Harmonics analysis based on a frequency domain in Electric Feeding System (전기철도 급전시스템의 주파수 기반모델을 이용한 고조파 해석)

  • Han Moonseob;Lee Jangmu;Jung Hosung;Kim Joorak
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1315-1318
    • /
    • 2004
  • Each feeding power is transformed 3 phases of KEPCO through SCOTT transformer and operate a electric train in AC Feeding system of electric railway. Nowaday a power conversion system, installed inside the train, generate a harmonics and has a effect on a power quality and it is necessary to install a countermeasures. This report is proposed a new technique to simulate a power system based on frequency model. The result is resonable relatively with a experimental one.

  • PDF

Real Time Implementation of Active Power Filters for Harmonic Suppression and Reactive Power Compensation using dSPACE DS1104

  • Kumar, Seethapathy;Umamaheswari, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.373-378
    • /
    • 2008
  • In this paper, an Active Power Filter (APF) is implemented using a dSPACE DS1104 processor to compensate harmonics and reactive power produced by nonlinear load. The reference source current is computed based on the measurement of harmonics in the supply voltage and load current. A hysteresis based current controller has been implemented in a DSP processor for injecting the compensating current into the power system, so that APF allows suppression of the harmonics and reactive power component of load current, resulting in a supply current that is purely sinusoidal. Simulation and experimental results of the proposed APF to meet the IEEE-519 standards are presented.

Reduction of Harmonics and Compensation of Reactive Power about Wind Power Generation System Connected to Grid (계통 연계형 풍력발전 시스템의 고조파 저감 및 무효전력 보상)

  • Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man;Park, Hyun-Chul;Song, Seung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1093-1096
    • /
    • 2002
  • In this paper, a novel multi voltage inverter system is proposed for reductions of harmonics, which can compensate reactive power. At first, we remove capacitor at input side for reactive power compensation. Secondly, by adding DC voltage to the filter capacitor, it can control power factors as lead-phase according to alterations of loads at power reception. Thirdly, if winding and single phase-bridge inverter(auxiliary circuit) is installed to DC power for reduction of harmonic, waveform of output voltages become to 36-steps. Thus, SVC(static var compensator) systems which can reduce harmonics are designed.

  • PDF

A Development of Load Modeling Technique with Harmonics (고조파를 고려한 지능형 부하모델링 기법 개발)

  • Park, J.W.;Lee, J.P.;Byun, S.J.;Lim, J.Y.;Ji, P.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.551-552
    • /
    • 2007
  • Increasingly nonlinear dynamic loads have been connected into power systems. This adds to the harmonics in the power system. In traditional load modeling techniques, the harmonics has not been considered. Thus, the harmonics problems in load modeling are considered and ANN load modeling is proposed.

  • PDF

Harmonic and Interhamonic Detection and Estimation of Power Signal using Subband MUSIC/ESPRIT (부밴드 MUSIC/ESPRIT를 이용한 전력신호 고조파 및 중간고조파 검출 및 추정)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.149-158
    • /
    • 2015
  • This paper proposes a subband filtering technique to the MUSIC and the ESPRIT algorithm for estimating the magnitude and frequency of the harmonics of power signal. In proposed method, the input power signal is decomposed to the odd harmonics and the even harmonics respectively by the filter bank system. The amplitude and the frequency estimation of the decomposed harmonics are carried out using the MUSIC and the ESPRIT method. Subband filtering can reduce the autocorrelation matrix size of input data, and spectrum leakage between adjacent harmonics. Therefore, this subband technique has advantage in computational cost and estimation accuracy compared to fullband MUSIC and ESPRIT. To demonstrate the performance of the method, computer simulations are performed to the synthesized input signal, and experiment results are compared in subband and fullband cases.

Research on the Inter-harmonics Equivalent Impedance of Series Hybrid Active Power Filter

  • Jian-gong, Zhang;Jian-ben, Liu;Shao-jun, Dai;Qiao-fu, Chen;Jun-jia, He
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2062-2069
    • /
    • 2015
  • In the series hybrid active power filter (SHAPF) with magnetic flux compensation (MFC), the system current oscillate in the experimental results when adding the same phase harmonic current command in current control block. This condition endangers the security of the SHAPF. Taking the digit period average arithmetic as example, this paper explains the inter-harmonics current oscillation in the experiment. The conclusion is that the SHAPF is unstable to the inter-harmonics current in theory. Limited by the capacity of the inverter, the system current and the inverter output current do not increase to infinite. At last, some methods are proposed to solve this problem. From the practical viewpoint, the voltage feed-forward control is easy to achieve. It can suppress the current oscillation problems, and also improve the filtering effect. The feasibility of the methods is validated by both the emulation and experiment results.

Power Loss Analysis of Transformer Caused By Current Harmonics (전류 고조파에 기인하는 변압기 손실 해석)

  • Jang, Seungyong;Han, Sanghoon;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.34-41
    • /
    • 2016
  • This study investigates transformer losses caused by current harmonics. Electrical transformers are designed to work under sinusoidal voltage and current waves at a rated frequency. Recently, various nonlinear loads, such as power electronic converters, are connected to a power system; these converters generate current harmonics. Current harmonics increase power loss in transformers, which results in several problems, including temperature increase of the transformer and insulation damage. These problems will eventually shorten the operational life of the transformer. In this study, different types of losses caused by current harmonics in three-phase transformers are studied under linear and nonlinear load conditions. Linear loads are simulated and experimented on using pure resistance load, whereas nonlinear loads are simulated and experimented on using a three-phase twelve-pulse thyristor full-bridge rectifier. The different types of losses in three-phase transformers are evaluated analytically through the experimental result and simulation in PSiM.

Harmonics Analysis and Modelling for Distribution System (배전 시스템의 고조파 분석 및 모델링에 관한 연구)

  • Sung Byung H;Wang Yong P;Chung Hyuong H;Park Hea C;Park In P
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.267-269
    • /
    • 2004
  • Recently, due to increasing the application of power electronic equipment, harmonics generated from the non-liner load are fairy produced. Harmonics can cause a distribution problems such as the overheating of distribution transformer, the breakdown of device and communication interference. Interest about power quality decline of distribution system is very increased. In this paper, we are measured the harmonic voltage and current of distribution system to analyze harmonic characteristics, and it is analyzed Total Harmonic Distortion(HTD). Also, we are modeled distribution system using PSCAD/EMTDC. And it is analyzed harmonic voltage and current in steady-state. The study result have been indicated the utility about harmonics analysis and modeling for distribution system.

  • PDF

3-Phase Hybrid Series Active Power Filter with Dynamic Voltage Restorer (DVR 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • Han Seok-Woo;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.598-602
    • /
    • 2002
  • This paper presents the 3-phase hybrid series active power filter with dynamic voltage restorer(DVR) which serve as an energy buffer and current harmonics blocking resistor connected to sensitive loads, such as, to compensate voltage dips and current harmonics in power distribution system. The DVR is to inject a dynamically controlled voltage generated by a forced commutated converter in series to the bus voltage by means of a booster transformer. The momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage. The proposed system is able to simultaneously compensate current harmonics, voltage fluctuating and voltage unbalance in power distribution systems. The reference phase angle detected by synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The effectiveness of proposed system is verified by the computer simulation.

  • PDF

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.