• Title/Summary/Keyword: Power zone

Search Result 828, Processing Time 0.032 seconds

A Study on Deep Geothermal Energy and Potential of Geothermal Power Generation in Mongolia (몽골의 심부 지열에너지 자원과 지열발전에 관한 연구)

  • Hahn, Jeong-Sang;Yoon, Yun-Sang;Kiem, Young-Seek;Hahn, Chan;Park, Yu-Chul;Mok, Jong-Gu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.1-11
    • /
    • 2012
  • Mongolia has three(3) geothermal zones and eight(8) hydrogeothermal systems/regions that are, fold-fault platform/uplift zone, concave-largest subsidence zone, and mixed intermediate-transitional zone. Average temperature, heat flow, and geothermal gradient of hot springs in Arhangai located to fold-fault platform/uplift zone are $55.8^{\circ}C$, 60~110 mW/m2 and $35{\sim}50^{\circ}C/km$ respectively and those of Khentii situated in same zone are $80.5^{\circ}C$, 40~50 mW/m2, and $35{\sim}50^{\circ}C/km$ separately. Temperature of hydrothermal water at depth of 3,000 m is expected to be about $173{\sim}213^{\circ}C$ based on average geothermal gradient of $35{\sim}50^{\circ}C/km$. Among eight systems, Arhangai and Khentii located in A type hydrothermal system, Khovsgol in B type, Mongol Altai plateau in C type, and Over Arhangai in D type are the most feasible areas to develop geothermal power generation by Enhanced Geothermal System (EGS). Potential electric power generation by EGS is estimated about 2,760 kW at Tsenher, 1,752 kW at Tsagaan Sum, 2,928 kW at Khujir, 2,190 kW at Baga Shargaljuut, and 7,125 kW at Shargaljuut.

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

A Characteristics of the Multiple Repair Welding HAZs in a Low Alloy-Steel(2.25Cr-1.0Mo) (저 합금강재(2.25Cr-1.0Mo) 반복 보수용접 열영향부의 특성)

  • Lee, Chul-Ku;Ahn, Jong-Seok;Lee, Nam-Hyuck;Lee, Gil-Jae
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.50-55
    • /
    • 2008
  • A low alloy-steel(2.25Cr-1.0Mo) has been widely used for boiler piping, header and tubes in high temperature and pressure conditions of the thermal power plant. It is common knowledge that the repair welding is permitted two or three times by customary practice rule, but there is no regulation to limit the number of repair welding base on the study heat-affected zone(HAZ), which is the weakest zone when repair welding is under taken, by experiments about the metallographic degradation and mechanical properties. Therefore, this study aims to verify the reliability of 5 times repair welding through conducting the experimental observation in the mechanical and the metallographic change on HAZ varying repair welding times. In results of the experiments, it is concluded that the reliability was kept in HAZ even up to the fifth repairs.

Zone-based Power Control Mechanism of CDMA Forward Link for High-speed Wireless Data Services (고속 무선 데이터 서비스를 위한 CDMA 순방향 링크에서의 Zone-based 전력제어 방식)

  • 윤승윤;임재성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7B
    • /
    • pp.673-685
    • /
    • 2002
  • In this paper, we analyze the pros and cons of the fast power control to the forward link in the environments where mixed traffics of voice and data produce the transmitted/received power difference. We propose the Zone-based power control scheme that can improve the performance of the fast power control scheme in the viewpoint of the resource allocation. The proposed scheme is a mechanism that controls both the power and rate of non-realtime data traffics according to location distribution of the mobile stations. The scheme is based on the conventional fast power control scheme in the CDMA systems, and it adaptively controls the transmission rate of each data traffic. Zone-based rate control of data call brings about somewhat power margin to the call. As a result, the proposed scheme saves the power consumption of portables and reduces the amount of interference. With the proposed scheme, not only be extended the service coverage of high-rate traffic to the entire cell service coverage, but also the QoS of low-rate traffic can keep going through the service time, especially, in the situation that the amount of incoming interference is much larger. The experimental results show that the proposed scheme yields a improved performance compared with the conventional scheme in terms of the power consumption and traffic throughput of portables, especially, with the increasing number of high-rate data traffics.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

A Zone-Based Two-Level Routing with Power-Aware (ZTPA) for MANETs (MANET에서 Power-Aware를 고려한 2계층 Zone기반 라우팅 프로토콜(ZTPA))

