement. Each method are refined to be adequate for measurement of each motor parameters. Proposed methods are easy to implement and only require inverter-motor system, which are important for practical application.

  • PDF

Vision Inspection Module for Dimensional Measurement in CMM having Vision Probe (비젼프로브를 가지는 3차원 측정기를 위한 형상 측정 시스템 묘듈 개발)

  • 이일환;박희재;김구영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.379-383
    • /
    • 1995
  • In this paper, vision inspection module for dimensional measurement has been developed. For high accuracy of CMM, camera calibration and edge detection with subpixel accuracy have been implemented. In measurement process, the position of vision probe can be recognized in PC by serial communication with CMM controller. The developed vision inspection module can be widely applied to the practical measurement process.

  • PDF

Development of a Practical Field Data Acquisition Device for Civil and Environmental Engineering Applications (토목환경공학분야의 응용을 위한 실용적인 현장자료수집기의 개발)

  • 여운광;윤병만;이종국;허정호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.9 no.4
    • /
    • pp.176-181
    • /
    • 1997
  • A practical, easy-to-use data acquisition device has been developed for use in civil and envirionmental engineering applications. It uses the PC parallel port for the acquisition and data transfer and is simple enough to be setup and run in laboratory and field experiment conditions. The usual limitations of data storage capacity of several data loggers was solved by using PC resources. Also versatile programming capability using high level languages of the PC programming environment such as C and Visual Basic enables the data acquisition device to be configured as a general and practical data acquisition system. An example of effective uses of the device is. provided for the water environment measurement at the Bangwha bridge construction site. The in site. test proved the device to be practical in civil and environmental engineering applications.

  • PDF

A Study on the Measurement Uncertainty of Flowmeter Calibrator (유량계 교정장치의 측정불확도에 관한 연구)

  • Im, Gi-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

Temperature and Concentration measurement using Semi-conductor diode laser (반도체레이져를 이용한 온도 및 농도의 계측)

  • Chung, D.H.;Noh, D.S.;Ikeda, Yuji
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF