• Title/Summary/Keyword: Power-Operated-Valve

Search Result 105, Processing Time 0.024 seconds

Development of Performance Evaluation Program for Air-Operated Valve (공기구동 밸브 성능평가 프로그램 개발)

  • Yang, Sang-Min;Park, Jong-Kun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.5
    • /
    • pp.400-405
    • /
    • 2008
  • Air-operated valve is one of principal valves that are used to control fluid flow in nuclear power plants. It is necessary to evaluate periodically the performance of the AOV(Air-Operated Valve) which is used for controlling flow and pressure in nuclear power plants. In this study, we developed the integrated program HAES including hardware system to evaluate the performance of AOV. HAES(HANVIT AOV Evaluation System) consists of many modules such as valve information, thrust and torque analysis, actuator analysis, weak analysis and margin analysis. We applied with the test valve and showed that results evaluated by HAES is similar to those offered in the plant.

Effect of Differential Pressure on the Performance of Motor Operated Flexible Wedge Gate Valve (차압이 모터구동 Flexible Wedge형 게이트밸브의 성능에 미치는 영향)

  • Kim, Dae-Woong;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.151-158
    • /
    • 2007
  • The mechanism of power transmission from motor torque to stem thrust and the operation characteristic of each stroke position are analyzed using the diagnostic signal, and effects of differential pressure on the performance of motor operated flexible wedge gate valve are investigated. Test facility consists of 76 mm motor operated valve(flexible wedge type), pump and pipe system. Static and dynamic test are performed separately, and two differential pressure conditions are applied in the dynamic test. To evaluate the performance of valve, test signals for the torque, thrust, current, voltage and stroke length are acquired by using UDS which is diagnosis device for motor operated valve, and each diagnostic signal is analyzed and compared. The characteristic of valve performance factors such as stem factor, rate of loading, valve factor, are evaluated, and these factors are found to be severely influenced by the fluid differential pressure.

A Development of Web-based Safety Evaluation System of Motor-Operated-Valve in Nuclear Power Plant (웹기반 원전 동력구동밸브 안정성 평가 시스템 개발)

  • Bae, J.H.;Lee, K.N.;Kim, W.M.;Park, S.K.;Lee, D.H.;Kim, J.C.;Hong, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.903-908
    • /
    • 2001
  • A web-based client/server program, MOVIDIK(Motor-Operated-Valve Integrated Database Information of KEPCO) has been developed to perform a design basis safety evaluation for a motor-operated-valve(MOV) in the nuclear power plant. The MOVIDIK consists of seven analysis modules and one administrative module. The analysis module calculates a differential pressure on the valve disk, thrust/torque acting at a valve stem, maximum allowable stress, thermal-overload-relay selection, voltage degradation, actuator output and margin. In addition, the administrative module manages user information, approval system and code information. MOVIDIK controls a huge amount of evaluation data and piles up the safety information of safety-related MOV. The MOVIDIK will improve the efficiency of safety evaluation work and standardize the analysis process for the MOV.

  • PDF

Performance Analysis of Air Operated Valve by Thermal Aging (공기구동밸브의 열노화에 따른 성능평가)

  • Lee, Sun-Ki
    • Journal of Power System Engineering
    • /
    • v.19 no.5
    • /
    • pp.93-98
    • /
    • 2015
  • Nuclear power plants has a number of valves, which are operating at a high temperature-high pressure and radiation environment conditions. Nevertheless, it is important to maintain the reliability of the valves to ensure safe operation of the nuclear power plant. However, the aging of the valves by increasing of years of plant operation and the system transients due to the sudden load change are working the failures of the reliability of the valve. In this paper, we evaluate experimentally the performance change according to the thermal aging of the valve. Results show that the valve stem and the actuator leakages were enlarged by the thermal aging.

A Experimental Study to Diagnose of Air Operated Valve (공기구동 밸브 진단을 위한 동적특성의 실험적 고찰)

  • Yang S.M.;Hong S.D.;Song D.S.;Park J.K.;Shin S.K.;Lee H.Y.;Yang S.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1766-1769
    • /
    • 2005
  • Air-operated valve(AOV) is one of principal valves that are using to control fluid flow in nuclear power plants. AOV is suffered from damage and malfunction by the abrasion, corrosion and vibration of valve parts under the long time operation. This mechanical trouble and malfunction of valve is critical for the safety of power plant. So a periodic diagnosis for safety of power plants is inevitable to guarantee the safety of the power plant. But depending on the type of the actuator and valve body, various types of AOV exist. In this study, It is developed the diagnostic system that users of power plants are easy to handle in this paper.

