• 제목/요약/키워드: Power-feeding

검색결과 413건 처리시간 0.033초

2차 보간법을 이용한 전기철도 급전계통의 고장점 산출 기법에 관한 연구 (A Study on Estimation Technique for Fault Location using Quadratic Interpolation in a Parallel Feeding AC Traction System)

  • 민명환;안태풍;권성일;정호성
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.599-604
    • /
    • 2017
  • Nowadays reactance method is being used as a technique for fault location in parallel feeding AC traction power system. However, implementation of this method requires a large number of field tests(ground fault) which is a huge burden on the operators. This paper presents a new estimation technique using quadratic interpolation to reduce number of times for field test and improves the accuracy of fault location. To verify a new technique, we solve AT feeding circuit and model it using PSCAD/EMTDC. Finally this paper conducts a comparative analysis of usefulness between a new technique and real field data.

CNC 와이어 성형기의 피딩박스 구동장치 개발 (Development of Power Train for Feeding Box of CNC Wire Forming Machine)

  • 조현덕
    • 한국공작기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.50-56
    • /
    • 2007
  • Wire forming machine is widely used in industries to make a variety of wire products such as coil springs and links. Along with the rapid development of CNC technologies, the usage of wire forming machine varies from single-purpose machinery to universal CNC machinery. Rotating the wires while feeding them simultaneously, we can improve the performance of the machines with aspects of efficient tooling and complicated geometric forming. In this study, a new gear train is developed for the control of both feeding and rotating wires independently at the same time. The developed mechanism has many benefits as following, making more complicated geometric and precision products, easier tooling, and simpler programming.

팬타그래프 전압제약조건을 고려한 AT급전계통 해석 (Analysis Of AT Feeding Systems Considering The Voltage Constraint Conditions Of The Pantagraph)

  • 문영현;김백
    • 한국철도학회논문집
    • /
    • 제9권6호
    • /
    • pp.652-656
    • /
    • 2006
  • Constant load model is widely used for an electric train to perform the static analysis of AT (Auto Transformer) feeding systems. In this model, the train will be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. However there must be some constraints imposed on the pantagraph voltage in actual operations. These constraints are established for the reason of protecting the feeding facilities from excessive rise of regenerative braking voltage or guaranteeing the minimum traction power of train. In normal operating situation, the pantagraph voltage of the train should be maintained within these limits. Keeping these facts in minds, we suggest new methods or analyzing AT feeding systems using the constant power models with the conditions of voltage constraints. The simulation results from a sample system using the proposed method illustrate both the states of system variables and the supply-demand relation of power among the trains and the systems very clearly, so it is believed that the proposed method yields more accurate results than conventional methods do. The proposed methods are believed to contribute to the assessment of TCR-TSC for compensating reactive powers too.

A Study on a Catenary Impedance Estimation Technique using Boosting Current Compensation Based on Current Division Characteristics of an AT Feeding System

  • Jung, Hosung;Kim, Hyungchul;Chang, Sang-Hoon;Kim, Joorak;Min, Myung-Hwan;An, Tae-Pung;Kwon, Sung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1370-1376
    • /
    • 2015
  • Generally, an autotransformer(AT) feeding system consists of double tracks, up and down, with the trolley wire and feeder wire of the up and down tracks connected in the sectioning post(SP). Consequently, load current or fault current flows on two tracks based on catenary impedance characteristics, making it difficult to estimate catenary impedance accurately. This paper presents a technique for the estimation of catenary impedance using boosting current compensation based on the current division characteristics of an AT feeding system to improve the operation performance of impedance relay. To verify the technique, we model an AT feeding system through a power analysis program (PSCAD/EMTDC) and simulate various operation and fault conditions. Through the simulation, we confirmed that the proposed technique has estimated catenary impedance with a similar degree of accuracy to the actual catenary impedance

고속 전철구간에서의 전력유도 환경 영향 분석 (Environmental Effect Analysis of Electromagnetic Induction in Express Electric Railway)

  • 이상무;최문환;조평동
    • 정보통신설비학회논문지
    • /
    • 제9권1호
    • /
    • pp.19-23
    • /
    • 2010
  • The Electromagnetic Interference could occur due to power line on the telecommunication service. The Countermeasure is practised by legal law. Various affecting factors are described in the law. In this paper, an effect by pipeline especially in the ground, power feeding plant, and curved railway sector is analyzed as environmental factors which are not included in the law. By the practical measurement, it appears that the measured voltages on the spots with underground pipeline are grouped into lower voltage level, induced voltage tends to be high near power feeding plant, and also in the curved railway line. These analytical results can be meaningly considered in the application of countermeasure.

  • PDF

고속전철 급전계통에서의 고조파 측정 방안 (Scheme for Harmonics measurement in feeding System of high speed railroad)

  • 최흥관;황치우;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.304-307
    • /
    • 1998
  • High speed railway is under construction from Seoul to Pusan. A traveling train is large single phase load that consumes 14MW power in feeding system of high speed railroad. In this paper, measurement scheme and method of power system harmonics which are generated from those loads in railroad supply system are described. This measurement scheme will be used as a first step to pave a way to power quality management due to harmonic distortion by the highspeed rail way.

