• 제목/요약/키워드: Power system dynamic stability

검색결과 353건 처리시간 0.031초

Transient stability improvement using quasi-multi pulse BTB-STATCOM

  • Vural, Ahmel M.;Bayindi, Kamil C.
    • Advances in Energy Research
    • /
    • 제2권1호
    • /
    • pp.47-59
    • /
    • 2014
  • Back-to-back STATCOM configuration is an extension of STATCOM in which the reactive power at two-sides and the real power flow through the DC link can be controlled concurrently and independently. This flexible operation brings many advantages to the micro-grids, distributed generation based systems, and deregulated power systems. In this paper, the dynamic control characteristics of the back-to-back STATCOM is investigated by simulating the detailed converter-level model of the converters in PSCAD. Various case studies in a single-machine test system are studied to present that the real power control feature of the BtB-STATCOM, even with a simple controller design, can enhance the transient stability of the machine under different fault scenarios.

Implementation of an Intelligent Grid Computing Architecture for Transient Stability Constrained TTC Evaluation

  • Shi, Libao;Shen, Li;Ni, Yixin;Bazargan, Masound
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.20-30
    • /
    • 2013
  • An intelligent grid computing architecture is proposed and developed for transient stability constrained total transfer capability evaluation of future smart grid. In the proposed intelligent grid computing architecture, a model of generalized compute nodes with 'able person should do more work' feature is presented and implemented to make full use of each node. A timeout handling strategy called conditional resource preemption is designed to improve the whole system computing performance further. The architecture can intelligently and effectively integrate heterogeneous distributed computing resources around Intranet/Internet and implement the dynamic load balancing. Furthermore, the robustness of the architecture is analyzed and developed as well. The case studies have been carried out on the IEEE New England 39-bus system and a real-sized Chinese power system, and results demonstrate the practicability and effectiveness of the intelligent grid computing architecture.

기울기 방법을 이용한 시분할 PI 전력계통 안정화 장치 (Time Division Proportional-Integral Power System Stabilizer Using The Gradiant Method)

  • 정해원;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.900-902
    • /
    • 1997
  • Stabilization of Power systems is investigated using a proportional-integral power system stabilizer(PI PSS). Time division PI PSS is examined in this paper. Two approaches are presented for determining the optimal stabilizer gains of the proposed PI PSS. Simulation results show that the proposed PI PSS yields better system dynamic performance and stability than the sub-optimal stabilizer in the sense of having greater damping in response to a step disturbance.

  • PDF

고분자 전해질 연료 전지용 공기공급계의 동특성 및 성능에 대한 연구 (Study on Dynamic Characteristic & Performance of the Air Supply System for PEM Fuel Cell)

  • 이희섭;김창호;이용복
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.45-53
    • /
    • 2006
  • Turbo-blower as an air supply system is one of the most important BOP (Balance of Plant) systems for FCV(Fuel Cell Vehicle). For generating and blowing compressed air, the motor of air blower consumes maximum 25% of net power, and fuel cell demands a clean air. In this study, turbo-blower supported by air foil bearings is introduced as the air supply system used by 80kW proton exchange membrane fuel systems. The turbo-blower is a turbo machine which operates at high speed, so air foil bearings suit their purpose as bearing elements. Analysis for confirming the stability and endurance is conducted. The rotordynamic stability was predicted using the numerical analysis of air foil bearings and it is verified through experimental works. In spite of various transient dynamic situation, the turbo-blower had stable performances. After the performance test, results are presented. The normal power of driving motor has about 1.6 kW with the 30,000 rpm operating range and the flow rate of air has maximum 160 SCFM. The test results show that the aerodymic performance and stability of turbo-blower are satisfied to the primary goals.

Dynamic Equivalents of the KEPCO System for the Stability Analysis

  • Lee, Hanmin;Kwon, Sae-hyuk;Gilsoo Jang;Lee, Byongjun;Byunghun Chang
    • KIEE International Transactions on Power Engineering
    • /
    • 제12A권1호
    • /
    • pp.20-25
    • /
    • 2002
  • This paper deals with the development of dynamic equivalents of the Korea Electric Corporation (KEPCO) systems. Several coherency identification methods are studied in order to find a proper method to well represent the dynamic characteristics of the KEPCO system. Also, this paper presents the comparison of the detail and classical aggregation methods in terms of the dynamic and static characteristics of the system. The nonlinear time simulation of the developed KEPCO equivalent system and the original system is performed to illustrate the validity of the equivalent system.

