• Title/Summary/Keyword: Power simulation

검색결과 12,280건 처리시간 0.042초

Simulation of Autonomous Electric Power Market

  • Tezuka, Tetsuo;Kohda, Norio
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2001년도 The Seoul International Simulation Conference
    • /
    • pp.340-345
    • /
    • 2001
  • Electric power market in Japan is now on the trend of deregulation and privatization just like in Europe and the United States. And various approaches for risk management have been investigated taking the electric power price fluctuation after the deregulation into account. The behavior of the investment in power generation plants has not, however, been studied in detail yet due to the complexity of the problem. The problem of the investment in the deregulated power market is that of autonomous decentralized decision-making system, which includes various kinds of decision-makers, that is, power producers called IPPS Each generator has its own criteria for plant investment. Therefore, the total behavior of the decentralized power market will be so complicated, and normative approach will not be applicable fur this analysis. We have developed a simulation-based system fur behavioral analysis and also the framework design of the decentralized power market.

  • PDF

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.

동적 핸드오프와 전력제어를 고려한 적응배열 시스템의 네트워크 시뮬레이션 (System Level Network Simulation of Adaptive Array with Dynamic Handoff and Power Control)

  • Yeong-Jee Chung;Jeffrey H. Reed
    • 한국시뮬레이션학회논문지
    • /
    • 제8권4호
    • /
    • pp.33-51
    • /
    • 1999
  • In this study, the system level network simulation is considered with adaptive array antenna in CDMA mobile communication system. A network simulation framework is implemented based on IS-95A/B system to consider dynamic handoff, system level network behavior, and deploying strategy into the overall CDMA mobile communication network under adaptive array algorithm. Its simulation model, such as vector channel model, adaptive beam forming antenna model, handoff model, and power control model, are described in detail with simulation block. In order to maximize SINR of received signal at antenna, Maximin algorithm is particularly considered, and it is computed at each simulation snap shot with SINR based power control and handoff algorithm. Graphic user interface in this system level network simulator is also implemented to define the simulation environments and to represent simulation results on real mapping system. This paper also shows some features of simulation framework and simulation results.

  • PDF

RTDS-based Model Component Development of a Tri-axial HTS Power Cable and Transient Characteristic Analysis

  • Ha, Sun-Kyoung;Kim, Sung-Kyu;Kim, Jin-Geun;Park, Minwon;Yu, In-Keun;Lee, Sangjin;Kim, Jae-Ho;Sim, Kideok
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2083-2088
    • /
    • 2015
  • The transient characteristics of the tri-axial High Temperature Superconducting (HTS) power cable are different from those of a conventional power cable depending on whether the cable is under a steady or transient state due to the quench. Verification using simulation tools is required to confirm both the characteristics of the cable and the effect of the cable when it is applied to a real utility. However, a component for the cable has not been provided in simulation tools; thus the RTDS-based model component of the tri-axial HTS power cable was developed, and a simulation was performed under the transient state. The considered properties of model component include resistance, reactance and temperature. Simulation results indicate the variation of HTS power cable condition. The results are used for the transient characteristic analysis and stability verification of the tri-axial HTS power cable. In the future, the RTDS-based model component of the cable will be used to implement the hardware-in-the-loop simulation with a protection device.

PHEV 시스템의 분석을 통한 신 PHEV 동력 시스템 제안 (Proposal of a Novel Plug-in-hybrid Power System Based on Analysis of PHEV System)

  • 김진성;박영일
    • 한국자동차공학회논문집
    • /
    • 제23권4호
    • /
    • pp.436-443
    • /
    • 2015
  • In order to develop the PHEV(plug-in hybrid electric vehicle), the specific power transmission systems considering the PHEV system characteristics should be applied. A PHEV applied to series-parallel type hybrid power transmission system is a typical example. In this paper, the novel hybrid power systems are proposed by analyzing the existing PHEV system. The backward simulation program is developed to analyze the fuel efficiency of hybrid power system. Quasi-static models for each components such as engine, motor, battery and vehicle are included in the developed simulation program. To obtain an optimal condition for hybrid systems, an optimization approach called the dynamic programming is applied. The simulation is performed in various driving cycles. A weakness for the existing system is found through the simulation. To compensate for a discovered weakness, novel hybrid power systems are proposed by adding or moving the clutch to the existing system. Comparing the simulation results for each systems, the improved fuel efficiency for proposed systems are verified.

