• 제목/요약/키워드: Power system analysis

검색결과 9,430건 처리시간 0.036초

회전 변형항을 고려한 진동파워 전달 경로별 기여도 분석 : 압축기계에의 응용 (Vibrational Power Path Analysis with Rotational Terms Included and Its Application to Compressor System)

  • 이호정;김광준
    • 한국소음진동공학회논문집
    • /
    • 제15권3호
    • /
    • pp.280-289
    • /
    • 2005
  • A single degree of freedom system and transmissibility are key concepts in many problems of vibration isolation. In order to apply this approach, however, several assumptions must be satisfied, which are often not realistic. For examples, in practical systems, vibration transmissions at multi-point with multi-degree of freedom(translational and rotational DOF) take place and mobilities or impedances of receiver structures cannot be ignored any more especially over high frequency range. Therefore, a multi-dimensional treatment is required for accurate estimation of dynamic behavior of the system. In this paper, an approach using vibrational power flow is introduced to deal with analysis of multi-dimensional vibration isolation system in a more practical way and in aspects of vibration isolations and vibration path analysis. Procedures of this approach and some results of research for vibrational power path analysis with rotational terms included are presented. Difficulties in this method are also discussed.

지향성 에너지 무기체계와 고출력 마이크로파 무기 효과도 분석 (Directed Energy Weapon System and Analysis on Effectiveness HPM Weapon)

  • 김일규;김문섭
    • 한국전자파학회논문지
    • /
    • 제27권10호
    • /
    • pp.935-940
    • /
    • 2016
  • 지향성 에너지 무기는 순간적으로 집중된 에너지를 특정한 방향으로 방사하여 적 전자장비를 교란하거나 과부하를 초래하는 무기체계이다. 이러한 지향성 에너지 무기체계의 성능을 결정하고, 설계를 수행함에 있어 표적에 대한 효과 분석은 중요한 고려 요소 중 하나이다. 본 논문에서는 대표적인 지향성 에너지 무기체계인 공중방어체계에 대한 효과도를 분석하였다. 이를 위하여 고출력 원형편파 피드혼을 적용한 반사판 안테나를 설계하고, 거리 별 유효면적에 인가되는 출력밀도를 시뮬레이션 툴과 프리스 공식을 활용하여 분석하였다. 이를 통하여 안테나 시스템 설계에 대한 유효성을 검증하고, 표적에 대한 지향성 에너지 무기의 효과를 확인하였다.

Vulnerability Assessment of a Large Sized Power System Using Neural Network Considering Various Feature Extraction Methods

  • Haidar, Ahmed M. A;Mohamed, Azah;Hussian, Aini
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.167-176
    • /
    • 2008
  • Vulnerability assessment of power systems is important so as to determine their ability to continue to provide service in case of any unforeseen catastrophic contingency such as power system component failures, communication system failures, human operator error, and natural calamity. An approach towards the development of on-line power system vulnerability assessment is by means of using an artificial neural network(ANN), which is being used successfully in many areas of power systems because of its ability to handle the fusion of multiple sources of data and information. An important consideration when applying ANN in power system vulnerability assessment is the proper selection and dimension reduction of training features. This paper aims to investigate the effect of using various feature extraction methods on the performance of ANN as well as to evaluate and compare the efficiency of the proposed feature extraction method named as neural network weight extraction. For assessing vulnerability of power systems, a vulnerability index based on power system loss is used and considered as the ANN output. To illustrate the effectiveness of ANN considering various feature extraction methods for vulnerability assessment on a large sized power system, it is verified on the IEEE 300-bus test system.

광역 방어시스템의 통신 트래픽 모사와 분석 (Simulation and Analysis of the Network Traffic of a Power Infrastructure Defense System)

  • 백윤기;이건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.179-180
    • /
    • 2006
  • The real time monitoring of the power systems covering wide area are essential for the stable operation and control of the power system. Synchronized phasor measurement is a key for the precise monitoring and control of the power systems. In this paper, to suggest an appropriate network topology of Power Infrastructure Defense System(PIDS) and to estimate the maximum network bandwidth with using the network analyzer, we simulate a PIDS and analyze the network traffic.