  • Kim, So-Jung;Won, Soo-Seob;Park, Hae-Woong;Song, Joo-Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.1429-1432
    • /
    • 2004
  • MANET(Mobile Ad Hoc Network)이란 어떠한 기반 구조나 중앙의 관리없이 동적으로 임시 네트워크를 형성하는 무선 mobile node의 집합이다. 이 논문에서는 MANET에서 근원지 node가 목적지 node로의 route를 발견하기 위해 전체 네트워크를 대상으로 route request 패킷을 flooding 할 경우 결과적으로 네트워크의 성능을 저하시킨다는 점과 mobile node가 제한된 양의 power를 가지고 있다는 점에 초점을 맞추어 연구가 진행되었다. 다시 말해 이 논문에서 제안된 ZTPA 라우팅 프로토콜은 기존의 ZRP를 기본으로 서로 겹치지 않는 격자 모양의 zone으로 네트워크가 구성된다. 또한 proactive 라우팅이 이루어지는 IARP에서 route 설정시 현재 node에 남아있는 power를 고려한 CMMBCR 라우팅 프로토콜이 사용되며 이와 더불어 두 개의 임계치(SVSZ, FVSZ)를 사용함으로써 설정된 route의 수명을 연장하고 신뢰성 있는 데이터 전송이 가능하여 전체적인 네트워크의 성능 향상을 야기할 수 있다.

  • PDF

AOZDV(Ad Hoc On-demand Zone and Distance-Vector) : A Routing Protocol with Novel Zone Mechanism in Wireless Ad hoc Networks (무선 Ad hoc 망의 새로운 Zone 기법을 적용한 AOZDV(Ad Hoc On-demand Zone and Distance-Vector) 라우팅 프로토콜)

  • Kim Yong-Woo;Choi Sung-Jae;Lee Hong-Ki;Song Joo-Seok
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.4
    • /
    • pp.299-309
    • /
    • 2006
  • In Mobile ad hoc networks, AODV is one of the famous on-demand routing protocol, which use the routing tables in the nodes if possible, or Route Discovery Process (RDP) is triggered to find a new route. However increasing the traffic of RDP causes dropping of the network performance in the large size of ad hoc networks. In this paper, we propose a novel routing protocol, named as AOZDV (Ad hoc On-demand Zone and Distance-Vector Routing), which enhances the AODV protocol with zone routing. AOZDV creates a Zone with neighbor nodes of the source/destination using traffic and power information, and utilizes Destination-Vector Table for internal routing in the Zone. We show by simulations that AOZDV can reduce the occurrence rate of route fail and RDP caused by route fail compared to existing routing protocols such as DSR and AODV.

Effect of the Boost Pressure on Thermal Stratification on HCCI Engine Using Multi-Zone Modeling (Multi zone Modeling을 이용한 흡기관내의 과급이 온도성층화를 갖는 예혼합압축자기착화엔진에 미치는 영향에 관한 연구)

  • Kwon, O-Seok;Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.248-254
    • /
    • 2009
  • The HCCI engine is a next generation engine, with high efficiency and low emissions. The engine may be an alternative to SI and DI engines; however, a pressure rise rate is a major limitation for high load range and power reduction. Recently, we were able to reduce the pressure rise rate using thermal stratification. Nevertheless, this was insufficient to produce high power. In this study, the reduction of the pressure rise rate using thermal stratification was confirmed and the HCCI engine power was increased using the boost pressure. The rate and engine power were produced by CHEMKIN and modified SENKIN. As a result of increasing the boost pressure, a higher IMEP was attained while the pressure rise rate increased only slightly in the HCCI with thermal stratification.

A Survey and Analysis of Swim Zone Width and Beach Scale Factor for Gangwon Beaches (강원도 해수욕장의 유영폭 및 해빈단면 축척계수 조사 분석)

  • Lee Jung-Lyul;Kim In-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.241-250
    • /
    • 2006
  • In the present study, a beach survey such as sand sizes, swim zone widths, and slopes of swash zone has been accomplished for 39 beaches along the Gangwon coastline. The data analysis presents that the swim zone width has a strong correlation with the sand size, showing that the swim zone width is reversely proportional to the 1.1 power of a grain size. The profile factor A has been analyzed using the beach profile form of $h=Ay^{2/3}$, where A was resulted to be proportional to the 0.77 power of a gram size.

Preventing cascading failure of electric power protection systems in nuclear power plant

  • Moustafa, Moustafa Abdelrahman Mohamed Mohamed;Chang, Choong-koo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.121-130
    • /
    • 2021
  • Cascading failure is the main cause of large blackouts in electrical power systems; this paper analyzes a cascading failure in Hanbit nuclear power plant unit two (2) caused by a circuit breaker (CB) operation failure. This malfunction has been expanded to the loss of offsite power (LOOP). In this study, current practices are reviewed and then the methodologies of how to prevent cascading failures in protection power systems are introduced. An overview on the implementation of IEC61850 GOOSE messaging-based zone selective interlocking (ZSI) scheme as key solution is proposed. In consideration of ZSI blocking time, all influencing factors such as circuit breaker opening time, relay I/O response time and messages travelling time in the communication network should be taken into account. The purpose of this paper is to elaborate on the effect of cascading failure in NPP electrical power protection system and propose preventive actions for this failures. Finally, the expected advantages and challenges are elaborated.