• Title/Summary/Keyword: Powerplant

Search Result 28, Processing Time 0.024 seconds

Study on New Airworthiness Requirements of Powerplant System for the Small Airplane (소형 비행기 동력장치에 관한 신규 인증요건 분석)

  • Lee, Eunsuk;Lee, Seung geun;Lee, Kang-Yi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.207-212
    • /
    • 2017
  • Korean civil airworthiness requirements of powerplant system are regulated on KAS Part 23 and Part 33. These are equivalent to FAR Part 23, Part 33 of FAA and CS-23, CS-E of EASA. FAA and EASA rewrites entire airworthiness requirements for the small airplane. It changed current 'prescriptive regulation' into 'performance-based regulation' which makes the object of safety performance. Powerplant requirements are also changed extensively by these concept revolution. In accordance with reorganization, we studied new powerplant system requirements of FAR Part 23 and proposed ideal direction to rewrite of Korean Airworthiness Standard rewrite.

  • PDF

Study on New Airworthiness Requirements of Powerplant System for the Small Airplane (소형 비행기 동력장치에 관한 신규 인증요건 분석)

  • Lee, Eunsuk;Lee, Seung geun;Lee, Kang-Yi
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2018
  • Korean civil airworthiness requirements of powerplant system are regulated by KAS(Korean Airworthiness Standard) Part 23 and Part 33. These are equivalent to FAR Part 23, Part 33 of FAA, and CS-23 and CS-E of EASA. FAA and EASA rewrite the airworthiness requirements for small airplane. They changed current 'prescriptive regulation' to a 'performance-based regulation' which makes safety performance the objective. Powerplant requirements have also been changed extensively by this concept revolution. In accordance with this reorganization, we studied the new powerplant system requirements of FAR Part 23 and proposed ideal directions to rewrite the Korean Airworthiness Standard.

Vibration Control of Condensate Motors in Nuclear Powerplant By Bearing Redesign (베어링 재설계에 의한 원전 COP motor의 진동 제어)

  • Lim, Do-Hyeong;Kim, Won-Hyun;Lee, Jong-Moon;Lee, Soo-Mok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the summary of control of abnormal vibration found in the COP motors of a nuclear power plant. All six identical units of COP pump-motor assemblies showed unstable vibration pattern of which one or two showed higher vibration enough to exceed the allowable level from the installation stage. Many trials of test, measurement, overhaul and replacement had been repeated to investigate and solve the problem but only to reach unsatisfactory settlement. Recently several times of site tests are made and followed by significant diagnostic actions in which the authors group participated. It was found that the coupled shafting system of motor and pump is in close resonance with the $1^{st}$ shaft rotating speed. Redesign of topside motor bearing clearance is made to increase bearing stiffness and hence to avoid the resonance which consequently led to reduce the troubled vibration to allowable and stable status.

  • PDF

Analysis of Fluid-elastic Instability In the CE-type Steam Generator Tube (CE형 증기발생기 전열관에 대한 유체탄성 불안정성 해석)

  • 박치용;유기완
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.4
    • /
    • pp.261-271
    • /
    • 2002
  • The fluid-elastic instability analysis of the U-tube bundle inside the steam generator is very important not only for detailed design stage of the SG but also for the change of operating condition of the nuclear powerplant. However the calculation procedure for the fluid-elastic instability was so complicated that the consolidated computer program has not been developed until now. In this study, the numerical calculation procedure and the computer program to obtain the stability ratio were developed. The thermal-hydraulic data in the region of secondary side of steam generator was obtained from executing the ATHOS3 code. The distribution of the fluid density can be calculated by using the void fraction, enthalpy, and operating pressure. The effective mass distribution along the U-tube was required to calculate natural frequency and dynamic mode shape using the ANSYS ver. 5.6 code. Finally, stability ratios for selected tubes of the CE type steam generator were computed. We considered the YGN 3.4 nuclear powerplant as the model plant, and stability ratios were investigated at the flow exit region of the U-tube. From our results, stability ratios at the central and the outside region of the tube bundle are much higher than those of other region.

