• Title/Summary/Keyword: Power-feeding

Search Result 413, Processing Time 0.024 seconds

Factors Associated with Pressure to Eat as a Feeding Practice among Mothers with Infants (영아 어머니의 과도한 수유 관련 요인)

  • Ra, Jin Suk;Jeong, Yeon-Hee;Kim, Soon Ok
    • Child Health Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.277-285
    • /
    • 2020
  • Purpose: This study aimed to identify factors-both infant-related and maternal-associated with pressure to eat as a feeding practice among mothers with infants. Methods: This study used a cross-sectional design and included 163 mothers of infants aged 2~12 months. Of the 180 self-reported questionnaires that were distributed, 163 (91%) were included in the data analysis. Multiple regression analysis was used to identify the factors associated with pressure to eat as a feeding practice among the mothers. Results: Infant's temperament (β=-.17, p=.035), mother's body mass index (β=-.16, p=.048), and concern about the infant being underweight (β=.30, p=.001) were associated with pressure to eat as a feeding practice among mothers. The explanatory power of these variables in the predictive model was 19.2%. Conclusion: Educational programs should be developed for improving mother's awareness of cues from infants with difficult temperament. In addition, educational interventions regarding the correct evaluation of infant's weight are needed to relieve mother's concern about their infant's being underweight. These interventions might be helpful to reduce the prevalence of pressure to eat as a feeding practice among mothers with infants.

The Analysis of Trolley-Rail Short Circuit Current in a Single Track AT Feeding System (단선 AT 급전계통의 전차선-레일 단락 고장전류 분석)

  • Cho, Gyu-Jung;Ryu, Kyu-Sang;Lee, Hun-Do;Heo, Seung-Hun;Kim, Chul-Hwan;Kwon, Sung-Il;Kim, Cheol-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1659-1665
    • /
    • 2015
  • In general, AT(Auto-transformer) is used to improve voltage sag and inductive interference in power lines and communication lines in AC electrical railway feeding system. Especially, Korean AT feeding system has different composition compared to other countries like Japan or France, so that it has some special characteristics. However, relays imported from other countries have been used in Korea, and settings of these relays should be modified and reflect distinct characteristics of Korean AT feeding system. Therefore, study about fault analysis based on modeled AT feeding system is important. In this paper, we modeled a single track AT feeding system by using PSCAD and analyzed fault current flow in case of trolley-rail short circuit fault. Finally, we presented current magnitude of each branch expressed by boosting current of AT.

Cracking Susceptibility of Laser Cladding Process with Co-Based Metal Matrix Composite Powders (레이저 클래딩 공정 조건이 코발트 합금-텅스텐 카바이드 혼합 코팅층의 균열 발생에 미치는 영향)

  • Lee, Changmin;Park, Hyungkwon;Lee, Changhee
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.41-46
    • /
    • 2014
  • In this study, cracking susceptibility of laser cladding was investigated according to the processing parameters such as laser power, scan speed and feeding rate with blended powders of stellite#6 and technolase40s (WC+NiCr). The solidification microstructure of clad was composed of Co-based dendrite structures with ${\gamma}+Cr7C3$ eutectic phases at the dendritic boundaries. The crack propagation showed transgranular fracture along dendritic boundaries due to brittle chrome carbide at the eutectic phases. From results of fractography experiments, the fracture surface was typical cleavage brittle fracture in the clad and substrate. The number of clad cracks, caused by a tensile stress after the solidification, increased with increase of laser power, scan speed and feeding rate. Increase of the laser power caused large pores by facilitating WC decarburizing reaction. And the pores affected increase of crack susceptibility. High scan speed caused increment of clad cracks due to thermal stress and WC particle fractures. Also, increase of the feeding rate accompanied an amount of WC particles causing crack initiation and decarburizing reaction.

Analysis of Tram Feeding System according to Train Diagram Change (열차운행 시격 변경에 따른 트램 급전계통 해석)

  • Kim, Dong-Man;Chang, Chin-Young;Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.634-639
    • /
    • 2015
  • In order to understand phenomenon of the electric railway power feeding system in the construction planning step, analysis of the overall system including electric characteristic of electric railway power feeding system, train running characteristic and power consumption pattern and train operation plan and gradients of railroad and curve radius is required. This paper study the feeder system by analysis of comprehensive system according to train operation plans, line impedance, running characteristic of train, electrical properties of the feeder system. In order to understand phenomenon to the feeder system of tram exactly regarding export of the field railroad preceeding actively recently.

