• 제목/요약/키워드: Power system analysis

검색결과 9,420건 처리시간 0.047초

Simulink를 이용한 전동차용 전력변환장치의 시뮬레이션에 관한 연구 (A study on the simulation for the power converting system of the electric train using Simulink)

  • 강문호;한문섭;이재호;창상훈;이종우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.625-628
    • /
    • 1996
  • Recent power converting system for an electric train has characteristics of a complex electromechanical system, which includes VVVF inverter, bidirectional converter, ac motor and controller and etc. So in order to analysis its dynamic characteristics reliably, a powerful and flexible simulation technique is needed. Concerned with this respect, because the Simulink has a veriety of powerful functions and analysis tools not available in conventional power electronics simulation packages, it can be effectively applied to the simulation of the power converting system. In this paper, a schematically similar model for an electric train power converting system is derived on the Simulink Window, based on the Dynamic Node Technique, and several simulations have been implemented with the model. With the simulation results, the characteristics of the power converting system and the easeness of the proposed Simulink-based simulation technique could be verified clearly.

  • PDF

열병합발전설비가 연계된 배전계통 순시전압변동 및 사고해석에 관한 연구 (A Study on Momentary Voltage Variations and Fault Analysis in the Power Distribution System with Congeration Facilities (COGN).)

  • 정성교;최준호;김대원;김재철;손학식;김윤우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1192-1194
    • /
    • 1999
  • Recently, there has been growing interest in utilizing cogeneration(COGN) system which has high energy efficiency due to the lacking of energy resource, but insertion of cogeneration system into existing power distribution system can cause several problems such as voltage variations, reenergizing of feeder isolated by fault, increasing fault current because of reverse power of COGN. Also these problems increase the complexity of control, protection, and maintenance of power distribution systems. Hence, some problems according to COGN interconnection operation to power distribution system must be taken into account so that operation and security of power distribution system is not disturbed. This paper deals with momentary voltage variations and fault analysis caused by interconnection operation of COGN.

  • PDF

Analysis and comparison of the 2D/1D and quasi-3D methods with the direct transport code SHARK

  • Zhao, Chen;Peng, Xingjie;Zhang, Hongbo;Zhao, Wenbo;Li, Qing;Chen, Zhang
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.19-29
    • /
    • 2022
  • The 2D/1D method has become the mainstream of the direct transport calculation considering the balance of accuracy and efficiency. However, the 2D/1D method still suffers from stability issues. Recently, a quasi-3D method has been proposed with axial Legendre expansion. Analysis and comparison of the 2D/1D and quasi-3D method is conducted in theory from the equation derivation. Besides, the C5G7 benchmark, the KUCA benchmark and the macro BEAVRS benchmark are calculated to verify the theory comparisons of these two methods with the direct transport code SHARK. All results show that the quasi-3D method has better stability and accuracy than the 2D/1D method with worse efficiency and memory cost. It provides a new option for direct transport calculation with the quasi-3D method.

독립형 태양광 발전을 이용한 효율적인 하이브리드 LED 가로등 조명관리 시스템 설계 (An Efficient Hybrid LED Street Lighting Management System Design using Standalone Solar Photovoltaic)

  • 홍성일;인치호
    • 제어로봇시스템학회논문지
    • /
    • 제20권9호
    • /
    • pp.984-993
    • /
    • 2014
  • In this paper, we propose a design for an efficient hybrid LED street lighting management system using standalone solar photovoltaic. The proposed efficient hybrid LED street lighting management system was composed of hybrid power conditioning system, gateways, LED street lights and a monitoring server. The hybrid power conditioning system was designed to charge produced power by solar photovoltaic panels in day time, and supply power to the LED street lights in night time. If there is insufficient power, the system was designed to operate using firm power, because the system utilizes photovoltaic power. A system control algorithm allied to the lighting management system, and experimented by being configured to the functions that are able to perform real-time monitoring and remote control through the lighting management system even when absent. In the result of the efficiency analysis of the hybrid lighting management system proposed in this paper, we were able to increase the energy efficiency compared to existing lighting control systems by reducing power consumption and electricity costs.