Present situation and utilization-rate of a mass solar-powerplant in Korea (우리나라 대용량 태양광발전 현황 및 이용률 분석)

  • Shin, Yong-Son;Jung, Rae-Hyuck;Ko, Jae-Whan;Jeon, Jong-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.469-471
    • /
    • 2008
  • 본 논문에서는 최근 급격히 증가하는 태양광산업에 대해, 전력시장에 등록된 200kW 초과 대용량 태양광발전소를 대상으로 기간별 증감추이 및 지역별 현황을 파악하고, 발전소 위치 및 이용률 분석을 통해 일조량과 바람 등이 태양광발전에 미치는 영향을 확인해 보고자 한다.

  • PDF

The study on Intergrated SCADA system for Powerplant using Soft logic (SOFT LOGIC을 이용한 전력설비 통합제어 시스템구축에 관한 연구)

  • Cho, Nam-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2443-2445
    • /
    • 2000
  • In this paper, the Intergrated SCADA is used to computer systems designed to perform the following functions for power plant. - to collect data from industrial plant devices or transducers - to process and perform calculations on the collected data - to present collected and derived data on displays on MMI - to accept commands entered by human operators and act on them such as sending control commands to plant devices. This system is characterised by open architectured that is based on the internationally recognized industrial standard for industrial automation control language, the IEC 1131-3

  • PDF

Case Study on Certification System of Parts Repair for Commercial Aircraft Engine (상용항공기 엔진부품 수리 인증체계에 관한 사례연구)

  • Chang-Tak Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.4
    • /
    • pp.95-103
    • /
    • 2023
  • Aircraft engine parts repair is a field belonging to the lowest level in the hierarchy of the aircraft industry, and it is marginalized in terms of research, compared to aircraft manufacturing or maintenance that belong to the upper level. On the other hand, in 2019, Korean Air's Powerplant Maintenance Center paid USD $130 million to foreign countries for engine parts repair, making it an industry with great need for localization. To achieve the goal of localizing engine parts repair, a certification system is needed that can perform independent repairs based on the development of repair technology, aligning contractual relationships with engine manufacturers, and free from dependence on engine manufacturers or foreign repair companies. The purpose of this study is to provide a basis for subsequent research to secure an actual certification system by suggesting the need for securing such a certification system.

A development of reliability evaluation model for power plant fan pitch blade control actuator (발전설비 통풍기 날개각 제어작동기 신뢰성평가 모델 개발)

  • Son, Tae-Ha;Huh, Jun-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3259-3263
    • /
    • 2007
  • This paper describes the proceedings of creating countermeasures after analysis and maintenance be able to conduct operation safely in a power plant. in order to operate the power plant in a stable and reliable way, the best condition of the govemor system can be maintained through the response characteristic analysis of the control device for the pitch blade control hydraulic actuator. The fan pitch blade control hydraulic actuator of a 500MW large-scale boiler is frequently operated under normal operation conditions. Common problems or malfunctions of the pitch blade control hydraulic actuators leads to the decline of boiler thermal efficiency and unexpected power plant trip. The inlet and outlet gas can be controlled by using the fan pitch blade control hydraulic actuator in order to regulate the internal pressure of the furnace and control the frequency in the power plant facility which utilizes soft coals as a power source.

  • PDF

Modelling of the effects of alkali-aggregate reaction in reinforced concrete structures

  • Pietruszczak, S.;Ushaksaraei, R.;Gocevski, V.
    • Computers and Concrete
    • /
    • v.12 no.5
    • /
    • pp.627-650
    • /
    • 2013
  • This paper deals with application of a non-linear continuum model for reinforced concrete affected by alkali-aggregate reaction (AAR) to analysis of some nuclear structures. The macroscopic behaviour of the material affected by AAR is described by incorporating a homogenization/averaging procedure. The formulation addresses the main stages of the deformation process, i.e., a homogeneous deformation mode as well as that involving localized deformation, associated with formation of macrocracks. The formulation is applied to examine the mechanical behaviour of some reinforced concrete structures in nuclear power facilities located in Quebec (Canada). First, a containment structure is analyzed subjected to 45 years of continuing AAR. Later, an inelastic analysis is carried out for the spent fuel pool taking into account the interaction with the adjacent jointed rock mass foundation. In the latter case, the structure is said to be subjected to continuing AAR that is followed by a seismic event.