분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘 (An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations)

  • 신동열;김동명;차한주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

분산전원의 배전계통 연계에 따른 재폐로 계전기 운영 방향에 관한 연구 (The study on the direction of the reclosing relay operating for Distributed Generation interconnection with distribution power system)

  • 정종찬;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.655-656
    • /
    • 2007
  • 전력 계통에 연계형 분산전원이 도입되므로 인하여 기존배전선로와 달리 양방향 전력조류가 발생, 이에따른 보호계전방식의 수정을 필요로 하므로, PSCAD-EMTDC 시뮬레이터를 통하여, 이때의 배전계통의 현상들을 모의하고, 이에 따른 대책을 제시하므로 하여 배전계통 신뢰도를 향상시키기 위한 연구를 진행하였습니다. 기존선로를 이용해 연계된 분산전원과, 전용선로를 통하여 연계된 분산전원을 모의하고, 부하 상태와 사고 형태에 따른 시뮬레이션을 진행 현상을 분석하여 새로운 운영방식을 제시하였다.

  • PDF

태양광모듈과 리튬이온전지를 이용한 가동보용 친환경 전원공급장치의 설계 및 구현 (Design and Implementation of Eco-friendly Power Supply System for Moveable-weir Using PV Module and Li-ion Battery)

  • 강민관;최성식;남양현;이후동;박지현;노대석
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.186-193
    • /
    • 2018
  • Generally, it is difficult to operate moveable-weir due to the expensive cost of the facility management and manpower consumption. Also, when it is installed in a remote area, there is a problem that the cost of connection for power system increases as well as the operating cost. Therefore, this paper proposes an optimal design algorithm to replace an existing power system with an Eco-friendly power supply system for movable-weir using PCS, PV module and lithium-ion battery. Also, this paper proposes a modeling method of environment-friendly power supply system for a movable-weir based on the PSCAD/EMTDC S/W and implements 5[kW] prototype environment-friendly power supply system. As a result of the performance test using the S/W modeling and the prototype system, it is confirmed that the proposed system has stable characteristics in the independent operation mode and the interconnection mode.

정보통신용 다병렬 운전의 모듈식 무정전전원장치 (Module UPS of multi-parallel operation for use in information & telecommunication systems)

  • 구태근;류지수;배상규;박근갑
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

BILBO Network: a proposal for communications in aircraft Structural Health Monitoring sensor networks

  • Monje, Pedro M.;Aranguren, Gerardo
    • Structural Monitoring and Maintenance
    • /
    • 제1권3호
    • /
    • pp.293-308
    • /
    • 2014
  • In the aeronautical environment, numerous regulatory and communication protocols exist that cover interconnection of on-board equipment inside the aircraft. Developed and implemented by the airlines since the 1960s, these communication systems are reliable, strong, certified and able to contact different sensors distributed throughout the aircraft. However, the scenario is slightly different in the structural health monitoring (SHM) field as the requirements and specifications that a global SHM communication system must fulfill are distinct. The number of SHM sensors installed in the aircraft rises into the thousands, and it is impossible to maintain all of the SHM sensors in operation simultaneously because the overall power consumption would be of thousands of Watts. This design of a new communication system must consider aspects as management of the electrical power supply, topology of the network for thousands of nodes, sampling frequency for SHM analysis, data rates, selected real-time considerations, and total cable weight. The goal of the research presented in this paper is to describe and present a possible integration scheme for the large number of SHM sensors installed on-board an aircraft with low power consumption. This paper presents a new communications system for SHM sensors known as the Bi-Instruction Link Bi-Operator (BILBO).

남북한 연계선로 평가 및 최적안 선정에 관한 연구 (A Study on Evaluation of Tie Lines between North and South Korea and its Selection of the Best Alternative)

  • 차준민;노대석;최재석;김홍래;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.414-417
    • /
    • 2001
  • This paper presents the results of power flow of North-South Korea system with interconnected cases which were proposed by various present studies PSS/E and PowerWorld Simulator were used to analyze the inter connected system with several interconnected lines alternatives. The results would be very useful to select the best alternative for interconnection with considering several evaluation terms.

  • PDF

Active Frequency with a Positive Feedback Anti-Islanding Method Based on a Robust PLL Algorithm for Grid-Connected PV PCS

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.360-368
    • /
    • 2011
  • This paper proposes an active frequency with a positive feedback in the d-q frame anti-islanding method suitable for a robust phase-locked loop (PLL) algorithm using the FFT concept. In general, PLL algorithms for grid-connected PV PCS use d-q transformation and controllers to make zero an imaginary part of the transformed voltage vector. In a real grid system, the grid voltage is not ideal. It may be unbalanced, noisy and have many harmonics. For these reasons, the d-q transformed components do not have a pure DC component. The controller tuning of a PLL algorithm is difficult. The proposed PLL algorithm using the FFT concept can use the strong noise cancelation characteristics of a FFT algorithm without a PI controller. Therefore, the proposed PLL algorithm has no gain-tuning of a PI controller, and it is hardly influenced by voltage drops, phase step changes and harmonics. Islanding prediction is a necessary feature of inverter-based photovoltaic (PV) systems in order to meet the stringent standard requirements for interconnection with an electrical grid. Both passive and active anti-islanding methods exist. Typically, active methods modify a given parameter, which also affects the shape and quality of the grid injected current. In this paper, the active anti-islanding algorithm for a grid-connected PV PCS uses positive feedback control in the d-q frame. The proposed PLL and anti-islanding algorithm are implemented for a 250kW PV PCS. This system has four DC/DC converters each with a 25kW power rating. This is only one-third of the total system power. The experimental results show that the proposed PLL, anti-islanding method and topology demonstrate good performance in a 250kW PV PCS.

태양광발전의 배전계통 연계 알고리즘 개발에 관한 연구 (Development of Interconnection Algorithm for PV Systems in Distribution System)

  • 박재호;노대석;오용택;홍상은
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2005년도 춘계학술발표논문집
    • /
    • pp.128-131
    • /
    • 2005
  • 본 논문에서는 정해진 형태의 정보를 입력하면 태양광, 풍력 등의 분산형전원의 도입 및 운용에 대한 각종 정보를 상세하고 전문적(설계나 감리, 운용자 등)인 측면에서 제공받을 수 있는 시스템의 알고리즘을 개발하고자 한다. 구체적으로는 분산형전원의 계통연계 시에 발생할 수 있는 정상, 비정상(사고), 전력품질에 대한 9개의 항목으로 전력용량, 전기방식, 역률, 뱅크 역조류, 상시전압변동, 순시전압변동, 플리커, 단락용량, 연계가능용량 등이며, 분산형전원의 배전계통에의 연계 적합 여부를 종합적으로 판단하는 시스템이다.

  • PDF

A New Islanding Detection Method using Phase-Locked Loop for Inverter-Interfaced Distributed Generators

  • Chung, Il-Yop;Moon, Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.165-171
    • /
    • 2007
  • This paper proposes a new islanding detection method for inverter-interfaced distributed generators (DG). To detect islanding conditions, this paper calculates the phase angle variation of the system voltage by using the phase-locked loop (PLL) in the inverter controllers. Because almost all inverter systems are equipped with the PLL, the implementation of this method is fairly simple and economical for inverter-interfaced DGs. The detection time can also be shortened by reducing communication delay between the relays and the DGs. The proposed method is based on the fact that islanding conditions result in the frequency and voltage variation of the islanded area. The variation depends on the amount of power mismatch. To improve the accuracy of the detection algorithm, this paper injects small low-frequency reactive power mismatch to the output power of DG.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.