• 제목/요약/키워드: Power signals

검색결과 2,329건 처리시간 0.027초

주기적 등척성 수축에서의 국소근육피로 측정을 통한 피로지수의 개발 (Development of a Fatigue Index Based on the Measurement of Localized Muscular Fatigue During the Cyclic Isometric Contraction)

  • 정소라;정민근
    • 대한산업공학회지
    • /
    • 제19권4호
    • /
    • pp.87-96
    • /
    • 1993
  • Spectrum analysis of surface electromyogram (FMG) signals is an effective approach to the study of localized muscular fatigue during isometric contraction. Many investigators have con firmed the frequency of the EMG signals being lowered during sustained contaction. In this study, the cyclic loading tasks were performed, and a comparison was made for the median power frequency shift pattern of the EMG signals with the sustained contraction of the same load. The median power frequency shift of the EMG signals for the cyclic loading task was found to be a part of that for the sustained contraction. Based on this result, a new muscle fatigue index was computed by normalizing the duration of the sustained contraction. A fatigue index was obtained as a function of exertion level and the work/rest schedule. With the proposed fatigue index, it is possible to evaluate or predict the degree of muscular fatigue for a physically demanding task.

  • PDF

신경회로망을 이용한 과도파형의 기본파성분 추출에 관한 연구 (A Study on the Extraction of Fundamental Frequency Components in the Transient Wave Signals Using Artificial neural networks)

  • 신명철;이복구
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.553-563
    • /
    • 1994
  • This paper presents a filtering method using neural networks to extract fundamental frequency components of the transient wave signals in power systems. Based on the ability of multilayer feedforward neural networks to approximate any continuous function, a neural networks mapping filter is proposed for the protective distance relaying systems to extract the effective components efficiently. A characteristic feature of this mapping filter is composed of the multilayer perceptron neural networks which are trained by using random signals and those are mapped to the DFT filtering computational structure by GDR(Generalized Delta Rule). The advantage of this approach is demonstrated by the random waves and the fault transient wave signals of EMTP(electromagnetic transients program) in power systems fault conditions. The proposed method is compared with the conventional method and the simulation results show the efficiency of the neural networks.

  • PDF

Reducing PAPR of SC-FDMA Signals through Simple Amplitude Predistortion

  • Xia, Yujie;Ji, Jinwei
    • ETRI Journal
    • /
    • 제37권5호
    • /
    • pp.922-928
    • /
    • 2015
  • A novel peak-to-average power ratio (PAPR) reduction method is proposed for single-carrier frequency-division multiple access (SC-FDMA) signals. The proposed method deliberately distorts the amplitude values of a few of the complex modulated symbols that cause peaks beyond a predetermined threshold in the samples of the output signal. The method then marks the location indices of the distorted symbols by using a pilot block at the transmitter without transmitting side information. At the receiver, the method is then able to recover the distorted amplitude values through the marked location indices. Computer simulation results show that when compared to conventional SC-FDMA signals, the proposed scheme can effectively reduce the PAPR of SC-FDMA signals with asymptotically consistent bit error rate (BER) performance.

전기전자 기기의 노이즈 패턴 분석에 의한 노이즈 개선 대책 (Noise Improvement Countermeasure by Noise Pattern Analysis for Electrical and Electronic Equipment)

  • 조대훈;이기식
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.194-202
    • /
    • 2017
  • In this study, we measured and analyzed electrical noise signals present in devices and systems operated in industrial facilities. Based on the analytic findings, we studied the most effective improvement measures for eliminating such noise signals. Leakage current and ground current generate data interferences in communication systems, and therefore we measured leakage current and ground current. We also measured and analyzed electrical noises in power systems to predict noise pathways and interference routes. Furthermore, we proposed the most effective and reliable improvement measures for blocking off various noise signals and safely eliminating them by improving the internal wiring of the facilities and grounding systems. As a final step, we conducted the proposed improvement measures and confirmed that they helped to improve the operations of the device sand systems in service by re-measuring electrical noise signals and comparing them with those measured before the proposed improvement measures were implemented.

UHF이중대역법을 이용한 GISPD분석 (GISPD Analysis Using UHF Dual-Band Method)

  • 김광화;이상화;최재구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1860-1862
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High band to Full band increases with gas pressure.