  • PDF

경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (I) (Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (I))

  • 김주락;이장무;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1432-1438
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

교류전기철도 병렬급전 운영을 위한 위상조정장치 제어기법 (A Control Method of Phase Angle Regulator for Parallel-Feeding Operation of AC Traction Power Supply System)

  • 이병복;최규형
    • 한국산학기술학회논문지
    • /
    • 제21권5호
    • /
    • pp.672-678
    • /
    • 2020
  • 교류전기철도 급전시스템에 병렬급전방식을 적용할 경우, 전동차 부하로 인한 전압강하 및 최대순시부하를 감소시켜 급전구간을 연장하고 급전용량을 향상시킬 수 있다는 장점이 있다. 그러나 변전소 간에 위상차가 있을 경우 순환전력이 발생하기 때문에 적용이 제한되며, 전동차 운행에 따른 부하 분포에 따라 변전소 부하 불균형이 커져서 급전용량이 저하되는 문제점이 있다. 본 논문에서는 변전소 위상차 및 전동차 부하분포에 따라 변동하는 순환전력을 실시간 제어하고 변전소 부하 불균형을 해소하기 위하여 사이리스터 제어 위상조정장치 (TCPAR: Thyristor Controlled Phase Angle Regulator, 이하 TCPAR)를 적용하는 방식을 제안하고, 이를 구현하기 위한 검토를 수행하였다. 전기철도 급전 시스템에 TCPAR을 적용하기 위한 제어 기법으로서, 변전소 공급전력을 입력으로 이용하여 변전소 위상차 및 전동차 부하 분포에 따라 변동하는 순환전력과 변전소 부하 불균형을 효과적으로 억제하는 제어모델을 제시하였다. PSCAD/EMTDC를 이용한 시뮬레이션 결과, 전기철도 병렬급전에 제안한 TCPAR을 적용함으로써 변전소 위상차 및 전동차 부하분포에 따라 변동하는 순환전력 및 변전소 부하 불균형을 효과적으로 억제시킬 수 있다는 것을 확인하였다. 제안 기법을 전기철도 병렬급전에 적용할 경우, 병렬급전 적용 범위를 확대하고 급전용량을 증가시킬 수 있을 것으로 기대된다.

스펙트럼 해석에 의한 자탈형 콤바인의 진동 특성 고찰 (A Study on the Vibration Characteristics of a Head-Feeding Combine by Spectral Analysis)

  • 최중섭
    • Journal of Biosystems Engineering
    • /
    • 제26권1호
    • /
    • pp.11-20
    • /
    • 2001
  • Experiments under the stationary and harvesting condition, were performed in order to investigate the vibration characteristics of a head-feeding combine. 6 degrees of freedom components of acceleration at the location of the center of the gravity, and 3 degrees of freedom components of acceleration at the location of the operator seat were measured independently. The vibration characteristics of the combine were estimated with the power spectral density of the time series data of accelerations. From this research, the following results were obtained. 1. Vibration of a head-feeding combine under the stationary condition(engine, thresher and cutter are driven without harvesting) is mainly influenced by the engine. Further, 1/3, 1/2 (sub-harmonic) frequency components of the engine are observed besides engine driving frequency component(45Hz). 2. Vibration of a head-feeding combine under the harvesting condition is influenced by the engine, threshing unit and driving unit. Namely, some kinds of vibration frequency components in harvesting are observed compared with stationary condition. Further, sub-harmonic frequency components of the engine are observed besides engine driving frequency component as same as stationary condition. From these results, it may be concluded that vibration of a head-feeding combine is characteristics of semi-periodic and nonlinear vibration.

  • PDF

변전소와 차량간의 동기화를 통한 실시간 전차선로 임피던스 예측 기법 연구 (A Study on Real Time Catenary Impedance Estimation Technique using the Synchronized Measuring Data between Substation and Train)

  • 정호성
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1458-1464
    • /
    • 2013
  • This paper proposed a new real time catenary impedance estimation technique using synchronized power data from the measured data of operating vehicle and substation for catenary protective relay and fault locator setting. This paper presented estimation equation of catenary impedance using synchronized power data between substation and vehicle of AT feeding system for the performance verification of the proposed technique. Also AC feeding system is modeled through power analysis program and performance was verified through simulation according to various load changes. We verified that average 2.38%(distance equivalent 23.8 m) error appeared between the proposed estimation equation of catenary impedance and power analysis program simulation output in no connection double track system between up track and down track. Furthermore, We confirmed that estimation error is bigger depending on the increasing the distance from substation and vehicle impedance using only using vehicle current when calculating vehicle impedance in connection double track system between up track and down track. But, We confirmed that the proposed technique estimated accurately catenary impedance regardless of vehicle impedance and distance from substation.