• Title/Summary/Keyword: Power system under frequency protection

Search Result 31, Processing Time 0.028 seconds

Measurement and Analysis of Antenna Induced Voltage for Tactical Mobile Wireless Communication System under HEMP Environment (HEMP 상황 하 전술기동무선통신체계 안테나 유도전압 측정 및 분석)

  • Park, Kyoung-Je;Jeong, Kil-Soo;Kim, Jung-Sup;Park, Yong-Woo;Park, Jae-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.30 no.2
    • /
    • pp.33-40
    • /
    • 2021
  • The situation of high-altitude electromagnetic pulses (HEMP) arises from high-altitude nuclear explosions. The HEMP situation can be simulated through the threat level investigation (TLI). In this paper, the induced voltage according to the antenna type of the tactical mobile radio communication system was measured and analyzed by TLI. Under the influence of HEMP, electronic equipment can be paralyzed or damaged. HEMP protection filters are commercially available for power lines and signal lines. However, commercialization of HEMP filters for antennas is insufficient, and even some of them exist for lightning protection. In order to make an appropriate HEMP protection filter according to the frequency and type of the antenna, the induced voltage was measured and the maximum induced voltage was analyzed through extrapolation. It was found that the measured induced voltage decreased as the frequency increased, such as in the HF, VHF and UHF bands of the measurement results.

Load shedding case study of the refinery plant power system considering dynamic characteristic (정유공장 전력계통 동특성을 고려한 부하차단 적용 사례연구)

  • Lee, Kang-Wan;Lim, Joo-Il;Kim, Hyung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.61-65
    • /
    • 2000
  • This paper presents the load shedding case studies and recommendations of load shedding scheme For improving the reliability to suit the requirements of LG-Caltex refinery plant power sγstem. It is recommended for LG-Caltex to decrease the total generation for the economic dispatch. When the LG-Caltex refinery is isolated from KEPCO utility system, the proper load shedding scheme should be implemented since total generation in LG-Caltex refinery plant is less than the load demand. According to the studies carried out the logic-based load shedding is recommended as the main protection scheme, with the combination of the under-frequency relay load shedding.

  • PDF

A Design of Power System Stabilization of TCSC System for Power system Oscillation Damping (전력 시스템의 동요 억제를 위한 TCSC용 안정화 장치 설계)

  • 정형환;허동렬;왕용필;박희철;이동철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.104-112
    • /
    • 2002
  • In this paper, it is suggested that the selection method of parameter of Power System Stabilizer(PSS) with robustness in low frequency oscillation for Thyristor Controlled Series Capacitor(TCSC) using Geletic Algorithm(GA). A TCSC meddle consists of a stories capacitor and a parallel path with a thyristor valve and a series inductor. Also in in parallel, as is typical with series capacitor applications, is a metal-oxide varistor(MOV) for overvoltage protection. The proposed PSS parameters are optimized using GA in order to maintain optimal operation of TCSC which is expected to be applied in transmission system to achieve a number of benefits under the various operating conditions. In order to verify the robustness of the proposed method, we considered the dynamic response of angular velocity deviation and terminal voltage deviation under a power fluctuation and rotor angle variation.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

Investigation of ITU Radio Regulations Regarding KPS Service Band

  • Subin Lee;Kahee Han;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.177-184
    • /
    • 2023
  • In order to reserve frequency bands for stable operation of the Korean Positioning System (KPS), it must be demonstrated that the impact of interference caused by KPS on other services operating in the same bands is tolerable. The International Telecommunication Union (ITU) provides the radio regulations and a compatibility assessment methodology for the coexistence of different services in limited frequency resources. The purpose of this paper is to investigate the radio regulations regarding the compatibility issues between the KPS and other services sharing the same frequency bands. The results of the investigation show that the RNSS system can be operated in the L5-band under the condition that the Power Flux Density (PFD) and Aggregated Equivalent PFD (AEPFD) thresholds specified in the radio regulations are met. In addition, the ITU recommends that the interference-to-noise ratio (INR) protection criteria be met to prevent degradation of the performance of radar systems operating in the L2/L6-band. In the case of the S-band, coordination of allocations for RDSS space stations with respect to terrestrial services is not required if the PFD does not exceed regulated thresholds regulated by ITU.

