• 제목/요약/키워드: Power smoothing

검색결과 157건 처리시간 0.031초

AREA 활용 전력수요 단기 예측 (Short-term Forecasting of Power Demand based on AREA)

  • 권세혁;오현승
    • 산업경영시스템학회지
    • /
    • 제39권1호
    • /
    • pp.25-30
    • /
    • 2016
  • It is critical to forecast the maximum daily and monthly demand for power with as little error as possible for our industry and national economy. In general, long-term forecasting of power demand has been studied from both the consumer's perspective and an econometrics model in the form of a generalized linear model with predictors. Time series techniques are used for short-term forecasting with no predictors as predictors must be predicted prior to forecasting response variables and containing estimation errors during this process is inevitable. In previous researches, seasonal exponential smoothing method, SARMA (Seasonal Auto Regressive Moving Average) with consideration to weekly pattern Neuron-Fuzzy model, SVR (Support Vector Regression) model with predictors explored through machine learning, and K-means clustering technique in the various approaches have been applied to short-term power supply forecasting. In this paper, SARMA and intervention model are fitted to forecast the maximum power load daily, weekly, and monthly by using the empirical data from 2011 through 2013. $ARMA(2,\;1,\;2)(1,\;1,\;1)_7$ and $ARMA(0,\;1,\;1)(1,\;1,\;0)_{12}$ are fitted respectively to the daily and monthly power demand, but the weekly power demand is not fitted by AREA because of unit root series. In our fitted intervention model, the factors of long holidays, summer and winter are significant in the form of indicator function. The SARMA with MAPE (Mean Absolute Percentage Error) of 2.45% and intervention model with MAPE of 2.44% are more efficient than the present seasonal exponential smoothing with MAPE of about 4%. Although the dynamic repression model with the predictors of humidity, temperature, and seasonal dummies was applied to foretaste the daily power demand, it lead to a high MAPE of 3.5% even though it has estimation error of predictors.

에너지저장장치를 이용한 풍력발전 출력 제어 성능 평가 (Assessment of performance for Output Power Control of Wind Turbine using Energy Storage System)

  • 홍종석;최창호;이주연;김재철
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.254-259
    • /
    • 2014
  • In this paper, we describe construction of a wind stabilization demo-site and effects of output power control of wind turbines for suppression of ramp rate using ESS (Energy Storage System). It is difficult to control the output power of distributed generator such as wind turbine which of variation is very large. If the large capacity wind farm be interconnected into power system may cause blackout due to Power Quality. For these reasons, the international standards such as Grid-Code is limited to less than 10 [%/min] of renewable energy ramp rate. The case of Korea, government actively conducts propagating large-scale renewable energy for green growth policy, to interconnecting more renewable energy into power system is necessary for stabilization technology. For these reasons, the POSCO consortium has constructed a wind stabilization demo-site that is configured as 500 [kWh] battery energy storage systems can output up to 3 [C-Rate] and two wind turbines rated 750 [kW]. In POSCO consortium, which implements various methods stabilizing output power of wind turbine such as smoothing, section firming and ramp control, we derive the results of long-term demonstration that can be controlled to satisfy to the international standard about ramp rate [%/kW] of wind turbine output power.

PWM 컨버터를 이용한 계통연계형 태양광발전 시스템 (A Utility Interactive Photovoltaic Generation System using PWM Converter)

  • 김대균;전기영;함연근;이승환;이승환;오봉환;이훈구;한경희
    • 전기학회논문지P
    • /
    • 제54권3호
    • /
    • pp.111-118
    • /
    • 2005
  • Since the residential load is an AC load and the output of solar cell is DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feed-forward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

최대 전력수요 예측을 위한 시계열모형 비교 (Comparison of time series predictions for maximum electric power demand)

  • 권숙희;김재훈;손석만;이성덕
    • 응용통계연구
    • /
    • 제34권4호
    • /
    • pp.623-632
    • /
    • 2021
  • 본 연구에서는 여러가지 시계열 모형 중 평활법(가법계절지수, 승법계절지수), 계절 ARIMA 모형, ARARCH 그리고 AR-GARCH 회귀모형을 이용하여 최대 전력수요를 예측하는 방법을 연구하였다. 이 때 가중 평균모형으로 추세를 갖는 시계열 모형과 온도에 대한 회귀 모형을 적절한 가중치로 예측 정확도를 높이는 방법도 연구하였다. 결과적으로 AR-GARCH 회귀모형으로 예측하는 것이 가중 우수함을 보였다.

풍력 수용 한계량 향상을 위한 발전기 무효전력 평활화 제어 기법 (Generator Control Method for Reactive Power Smoothing to increase Wind Power Penetration)

  • 최윤혁;이환익;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.197-198
    • /
    • 2015
  • As the global to increase the wind power penetration in the power system, grid-integration standards have been proposed for the stable integration of the large-scale wind farm. Particularly, the low voltage ride through function has been emphasized, as it relates to the voltage and reactive power control of the wind turbine and the rest generators. This paper proposes the non-wind power generator control method in order to improve the wind power penetration. To prove the effectiveness of the proposed strategy, the simulation study is implemented in the Jeju power system. It can improve the wind power penetration by the effective control of the control generators.