대규모 발전단지 상시제약 감소를 위한 에너지 저장장치(ESS) 적용에 관한 연구 (A Study on Energy Storage System(ESS) Application for Dynamic Stability Improvement and Generation Constraint Reduction)

  • 이재걸;정솔영;최장흠;김용학;윤용범
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1554-1560
    • /
    • 2017
  • Prepare a lose of 765kV transmission route in power system operation condition, there are some Special Protection Scheme(SPS)s in Korean power system. These SPS can make some preselected generators are tripped to avoid generator overspeed. Because of many of the new large power plants are installed to existing power generation sites due to the siting problem, the number of generator tripped by SPS should be increased. But that can be a cause of system frequency change under the Under Frequency Relay(UFR) 1st pickup level 59.0Hz. Therefore generation constraint should be considered until new transmission lines are installed. In this paper, we propose the ESS application for generation constraint mitigation by frequency damping control of ESS. To analysis an effect of ESS application, we use PSS/E dynamic simulation tool, CBEST model and controller model. The proposed ESS application is applied to the empirical Korean power system.

Combined Design of PSS and STATCOM Controllers for Power System Stability Enhancement

  • Rohani, Ahmad;Tirtashi, M. Reza Safari;Noroozian, Reza
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.734-742
    • /
    • 2011
  • In this paper a robust method is presented for the combined design of STATCOM and Power System Stabilizer (PSS) controllers in order to enhance the damping of the low frequency oscillations in power systems. The combined design problems among PSS and STATCOM internal ac and dc voltage controllers has been taken into consideration. The equations that describe the proposed system have been linearized and a Fuzzy Logic Controller (FLC) has been designed for the PSS. Then, the Particle Swarm Optimization technique (PSO) which has a strong ability to find the most optimistic results is employed to search for the optimal STATCOM controller parameters. The proposed controllers are evaluated on a single machine infinite bus power system with the STATCOM installed in the midpoint of the transmission line. The results analysis reveals that the combined design has an excellent capability in damping a power system's low frequency oscillations, and that it greatly enhances the dynamic stability of power systems. Moreover, a system performance analysis under different operating conditions and some performance indices studies show the effectiveness of the combined design.

DFIG 풍력터빈이 연계된 전력계통의 CCT 영향분석 (CCT Analysis of Power System Connected to DFIG Wind Turbine)

  • 서규석;박지호
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2388-2392
    • /
    • 2013
  • 풍력발전시스템은 기존의 발전시스템과 매우 다르다. 그러므로 전력계통에 풍력시스템을 연계하기 위해서는 동적특성에 대한 연구가 필요하다. 풍력발전기의 안정도해석은 전력계통의 운영에 있어서 중요 쟁점이다. 기존의 동기발전기만으로 구성된 전력계통의 위상각 안정도는 풍력발전기가 포함되면 그 결과가 달라진다. 즉, 풍력터빈에 연계된 발전기는 대부분 비동기인 유도발전기이기 때문이다. 위상각의 동기화 여부로 판별하는 위상각 안정도는 임계고장제거시간(CCT)을 계산하여 평가한다. 계통해석용 풍력터빈의 모델은 다양하여 그 해석에 어려움이 있으나 지금은 크게 4가지 타입으로 표준화가 되어있다. 본 논문에서는 PSS/E-32에서 제공하는 풍력터빈의 3번째 표준모델인 DFIG(Doubly-Fed induction Generator)모델을 이용하여 풍력단지가 연계된 전력계통의 CCT를 풍력단지의 위치와 용량을 고려하여 분석한다.

Dynamic Synchronous Phasor Measurement Algorithm Based on Compressed Sensing

  • Yu, Huanan;Li, Yongxin;Du, Yao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권1호
    • /
    • pp.53-76
    • /
    • 2020
  • The synchronous phasor measurement algorithm is the core content of the phasor measurement unit. This manuscript proposes a dynamic synchronous phasor measurement algorithm based on compressed sensing theory. First, a dynamic signal model based on the Taylor series was established. The dynamic power signal was preprocessed using a least mean square error adaptive filter to eliminate interference from noise and harmonic components. A Chirplet overcomplete dictionary was then designed to realize a sparse representation. A reduction of the signal dimension was next achieved using a Gaussian observation matrix. Finally, the improved orthogonal matching pursuit algorithm was used to realize the sparse decomposition of the signal to be detected, the amplitude and phase of the original power signal were estimated according to the best matching atomic parameters, and the total vector error index was used for an error evaluation. Chroma 61511 was used for the output of various signals, the simulation results of which show that the proposed algorithm cannot only effectively filter out interference signals, it also achieves a better dynamic response performance and stability compared with a traditional DFT algorithm and the improved DFT synchronous phasor measurement algorithm, and the phasor measurement accuracy of the signal is greatly improved. In practical applications, the hardware costs of the system can be further reduced.