제주 전력계통 2차 전압제어 모델 구축 및 시모의 (Time domain Simulation of a Secondary Voltage Regulation Model to the Jeju Power System)

  • 양병모;송인준;김용학;곽노홍;강지원;장태인;송화창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.469-470
    • /
    • 2007
  • There are many power system simulation software tools for time-domain performance in power system. This paper reports the results of time-domain simulation for the Jeju Power system with a secondary voltage regulation (SVR) model, developed with both TSAT and PSCAD/EMTDC and evaluates them, which are commercial software tools used for digital simulation of power system. TSAT has not been yet verified because of deficient modelling of components in the time domain performance of KEPCO power system. But PSCAD/EMTDC has been enough verified in our system. So, we need to compare and evaluate TSAT with PSCAD/EMTDC in small power system like Jeju. This paper showed that the results simulated by both TSAT and PSCAD/EMTDC is very similar to each other, so TSAT is able to apply for our KEPCO large power system.

  • PDF

Prototype Microgrid의 동특성 모의에 관한 연구 (A Study on Simulation of Dynamic Characteristics in Prototype Microgrid)

  • 최은식;최흥관;전진홍;안종보
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2157-2164
    • /
    • 2010
  • Microgrid is generally defined as cluster of small distributed generators, energy storages and loads. Through monitoring and coordinated control, microgrid can provide various benefits such as reduction of energy cost, peak shaving and power quality improvement. In design stage of microgrid, system dynamic simulation is necessary for optimizing of sizing and siting of DER(distributed energy resources). As number of the system components increases, simulation time will be longer. This problem can restrict optimal design. So we used simplified modeling on energy sources and average switching model on power converters to reduce simulation time. The effectiveness of this method is verified by applying to prototype microgrid system, which is consist of photovoltaic, wind power, diesel engine generators, battery energy storage system and loads installed in laboratory. Simulation by Matlab/Simulink and measurements on prototype microgrid show that the proposed method can reduce simulation time not sacrificing dynamic characteristics.

4MW 에너지저장장치의 전력계통 주파수 조정 운전제어를 위한 실증 (Demonstration to Operate and Control Frequency Regulation of Power System by 4MW Energy Storage System)

  • 임건표;한현규;장병훈;양승권;윤용범
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.169-177
    • /
    • 2014
  • Operation and control system has been installed and tested to use energy storage system(ESS) for frequency regulation at 4MW class of ESS demonstration facility installed at Jeju island, Korea in 2013. Simulation tests were performed by programing language C# for power system of Jeju island to develop control algorithm. Site simulation tests were performed in control system itself without connecting power system and energy storage system. Control algorithm was coded, modified and tested to load to controller and communication system and human-machine interface were developed and tested in the process of simulation tests. After similar results to that of simulation tests by programing language were obtained, power system and energy storage system demonstration facility were connected to control system by communication system. Energy storage system for frequency regulation was tested for actual frequency and simulation frequency. The site tests showed the similar results to that of simulation tests and the control systems is possible to be operated for frequency regulation. Faster response of energy storage system for frequency regulation, less costs and less capacity of energy storage systems which cover for frequency regulation of power plants. It is expected that more studies for time-reduction and time-delay elements can make less capacity of energy storage system cover more role of frequency regulation of power plants.

UPFC의 동적 성능해석을 위한 시뮬레이션 모형 (Simulation Model for Dynamic Performance Analysis of UPFC)

  • 한병문;최대길;신익상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.479-481
    • /
    • 1996
  • This paper describes a simulation model to analyze the dynamic performance of Unified Power Flow Controller which ran flexibly adjust the active and reactive power flow through the ac transmission line. An equivalent circuit to analyze the basic principle for the whole system operation was developed and a control system for the Unified Power Flow Controller was derived using vector control method. A computer simulation model with EMTP code was also conceived to evaluate the performance of the Unified power Flow Controller. The simulation results show that Unified Power flow Controller is very effective for controlling the power flow and damping the subsynchronous resonance in the power system.

  • PDF

Development of Wind Turbine Simulation System Based on IEC 61400-25 Standard

  • Lee, Jae-Kyung;Kim, Dong-Wook;Kim, Seok-Tae;Chae, Chang-Hun;Park, Joon-Young
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.349-359
    • /
    • 2019
  • This paper introduces a wind turbine simulation system based on the IEC 61400-25 standard to simulate different kinds of wind turbines. A unified communication protocol was required for monitoring and control of wind turbines, because manufacturers had used their own protocols for their turbines. As a result of such an effort, the international standard IEC 61400-25 was established. To implement the schema of IEC 61400-25, the IEC61850 SCL was modified and applied to the simulation system, which enabled the system to be compatible with heterogeneous wind turbine information models. The developed simulation system can be used for interoperability tests with a new type of wind turbine information model.