A Compact Feeding Structure for an Wide-band Array Antenna using a Microstrip Metamatreial UWB Power Divider (메타재질구조의 UWB 전력 분배기를 이용한 광대역 배열 안테나를 위한 급전부 설계)

  • Eom, Da-Jeong;Kahng, Sung-Tek;Park, Jeong-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1159-1163
    • /
    • 2012
  • In this paper, a new method is suggested to reduce the size of a wide-band array antenna. The power-divider for the feeding structure is made compact as ${\lambda}/8$ with the help of a novel Metamaterial UWB bandpass filter. This power divider is clearly different from others in that the proposed design uses microstrip structured Composite Right and Left-Handed (CRLH) filters, while others use two dielectric layers or long tapered transmission lines. In order to validate the proposed design method, the circuit and full-wave simulated results of the power divider with the Metamaterial UWB filters are compared to each other, and the Metamaterial properties of the structure are shown with the electric field at the ZOR and dispersion diagram. Furthermore, the antenna performance of the fabricated antenna with the power divider is measured and compared with the prediction. Also, the size reduction effect by the proposed scheme is addressed.

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

Manufacture of Real-time Power Simulator for Electric Railway (전기철도용 실시각 급전시뮬레이터 제작)

  • Jang, Dong-Uk;Chung, Sang-Gi;Kim, Hyol-Chul
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1473-1479
    • /
    • 2009
  • Recently, the high speed train was operated and then the train system's reliability requirements are growing more and more. The exact prediction simulation is necessary in the design of power feeding system by the increase of railway electrification. In order to develope the AC feeding system analysis technology, real-time power simulator was manufactured. It is composed to eight channels analog input, forty channels analog output and forty-eight channels digital I/O. The size of simulator rack is 19" and the two I/O boards are installed the PXI chassis built into the real time os. The signal I/O is possible through BNC connector. The test results of manufactured simulator are obtained that the error range of analog I/O signal is below 1 % and simulation condition is set to 1 ms and the simulation output of the analog output compares the results of the simulator.

  • PDF

A Study on the Leading Phase Operation of Single Phase PWM Converter Train (단상PWM컨버터 차량의 진상운전에 관한 연구)

  • Kim, Baik
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.357-363
    • /
    • 2012
  • This paper presents a new operation method for the single phase PWM(Pulse Width Modulation) converter train. Recently, the trains adopting the PWM converter have become the majority in the electric locomotives since there are distinct advantages over the predecessors, which can be operated at near unity power factor. However, a slight modification of the control scheme makes this kind of vehicles run in the region of leading power factor. Although this feature seems to be of no significant use by itself, the leading phase operation can improve the voltage profile and the line loss of the feeding systems is decreased by compensating the reactive power loss along the line when it considered together with the feeding systems. This method is even more economical and efficient comparing with the installation of SVC that is mainly used for this purpose since the train can become a movable compensator. With the conditions and some essential formula for the leading phase operation, a new power factor control algorithm has been proposed to implement this scheme. The results of simulation through SIMULINK model show that the proposed method is suitable enough for practical use.

Electromagnetic Induction Voltage according to the Position of Telecommunication Line from the Power Feeding Plant of Electrified Railway System (전기철도의 급전소 위치 관계에 따른 통신선 전자유도 전압)

  • Lee, Sangmu;Choi, Munhwan;Cho, Pyung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.689-692
    • /
    • 2015
  • That induced voltage by an electrified railway line is related with the position of telecommunication line between traction power feeding systems is practically varified by measurements in the real field. This experimented fact is conformed with the calculated simulation provided by the ITU-T Directives concerning the protection of telecommunication lines against harmful effects from electric power and electrified railway lines. Therefore it is needed to consider at what position a telecommunication line is parallelized with power feeding line of traction system when an induction phenomenon is evaluated or measurement is carried out besides the length of parallelization and the separate distance between power line and telecommunication line.

  • PDF

Compensation of Voltage Drop Using the TSC-SVC in Electric Railway Power Supply System (전기철도 AT 급전시스템에서의 TSC-SVC를 이용한 전압강하 보상)

  • 정현수;방성원;김진오
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.29-36
    • /
    • 2002
  • Recently, power quality problems in AC high-Speed Railway system have been raised, because heavy train and its higher speed are required in addition to new control system by using the Electronic devices. The installation/operation of the Series Capacitor(SC) has been only a device far voltage drop in power system up to now. However, the sufficient effectiveness of compensating In voltage drop has not been proved yet because of technical limitationf SC, and harmonic resonance is attracting a attention as one of new issues. Several problems are expected such as vocational problems of a traction substation, and overloading caused by a new construction of electric railway and the in transport. Therefore, extension of power feeding the fault in the traction substation should be also considered. So this paper represents the application of TSC-SVC on the electric railway power feeding system as a device of voltage compensation, and the simulations are executed through PSCAD/EMTDC.