A Development of the Digital Swithchgear using the Microprocessor (마이크로 프로세서를 이용한 전자식 배전반 개발)

  • Byun, Young-Bok;Joe, Ki-Youn;Koo, Heun-Hoi;Kim, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.375-379
    • /
    • 1990
  • A microprocessor-based multi-function switchgear for the protection, measurement and control of the power system is presented. For the extraction of the RMS values of the fundamental components of current and voltage signals, a simple digital filter based on cross-correlation of the distorted signal with even and odd heptagonal waves is used. The frequency response of this filter is almost identical to that of the filter based on the discrete fourier transform, while its computational requirement is far less. For the time delay element relaying, a new log-table based relaying algorithm is suggested. The suggested use of the heptagonal wave cross-correlation digital filter algorithm and a new relaying algorithm reduce the computational needs so drastically that all functions of the switchgear can be implemented on the microprocessor system. Real time testing of the implemented daboratory prototype show good practical response under different operating conditions.

  • PDF

Dedicated Cutback Control of a Wind Power Plant Based on the Ratio of Command Power to Available Power

  • Thapa, Khagendra;Yoon, Gihwan;Lee, Sang Ho;Suh, Yongsug;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.835-842
    • /
    • 2014
  • Cutback control in a grid code is one of the functions of a wind power plant (WPP) that is required to support the system protection and frequency stability. When a cutback control command signal is delivered to the WPP from the system operator, the output of a WPP should be decreased to 20% of the rated power within 5 s. In this paper, we propose a dedicated cutback control algorithm of a WPP based on the ratio of the command power to the available power. If a cutback control signal is delivered, the algorithm determines the pitch angle for the cutback control and starts the pitch angle control. The proposed algorithm keeps the rotor speed at the speed before the start of the cutback control to quickly recover the previous output prior to the cutback control. The performance of the algorithm was validated for a 100 MW aggregated WPP based on a permanent magnet synchronous generator under various wind conditions using an EMTP-RV simulator. The results clearly shows that the proposed algorithm not only successfully reduces the output to the command power within 5 s by minimizing the fluctuation of the pitch angle, but also rapidly recovers to the output level before the cutback control.

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

Analysis of Battery ESS Technology and its Effects for Generation Constraint (발전제약완화용 배터리 ESS 효과 분석 및 기술 적용)

  • Jung, Solyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2021
  • 우리나라 서해안 및 동해안지역에는 대규모 발전단지가 집중되어 운영 중이며 이 발전단지들의 발전력을 송전하고 있는 765kV 송전선로 2 회선 고장이 발생하는 경우 송전선로의 용량부족으로 인해서 수 GW 규모의 발전력을 불시에 탈락시키도록 보호체계(SPS, Special Protection System)가 운영 중이다. 이 SPS 가 동작하여 대규모 공급능력이 불시에 상실되면 급격한 주파수 하락이 발생하게 되어 저주파수계전기(Under Frequency Relay, UFR)가 동작할 수 있기 때문에 SPS 탈락 발전기의 출력을 상시에 감소시키는 제약비발전(Constraint off)을 시행하고 있다. 이 제약비발전으로 인해 매년 수천억원의 제약비용이 발생하고 있기 때문에 제약을 완화시키기 위한 방안으로 배터리 에너지저장장치(BESS)를 적용하는 사업이 추진되고 있다. 이는 "발전제약완화 에너지저장장치(이하 발전제약완화용 ESS) 사업"으로 불리며 전국 19 개 변전소에 총 1.4GW(2C-Rate)의 에너지저장장치가 설치되는 국내 최대규모의 BESS 사업이다. 향후 송전망 확충에 의해서 발전제약이 해소되는 경우 주파수 조정용, 재생에너지 변동성 완화용 등의 다목적 ESS 로 활용될 계획이다. 본 보고서에서는 발전제약완화 ESS 사업의 기술적 효과를 실효치 기반의 시뮬레이션(PSS/E v33.3)을 통해서 검토하였다.

Internal Fault Detection and Fault Type Discrimination for AC Generator Using Detail Coefficient Ratio of Daubechies Wavelet Transform (다우비시 웨이브릿 변환의 상세계수 비율을 이용한 교류발전기의 내부고장 검출 및 고장종류 판별)

  • Park, Chul-Won;Shin, Kwang-Chul;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.136-141
    • /
    • 2009
  • An AC generator is an important components in producing a electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. Conventionally, a DFT based RDR has been used for protecting the generator stator winding. However, when DFTs based on Fourier analysis are used, it has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. This paper proposes the internal fault detection and fault type discrimination for the stator winding by applying the detailed coefficients by Daubechies Wavelet Transform to overcome the defects in the DFT process. For the case studies reported in the paper, a model system was established for the simulations utilizing the ATP, and this verified the effectiveness of the proposed technique through various off-line tests carried out on the collected data. The propose method is shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault tested.