  • PDF

제주지역 계통운전조건을 고려한 풍력발전단지용 최소 BESS용량 산정 (Estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Isalnd)

  • 진경민;김승현;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.39-45
    • /
    • 2013
  • This paper presents the estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Island. To analyze the characteristics of wind farm outputs with a BESS, the real data of wind farms, Sung-San, Sam-dal and Hang-Won wind farm, located in the eastern part of Jeju island is considered. The wind farms are connected to Sung-san substation to transfer the electric power to Jeju power grid. Consequently, at PCC (Point of Common Coupling), it can see a huge wind farm connected to the substation and thus it can be expected that the smoothing effect is affected by not only the different wind speeds for each area but also the different mechanical inertia of wind turbines. In this paper, two kinds of simulation have been carried out. One is to analyze the real data of wind farm outputs during a winter season, and the other is to connect a virtual BESS to eliminate the unintended generating power changes by the uncontrolled wind farm outputs as shown in the former data. In the conclusion, two kinds of simulation results show that BESS installed in the substation is more efficient than each wind farms with BESS, respectively.

Validation Comparison of Credit Rating Models Using Box-Cox Transformation

  • Hong, Chong-Sun;Choi, Jeong-Min
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권3호
    • /
    • pp.789-800
    • /
    • 2008
  • Current credit evaluation models based on financial data make use of smoothing estimated default ratios which are transformed from each financial variable. In this work, some problems of the credit evaluation models developed by financial experts are discussed and we propose improved credit evaluation models based on the stepwise variable selection method and Box-Cox transformed data whose distribution is much skewed to the right. After comparing goodness-of-fit tests of these models, the validation of the credit evaluation models using statistical methods such as the stepwise variable selection method and Box-Cox transformation function is explained.

  • PDF

단파효과를 고려한 단기전력 부하예측 (Short-term Electric Load Prediction Considering Temperature Effect)

  • 박영문;박준호
    • 대한전기학회논문지
    • /
    • 제35권5호
    • /
    • pp.193-198
    • /
    • 1986
  • In this paper, 1-168 hours ahead load prediction algorithm is developed for power system economic weekly operation. Total load is composed of three components, which are base load, week load and weather-sensitive load. Base load and week load are predicted by moving average and exponential smoothing method, respectively. The days of moving average and smoothing constant are optimally determined. Weather-sensitive load is modeled by linear form. The paramiters of weather load model are estimated by exponentially weighted recursive least square method. The load prediction of special day is very tedious, difficult and remains many problems which should be improved. Test results are given for the day of different types using the actual load data of KEPCO.

  • PDF

주간수요예측 전문가 시스템 개발 (Development of a Weekly Load Forecasting Expert System)

  • 황갑주;김광호;김성학
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.365-370
    • /
    • 1999
  • This paper describes the Weekly Load Forecasting Expert System(Named WLoFy) which was developed and implemented for Korea Electric Power Corporation(KEPCO). WLoFy was designed to provide user oriented features with a graphical user interface to improve the user interaction. The various forecasting models such as exponential smoothing, multiple regression, artificial nerual networks, rult-based model, and relative coefficient model also have been included in WLofy to increase the forecasting accuracy. The simulation based on historical data shows that the weekly forecasting results form WLoFy is an improvement when compared to the results from the conventional methods. Especially the forecasting accuracy on special days has been improved remakably.

  • PDF

에너지 저장장치 내장형 하이브리드 전력변환장치를 이용한 계통안정화연구 (A Study on the Hybrid PCS using Energy Storage System for Grid Stabilization.)

  • 이성수;김형준;한기준;조병국;서광덕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.503-505
    • /
    • 2012
  • 본 연구에서는 실증기능 구현을 위해 75KW로 설계된 리튬-폴리머배터리(Lithium Polymer Battery 이하 배터리)와 ESS(Energy Storage System) 내장형 Hybrid-PCS(이하 PCS)을 이용하여 불균일한 풍력 발전원에 대한 Smoothing 제어 및 정출력 제어 대한 연구를 진행 하였다. 잦은 전류 변동으로 인해 발생되는 출력 변동의 안정화를 위해 인버터 전류제어, 벅/부스트 전압제어 기법을 사용하였다. 최적의 Smoothing 제어를 위한 필터 계수 값을 찾기 위한 시험을 진행 하였으며 Energy shift을 위한 정출력 시험도 진행 하였다. 또한 각 제어 모드에서 ESS 중요 파라미터인 SOC(State Of Charge 이하 SOC)변화를 배터리 특성과 관련하여 분석해 보았다.

  • PDF