RTD Bypass Line Elimination at Kori Nuclear Power Plant 3&4

  • Yoon, Duk-Joo;Lee, Chang-Sup;Jun, Hwang-Yong;Lee, Jae-Yong;Song, Dong-Soo
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.213-218
    • /
    • 1997
  • The RTD Bypass Loops at Kori Unit 3&4 will be removed and a new system will be designed and will be installed to replace it. The replacement system provides equal or better performance and eliminates some Persistent problems. The Resistance Temperature Detector (RTD) bypass line is eliminated to reduce the radiation exposure to operators and workers. After the elimination, the resistance temperature detectors are installed in scoop of the reactor coolant piping to detect a representative temperature. This study includes safety evaluation, RTD response time Analysis, Uncertainty Analysis, LOCA evaluation and Structural Analysis.

  • PDF

건물 에너지 분석 및 에너지 관리 시스템 알고리즘에 관한 연구 (A Study on the Building Energy Analysis and Algorithm of Energy Management System)

  • 한병조;박기광;구경완;양해원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.505-510
    • /
    • 2009
  • In this paper, building energy analysis and energy cost of power stand up and demand control over the power proposed to reduce power demand. Through analysis of the load power demand special day were able to apply the pattern. In addition, the existing rate of change of load forecasting to reduce the large errors were not previously available data. And daily schedules and special day for considering the exponential smoothing methods were used. Previous year's special day and the previous day due to the uncertainty of the load and the model components were considered. The maximum demand power control simulation using the fuzzy control of power does not exceed the contract. Through simulation, the benefits of the proposed energy-saving techniques were demonstrated.

HVDC 시스템의 고장 시 소음 및 진동 분석 (The Sound Noise and Vibration Analysis for HVDC System Faults)

  • 김찬기;박종광;최영도;임성주;문형배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2006
  • This paper deals with the HVDC system fault analysis and the sound noise analysis. In this paper, the reasons of the audible noise and vibration were analyzed, the fault waveform were analyzed using DTR (Digital Transient Recorder). Finally, using the fault current waveform and the vibration equation, the reason of crack of smoothing reactor support is estimated.

  • PDF

낙뢰침입에 의한 대지전위상승이 발전소 저압전원회로에 미치는 과전압 해석 (Transient Voltage Analysis of Low-Voltage Source Circuit inn Thermal Power Plant due to Grounding Potential Rise by Lightening)

  • 양병모;정재기;민병욱;이종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1644-1646
    • /
    • 1998
  • High-Smokestacks have been the symbol of the thermal power plant. Those cause the thermal power plant to be damaged by lightening for reaching several hundreds meter. In this paper, we investigated the accident of low-voltage source circuit due to grounding potential rise by lightening via high-smokestack in practically driving power plant, described examination into the cause and the impulse analysis. We analysed the transient voltage by EMTP(ElectroMagnetic Transient Program) via modeling the grounding system of power plant. This theoretical results coincided with practical accidental state. Therefore, it was verified that we could apply the grounding system of power plant and substation with the distribution-circuit analysis(EMTP).

  • PDF

케프란 마이크로터빈의 모델링 해석에 관한 연구 (A Study on the Modeling Analysis for Kaplan Micro-turbines)

  • 김옥삼;김일수;김학형;심지연
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.105-110
    • /
    • 2006
  • Among many other alternative energy resources, small scale hydro power has been brought into attention as a reliable source of energy today, which had been relatively neglected since 1960s. Especially, Kaplan micro-turbine can be applied to various kind of small hydro power plants, such as reservoirs for agriculture purpose, sewage treatment plants and water purification plants. However present low head of Kaplan micro-turbines and small scale hydro turbines, have limitations in the minimum required head and flow rate for efficient operation. This research is to develop modeling analysis for the Kaplan micro-turbine, which can improve economical features of small hydro power plants. The contents and scope of this research are the efficiency improvement of Kaplan micro-turbine.

  • PDF

역회복 현상을 고려한 전기자동차용 IPT 시스템의 Semi-Bridgeless 정류기 분석 (Analysis of Semi-Bridgeless Rectifier in Inductive Power Transfer Systems for Electric Vehicles Considering Reverse Recovery Phenomenon)

  • 손원진;안상준;변종은;이재한;이병국
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.327-333
    • /
    • 2019
  • This study analyzes the reverse recovery phenomenon of a semi-bridgeless rectifier (SBR) in an inductive power transfer (IPT) system for electric vehicles. Ideally, the reverse recovery phenomenon does not occur in a diode rectifier, however, in practical systems, the reverse recovery phenomenon occurs even when the SBR operates like a diode rectifier due to high operating frequency. Therefore, a practical analysis of operation modes for SBRs is presented in this study, considering the reverse recovery phenomenon, and the requirements for SBR switches are proposed. The analysis results are experimentally verified using a 3.3 [kW] IPT system prototype to which three different types of switches are applied.