  • PDF

Procedure and Method of Equipment Qualification for Solenoid-Operated Valves Used in Nuclear Power Plants (원전용 솔레노이드 밸브의 기기검증 절차 및 방법)

  • Lim, Byung-Ju;Park, Chang-Dae;Chung, Kyung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.683-691
    • /
    • 2011
  • In order to develop technology for an equipment qualification (EQ) test, which is an important process in localizing solenoid-operated valves used in nuclear power plants, we analyzed related regulations, test procedures, conditions, equipment, and acceptance criteria. EQ regulations for the solenoid-operated valve are classified as law, guide, and standard, and are subdivided according to test specimens and contents. The EQ test is composed of functional, normal-, and accident- condition tests. The solenoid-operated valve is aged under normal and accident conditions, which are predicted in the design conditions of a nuclear power plant, and the performance of the valve is measured by a functional test. The test method and procedure analyzed in this paper might be very useful for manufacturers as well as EQ testers.

Development of Diagnosis System for Diaphragm Operated Globe Valve (다이어프램 구동형 글로브 밸브의 진단장비 개발)

  • Yang, Sang-Min;Shin, Sung-Ky
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.975-980
    • /
    • 2007
  • Air-operated valve is one of principal valves that are used to control fluid flow in nuclear power plants. A periodic diagnosis for the safety of power plants is necessary. But there are many difficulties such as economic loss caused by income of high cost devices and a matter hard to deal with users. In this study, we developed the diagnostic system that users of power plants are easy to handle. The diagnostic system is composed of database module, diagnosis test module and analysis module.

Development on the Structural Analysis Code of the Air-Operated Valve (공기구동 밸브의 구조해석 코드개발)

  • Lee Hyun-Seung;Lee Young-Shin;Cho Taik-Dong;Ko Sung-Ho;Shin Sung-Ky;Lee Ho-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.575-580
    • /
    • 2006
  • Air-operated valves are extensively used for process control and system isolation functions in nuclear power plant, where the safety is primary issue. The purpose of this study is to develop structural analysis code of various air-operated valves such as globe valve, gate valve, and butterfly valve. The thrust formula is derived for valve with the expected weak areas. The expected weak areas are referred from EPRI data. The structural stress analysis is carried out by analytical and commercial FEM code, ANSYS 8.0. The numerical results are compared together and verified on program procedures.

  • PDF

MOTOR CONTROL CENTER (MCC) BASED TECHNOLOGY STUDY FOR SAFETY-RELATED MOTOR OPERATED VALVES

  • Kang, Shin-Cheul;Park, Sung-Keun;Lee, Do-Hwan;Kim, Yang-Seok
    • Nuclear Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.155-162
    • /
    • 2006
  • It is necessary to monitor periodically the operability of safety-related motor-operated valves (MOVs) in nuclear power plants. However, acquiring diagnostic signals for MOVs is very difficult, and doing so requires an excessive amount of time, effort, and expenditure. This paper introduces an accurate and economical method to evaluate the performance of MOVs remotely. The technique to be utilized includes electrical measurements and signal processing to estimate the motor torque and the stem thrust, which have been cited as the two most effective parameters in diagnosing MOVs by the US Nuclear Regulatory Commission. The motor torque is calculated by using electrical signals, which can be measured in the motor control center (MCC). Some advantages of using the motor torque signature over other signatures are examined. The stem thrust is calculated considering the characteristics of the MOV and the estimated motor torque. The basic principle of estimating stem thrust is explained. The developed method is implemented in diagnostic equipment, namely, the Motor Operated Valve Intelligent Diagnostic System (MOVIDS), which is used to obtain the accuracy of and to validate the applicability of the developed method in nuclear power plants. Finally, the accuracy of the developed method is presented and some examples applied to field data are discussed.

A Study on the Diagnosis and Failure Mode of AOV Actuators (공기구동밸브 구동기의 고장진단에 관한 연구)

  • Jeong, Gyeong-Yeol;Kim, Byeong-Deok;O, Sang-Hun
    • 연구논문집
    • /
    • s.34
    • /
    • pp.47-58
    • /
    • 2004
  • Power plants rely on air operated valves for the proper operation of many plant system. Many significant problems arise in vital systems of power plants due to air operated valve failures. This paper deals with the diagnosis technique and data acquisition method of an AOV actuator peformance. We constructed AOV diagnosis system and performed some tests to find out whether an AOV actuator was properly designed.

  • PDF