• Title/Summary/Keyword: Power-Operated-Valve

Search Result 105, Processing Time 0.021 seconds

A Development of Proportional Control Solenoid Valve Performance Tester for Automatic Transmission (자동변속기용 비례제어 솔레노이드밸브 성능시험기 개발)

  • Lee, G.H.;Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • The proportional control solenoid valves as well as the PWM solenoid valves operated by electric signal play an important role in the hydraulic system for automatic transmissions to improve the shift quality. However it is not generally available for the performance data because most of the automotive parts manufacturer don't release the specific test results, especially dynamic performance that is essential to design a shift control algorithm. In this research, a performance test equipment that can be applied to various types of pressure control solenoid valve was developed. It was implemented by 8-bit micro-controller with many useful functions such as adjustable PWM carrier frequency, embedded function generator, current controller, data monitoring and acquisitions, etc. for the test of dynamic performance of solenoid valve as well as the steady-state pressure characteristics. The performance test results for the direct type proportional control solenoid valve show not only the validity of overall functions but also its usefulness as a hydraulic valve tester.

  • PDF

A Study on Design of Notches in Valve Plate of Swash Plate Type Axial Piston Pumps Operated Bi-directionally (양방향 구동 사판식 액시얼 피스톤 펌프의 밸브 플레이트 노치 설계에 관한 연구)

  • Choi, Sae Ryung;Lee, Ill Yeong;Han, Sung Min;Shin, Jung Woo
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.39-46
    • /
    • 2016
  • Flow and pressure ripple in swash plate type piston pumps is largely dependent on the design of notches(silencing grooves) in the valve plate. In uni-directional pumps, the basic design concept for notches in the valve plate could be said to be established. It is easily deduced that the design concept for notches in uni-directional pumps can not be simply applied to bi-directional pumps requested for EHA(electric hydrostatic actuators). To carry out systematic research on technological issues regarding notch applications to bi-directional piston pumps, five notch designs are devised. The effects of the notch designs on the characteristics of the pump are investigated by numerical simulations and experiments. Through this study, basic concepts about notch design for bi-directional piston pumps are suggested.

Development and Verification of Analytical Model of a Pilot Operated Flow Control Valve for 21-ton Electric Excavator (21톤급 전기 굴삭기용 파일럿 작동식 유량제어 밸브의 해석모델 개발 및 검증)

  • Kim, D.M.;Nam, Y.Y.;Seo, J.H.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.12 no.3
    • /
    • pp.52-59
    • /
    • 2015
  • An electro hydraulic poppet valve (EHPV) and a variable orifice poppet are assembled in a single block, which is referred to as a RHINO but is also generally called a pilot-operated flow control valve. In this study, we analyzed the structure and the operating principle for a RHINO applied in a 21-ton electric excavator system. The RHINO was experimentally tested to measure the dynamic responses and the pressure energy loss. In this test, we investigated the variation in the conductance coefficient according to the increase in the supply pressure under a constant current and a variation in the flow rate according to the increase in the current. Then, the geometrical shapes and the spring stiffness of the RHINO were considered to develop an analysis model. The characteristics (current-force and hysteresis) for the solenoid based on the experimental data were reflected in the analysis model that was developed, and the reliability of the analysis model was also verified by comparing the experimental and analytical results. The developed model is thus considered to be reliable for use in a wide range of applications, including optimum design, sensitivity analysis, parameter tuning, etc.

The characteristics in flow type of helical trim to unclear valve (원자력 밸브용 헬리컬트림의 유동 타입에 따른 특성)

  • Lee, Deok-Gu;Kim, Young-Bum;Yoon, In-Sik;Hwang, Ji-Hyuck;Kwon, Gap-Ju
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3074-3079
    • /
    • 2007
  • The conventional control valves have been used at the locations occurring high differential pressure and high temperature which causes cavitation, flashing, severe vibration due to abrupt flow change, and sudden pressure drop. Previous studies concerning control valves focused to prevent damage of valve trim due to the internal leak and low flow rate. The newly designed helical trim of control valve has been installed at the location of high pressure change and high temperature in a power plant, and operated for evaluation. It is confirmed that the new control valve developed in this study generates flow characteristics in comparison with previous helical trim of control valves.