  • PDF

Study of PD Location in Generators by PD Pulses Propagation

  • Cheng, Yang-Chun;Li, Cheng-Rong;Wang, Wei
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.252-256
    • /
    • 2006
  • When a partial discharge takes place at the stator of a generator, the electrical pulse will propagate along the stator bars and the capacitor chains formed by the end part of the stator winds. On the first path, the pulse propagates as a travel wave at slow speed. On the second path, the pulse propagates at quick speed. Based on the data of the experiments on a real 50 MW steam generator, the author has found the pulses can propagate by magnetic field of the stator winding. It was studied that how to locating the partial discharge by signals coming from the different paths, including the features of signals on the two paths at time domain and frequency domain, the measurement frequency rang of the signals, the blind area, the advantage and disadvantage of this method.

웨이블릿 해석과 인공 신경회로망을 이용한 원자력발전소의 급수유량 평가 (Feedwater Flow Rate Evaluation of Nuclear Power Plants Using Wavelet Analysis and Artificial Neural Networks)

  • 유성식;서종태;박종호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.346-353
    • /
    • 2002
  • The steam generator feedwater flow rate in a nuclear power plant was estimated by means of artificial neural networks with the wavelet analysis for enhanced information extraction. The fouling of venturi meters, used for steam generator feedwater flow rate in pressurized water reactors, may result in unnecessary plant power derating. The backpropagation network was used to generate models of signals for a pressurized water reactor. Multiple-input single-output heteroassociative networks were used for evaluating the feedwater flow rate as a function of a set of related variables. The wavelet was used as a low pass filter eliminating the noise from the raw signals. The results have shown that possible fouling of venturi can be detected by neural networks, and the feedwater flow rate can be predicted as an alternative to existing methods. The research has also indicated that the decomposition of signals by wavelet transform is a powerful approach to signal analysis for denoising.

  • PDF

주파수 영역 등화기를 사용하는 단일 반송파 전송 시스템을 위한 저 전력 전송 기법 (Low Power Transmission Technique for Single-Carrier Modulation with Frequency Domain Equalization)

  • 정혁구
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.247-251
    • /
    • 2017
  • This paper proposes a low power transmission technique for single-carrier modulation with frequency domain equalization. As time domain signals and frequency domain signals have unique corresponding functions, inserting zeros after each symbol causes a repetition in other domain, so maximal ratio combining technique using repetitive transmission can be applied in the frequency domain. In this paper, we configure transmit signals to insert zeros after each symbols for single-carrier modulation with frequency domain equalization and maximal ratio receive combining block in the receiver structures, propose a structure for transmitter and receiver and show that its performance is better than the traditional algorithm by simulations.

연삭 동력신호를 응용한 결함진단에 관한 연구 (A Study on the Fault Diagnosis Applied to the Grinding Power Signals)

  • 곽재섭
    • 한국생산제조학회지
    • /
    • 제9권4호
    • /
    • pp.108-116
    • /
    • 2000
  • Undesired trouble such as chatter vibration and burning on the ground surface appears frequently in the cylindrical plunge grinding process. Establishment of a credible fault diagnostic system for the grinding process is the major purpose of this study. Power signals generated during the grinding operation were sampled and analyzed to determine the relationship between grinding troubles and behavior of signal changes. In addition, a neural network was optimized with a momentum coefficient a learning rate, and a structure of the hidden layer through the iterative learning process. Based on the established system, success rates of the trouble recognition were verified.

  • PDF

시간지연을 가진 발전소 제어시스템의 자동동조를 위한 System identification 방법 (System identification method for the auto-tuning of power plant control system with time delay)

  • 윤명현;신창훈;박익수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1008-1011
    • /
    • 1996
  • Most control systems of power plants are using classical PID controllers for their process control. In order to get the desired control performances, the correct tuning of PID controllers is very important. Sometimes, it is necessary to retune PID controllers after the change of system operating condition and system design change, etc. Commercial auto-tuning controllers such as relay feedback controller can be used for this purpose. However, using these controllers to the safety-critical systems of nuclear power plants may be cause of unsafe operation, because they are using test signals for tuning. A new system identification auto-tuning method without using test signal has been developed in this paper. This method uses process input/output signals for system identification of unknown control process. From the model information of control process which was obtained from system identification approach, the optimal PID parameters can be calculated. The method can be used in the safety-critical systems because it is not using test signals during system modeling process.

  • PDF