• Title/Summary/Keyword: Power-bus

Search Result 1,399, Processing Time 0.024 seconds

Variance of waiting time in the priority scheme of token bus protocols (토큰버스 프로토콜의 우선순위기능에서 대시시간의 분산)

  • Hong, Seung-Ho
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.5
    • /
    • pp.42-53
    • /
    • 1995
  • Token bus protocols have been sidely accepted for Medium Access Control (MAC) in real-time networks such as those used in factory automation, distributed process control, nuclear power plant, aircraft and spacecraft. Token bus protocols provide timer-controlled priority mechanism, which offers multiple level of privilege of medium access to different type of traffic. This paper presents and approximate analytical model for the evaluation of variance of waiting time in the time-controlled proiority scheme of token bus protocols. Token bus system is assumed to be operated with singe-service discipline which is the practical case of real-time networks such as those used in distributed process control and factory automations. The approximate analytical model is validated by comparison with the simulation resuls.

  • PDF

The Calculation of Unbalanced Voltage on the tertiary bus of a single phase auto transformer in case of Parallel Operation with Different Manufacturer (제작소가 상이한 단상 주변압기 병행 운전시 불평형전압의 검토)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Joe, S.H.;Hur, Y.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.458-460
    • /
    • 2001
  • This paper described the unbalanced voltage on the tertiary bus of a single Phase auto transformer in the case of parallel operation with different manufacturer at each Phase. The unbalanced capacitances between primary to secondary winding, secondary to tertiary winding and primary to tertiary winding makes unbalanced bus voltage in the tertiary bus side. The unbalanced voltage let the surge arrester to operate in the power frequency range, and it causes the arrester to burn out. The failure of the arrester at one phase makes line to ground fault, which lead to the surge arrester failure of the other two phase on the tertiary bus.

  • PDF

Development of Bus Load Forecasting System based on Windows95 : Part I (윈도우즈95에 기초한 모선수요예측시스템의 개발(I))

  • Jeon, Dong-Hoon;Song, Seok-Ha;Lim, Joo-Il;Hwang, Kab-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.169-171
    • /
    • 1996
  • In this paper, we have developed bus load forecasting system (BUSLOF) based on Windows 95. It has been developed for the secure operation of electric power system. It forecasts regional load and bus load using regional distribution factor(RDF) and bus distribution factor (BDF) which are calculated from bus load in the past. It is equipped with graphic user interface(GUI) which enables a user to easily access to the system. The performance of the developed system is estimated in sample data.

  • PDF

A Power System Economic Operation using Bus Distributed Transmission Loss Information (분산 송전손실정보에 의한 전력시스템의 경제운용)

  • 이봉용;심건보
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.4
    • /
    • pp.333-340
    • /
    • 1990
  • 분산 송전송실정보에 의한 전력시스템의 경제운용=The transmission loss information produced in a line may be shared by both end buses connected to the line. Then, the loss may be seen as if it is discretely produced at both buses. Likewise, all transmission losses can be considered as if they are discretely produced at every bus distributed. The bus transmission loss equation can be defined, in which the loss information about connected lines are contained. This formulation can greatly enhance the computational efficiency for the economic control of both real powers and voltages. It requires solutions of two linear matrix equations, one for the calculation of incremental transmission losses and the other for the determination of voltage levels to be controlled. The Proposed approach is demonstrated through three sample systems and it is found that the solutions can be obtained after three iterations regardless of system sizes. This implies that only one-step search would be required for the solution if real informations would be available. Results are compared with those of optimal power flows.

  • PDF

Design and Fabrication of Light-Weight Composit Bus Bar (복합경량 부스바의 설계 및 제작)

  • Bae Joon-Han;Bea Duck-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.334-340
    • /
    • 2006
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the 'skin' of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum. The optimum extruding ratio was 16 at $300^{\circ}C$. The electrical resistance of manufactured composite bus bar was $57{\mu}{\Omega}$ at DC and $49.5{\mu}\{Omega}$ at 300Hz.