  • PDF

Design of Optimal Capacity Coefficients of Flow Control Valves in the Hoist Hydraulic System Using the Complex Method (콤플렉스법에 의한 호이스트 유압회로 유량제어밸브의 최적유량계수 설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, two pilot operated check valves, two flow control valves. The capacity coefficients of flow control valves should be adjusted for the hoist to operate at moderate speed and minimize the hydraulic energy loss. However, it is difficult to adjust the four capacity coefficients of flow control valves by trial and error for optimal operation. The steady state model of the hoist hydraulic system is derived and the optimal capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Electromagnetic Analysis on the Torque Motor of Servo Valve for the Fuel Supply System of Auxiliary Power Unit (보조 동력 장치 연료 공급용 서보밸브의 토크모터 전자기 해석)

  • Chang, Se-Myong;Jang, Gang-Won;Jeong, Heon-Sul;Rhee, Dong-Ho
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • As a main part of an utility helicopter, the APU(Auxiliary Power Unit) has a solenoid valve system operated with a torque motor, which controls the flow rate in the fuel supply system. In this paper, we solved the Maxwell potential equations to analyze the electromagnetic force in the torque motor, and some additional analytic methods are used to compute the quantity of torque produced by the torque motor for the given circuit current. For the convenience, small displacement is assumed, and only magneto-static problem is considered for the two-dimensional cross section. The result will be compared with the three-dimensional analysis that will be studied in the near future.

  • PDF

Design and Performance Test of Valve Operated by ER Fluids (ER 유체로 작동되는 벨브의 제작 및 성능실험)

  • 장성철;염만오
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.1
    • /
    • pp.63-68
    • /
    • 2004
  • Recently ER fluids are put to practical use in fluid power industry field. As only with electrical signal change to the valve in which ER fluid flowing, ER fluid flow is controlled, so devepment of simple ER valves have been tried. In this case a technical problem is to check the pressure drop caused from flow rate change in valves because the pressure drop is very small. In this study ER valves are designed and manufactured, and small pressure drop induced from flow rate change is checked by pressure transducer which is made with appling strain gage. The ER valves and pressure drop check method are considered to be applied to the fluid power industry.

A Study of Earthquake Design Air Operated Valve Actuator in Nuclear Power Plant (원자력 발전소 AOV 구동기 내진 설계에 관한 연구)

  • Kim, Y.B.;Jang, H.;Yoon, I.S.;Kang, Y.M.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.485-490
    • /
    • 2008
  • Under localization developing for the control valve of the safety grade Q Class 1 which is established in the atomic power plant followed ASME Code and important parts (Body, Yoke, Bonnet, Actuator) design and produced. In order to verify this analyzed the earthquake stress of AOV. AOV the above of 33Hz occurred from fIrst mode, the earthquake stress occurred from inside the yield strength of the material.

  • PDF

Computer Simulation Study of the Hydrostatic Transmission Applied to the Rack-Bar Type Sluice Gate (래크바형 수문권양기에 적용된 정유압장치의 컴퓨터 시뮬레이션에 의한 작동특성 연구)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.2
    • /
    • pp.14-21
    • /
    • 2009
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, two counter balance valves, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations.

  • PDF

Development of UPFC GTO Thyristor Valve Test Equipment (UPFC GTO Thyristor VTE(Valve Test Equipment) 개발)

  • Kim, Soo-Yeol;Chang, Byung-Hoon;Yoon, Jong-Soo;Kim, Yong-Hak;Baek, Doo-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.391-395
    • /
    • 2008
  • KEPCO 80MVA UPFC has been operated in Gangjin Substation since May 2003. This UPFC is composed of 40MVA shunt inverter and 40MVA series inverter, and developed in technical cooperation between Hyosung and Siemens. KEPCO has tried to localize UPFC control technique after its installation and developed GTO Thyristor Valve Test Equipment for annual maintenance test. The development of this equipment make it possible to process GTO Thyristor module test automatically and manage historic data systematically, which could improve UPFC reliability.