  • PDF

동력경운기(動力耕耘機)의 안정성(安定性) 향상(向上)을 위한 주행(走行) 및 선회(旋回)에 관(關)한 연구(硏究)(II) -동력경운기(動力耕耘機)-트레일러 시스템의 운동(運動)모델의 개발(開發) (Motion Analysis of Power Tiller for Stability Improvement -Development of A Mathematical Model of Motion for Power tiller-Trailer System)

  • 박금주;류관희;정창주
    • Journal of Biosystems Engineering
    • /
    • 제12권3호
    • /
    • pp.17-29
    • /
    • 1987
  • A 10-degree of freedom mathematical model of motion for power tiller-trailer system was developed. This model can predict motion characteristics of power tiller trailer system while travelling over smooth and irregular ground surfaces under various operating conditions. The model provide, the fundamental data needed to improve the stability of power tiller-trailer systems.

  • PDF

연속조류계산 시스템의 개발 (The Development of a Continuation Power Flow System)

  • 송화창;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.894-896
    • /
    • 1997
  • This paper presents the continuation power flow system that is under development. The continuation power flow system provides robust solutions of power flow equations at any operating point. The robust convergency enables one to find solutions even at the point where power flow jacobian becomes singular. Basic concept of an algorithm and its application to static voltage stability analysis are presented.

  • PDF

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

Experimental and Theoretical Study on the Prediction of Axial Stiffness of Subsea Power Cables

  • Nam, Woongshik;Chae, Kwangsu;Lim, Youngseok
    • 한국해양공학회지
    • /
    • 제36권4호
    • /
    • pp.243-250
    • /
    • 2022
  • Subsea power cables are subjected to various external loads induced by environmental and mechanical factors during manufacturing, shipping, and installation. Therefore, the prediction of the structural strength is essential. In this study, experimental and theoretical analyses were performed to investigate the axial stiffness of subsea power cables. A uniaxial tensile test of a 6.5 m three-core AC inter-array subsea power cable was carried out using a 10 MN hydraulic actuator. In addition, the resultant force was measured as a function of displacement. The theoretical model proposed by Witz and Tan (1992) was used to numerically predict the axial stiffness of the specimen. The Newton-Raphson method was employed to solve the governing equation in the theoretical analysis. A comparison of the experimental and theoretical results for axial stiffness revealed satisfactory agreement. In addition, the predicted axial stiffness was linear notwithstanding the nonlinear geometry of the subsea power cable or the nonlinearity of the governing equation. The feasibility of both experimental and theoretical framework for predicting the axial stiffness of subsea power cables was validated. Nevertheless, the need for further numerical study using the finite element method to validate the framework is acknowledged.

PHILS 기반 2 MW급 조류발전시스템 특성 분석 (PHLIS-Based Characteristics Analysis of a 2 MW Class Tidal Current Power Generation System)

  • 고병수;성해진;박민원;유인근
    • 한국정밀공학회지
    • /
    • 제31권8호
    • /
    • pp.665-670
    • /
    • 2014
  • In this paper, characteristics of a tidal current power generation system are analysis using power hardware-in-the-loop simulation (PHILS). A 10 kW motor generator set is connected to the real grid through a fabricated 10 kW back to back converter. A power control scheme is applied to the back to back converter. A 2 MW class tidal current turbine is modeled in real time digital simulator (RTDS). Generating voltage and current from the 10 kW PMSG is applied to a 2 MW class tidal current turbine in the RTDS using PHILS. The PHILS results depict the rotation speed, power coefficient, pitch angle, tip-speed ratio, and output power of tidal current turbine. The PHILS results in this paper can contribute to the increasing reliability and stability of the tidal current turbines connected to the grid using PHILS.

태양광 발전 시스템에서의 벅 컨버터 모델링과 해석 (Modeling and Analysis of The Buck Converter in Photovoltaic Power Conditioning System)

  • 정승환;최익;최주엽
    • 한국전자통신학회논문지
    • /
    • 제8권7호
    • /
    • pp.1039-1048
    • /
    • 2013
  • 일반적으로 벅 컨버터 제어기는 컨버터의 출력 전압을 제어하도록 설계하지만, 태양광발전시스템에서의 벅 컨버터 제어기는 설계 방식을 달리 구분해야 한다. 본 논문에서는 MPPT(Maximum Power Point Tracking)을 위하여 벅 컨버터의 입력 전압(태양광전지의 출력 전압)을 제어한다고 가정하였다. 또한, 컨버터의 입력 전압을 제어하기 위한 새로운 벅 컨버터 모델을 제시한다. 이 컨버터 모델은 최대전력점(MPP)에서 동작점을 두어 선형화한 태양광전지의 모델을 포함하며, 모델의 타당성을 검증하기 위하여 대신호와 소신호로 나누어 분석한다. 또한 일반적인 선형제어기를 설계하였을 때, 제어 가능성을 분석하여 검증한다.