Development Of Small Signal Stablility Linear Analysis Program for Large Scale Power System. (대규모 전력계통의 미소신호 안정도 해석을 위한 선형해석 프로그램 개발)

  • Song, Sung-Geun;Nam, Ha-Kon;Shim, Kwan-Shik;Kim, Yong-Gu;Kim, Dong-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1054-1056
    • /
    • 1999
  • It is the most important in small signal stability analysis of large scale Power systems to compute only the dominant eigenvalues selectively with numerical stability and efficiency. In this Paper evoluted linear analysis program, transformed state matrix using Inverse transformation with complex shift and then Hessenberg process and iterative scheme are used to accelerate Hessenberg process, can calculate dominant eigenvalues. In this Paper, The accuracy of this Program has been validated against 4-machines 11-bus system and New England 10-machines 39-bus system. Also applied to KEPCO system - about 791-bus 250-machines 2500-branches, got 2568 order state matrix, and calculated two dominant modes. This analysis result equaled to result of EPRI's SSSP program to use commonly, and calculating time is faster.

  • PDF

Substation Bus Voltage Angle Calculation Method Using Voltage Angle Difference Measured at the Tie Switch in the Distribution Line (배전선로 상시연계점 측정 전압 위상차를 이용한 변전소 모선 위상각 추정 방법)

  • Son, Ju-Hwan;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • Distribution networks are operated in radial fashion during the normal state. Loop configuration is also required temporally in case of live load transfer among the adjacent feeders. Voltage angles of each substation buses are very important data in order to calculate power flow of the loop structured distribution feeders. This paper proposes substation bus voltage angle calculation method using voltage angle difference measured at the normally open tie switches. Simulation case studies using Matlab simulink have been performed to establish feasibility of proposed method.

Control simulation of MR damper for a cruise bus including the virtual dynamic damper (가상 동흡진기를 고려한 우등버스용 MR댐퍼의 제어 시뮬레이션)

  • Park, S.J.;Sohn, J.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.19-24
    • /
    • 2011
  • In this study, a control method of MR(magneto-rheological) damper for a cruise bus is investigated. A virtual dynamic damper and a sky-hook algorithm are employed to control the damping characteristics of MR damper. Coefficients for a virtual dynamic damper are determined through the parameter identification. A quarter car model of a cruise bus is established by using ADAMS/Car program for the computer simulation. Sine wave excitation and random excitation are used to compare the controlled MR damper with the passive damper. From the simulation results, the performance of MR damper with a virtual dynamic damper is better than that of the passive damper.

Simulator for Monitoring the Operations of Range Extender Electric Vehicles

  • Chun, Tae-Won;Tran, Quang-Vinh;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.424-429
    • /
    • 2011
  • In this paper, the simulator of an on-line monitoring system for the range extender electric vehicle has been developed. The messages from the four control modules, the air pressure and fuel level sensors data, and the on/off switching states of 31 indicator lamps can be received through the control area network (CAN), and displayed on the graphic panel. The simulator was designed using the four DSP boards, variable resistors, and toggle switches instead of the four control modules, sensors, and switching state of indicator lamps on an actual series hybrid electric vehicle (SHEV) bus, respectively. The performance of the monitoring technologies was verified with the simulator at the laboratory, and then it was tested on an actual SHEV bus. The simulator is very useful at the initial development of the monitoring system at the hybrid-type or electrical vehicles.

A Study on Calculation and Decomposition of Bus Incremental Cost on Power System Operation (계통운전상태에서의 모선증분비용 산정 및 분해에 관한 연구)

  • Kim, Y.H.;Lee, Buhm;Choi, S.K.;Moon, H.K;Lee, J.G.;Yeon, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.105-107
    • /
    • 2002
  • This paper provides calculation and decomposition of Bus Incremental Cost on Power System Operation. In this method we show deriving Shadow Price from state variables in Optimal condition. And the decomposition can give a detailed description of each Bus Incremental Cost. The proposed method is applied to IEEE-30 and results shows the effectiveness of the method.

  • PDF