• 제목/요약/키워드: Power sharing control

검색결과 259건 처리시간 0.025초

Fuzzy PID Controller for Accurate Power Sharing in DC Microgrid

  • Nguyen, Duy-Long;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.115-117
    • /
    • 2019
  • In this paper, an intelligent control scheme based on Fuzzy PID controller is proposed for accurate power sharing in DC Microgrid. The proposed Fuzzy PID controller is designed with the aid of a closed loop control based on per unit power of each distributed generator (DG), and accurate power sharing is successfully realized in proportional to each DG's power rating regardless of the line resistance difference or the load change. Thanks to Fuzzy PID controller, the dynamic response becomes faster and the stability of the microgrid system are improved in comparison to conventional PID controller. The superiority of the proposed method is analyzed and verified by simulation in Matlab and Simulink.

  • PDF

발전제어시스템에 적용 가능한 사이버 보안 정보공유 모델 연구 (A Study on Cyber Security Information Sharing Model Applicable to Power Generation Control System)

  • 민호기;이중희
    • 정보보호학회논문지
    • /
    • 제34권3호
    • /
    • pp.463-478
    • /
    • 2024
  • 발전제어시스템의 보안 취약점 개선을 위한 선행 연구의 한계점을 분석하고 그 대안으로 사이버 보안 정보공유모델을 제안하였다. 발전제어시스템의 운영 특성을 파악하고 사이버 보안 정보공유 개념과 정책, 실제 구현사례들을 분석하여 발전제어시스템에 효과적으로 적용할 수 있는 정책과 기술방안을 제시하고 모델평가를 시행하였다.

Low-Voltage and High-Current DC Output Realized by Multiple Power Cells Based on Deadbeat and Automatic Current Sharing Control

  • Liu, Jinfeng;Zhang, Yu;Wang, Xudong;IU, Herbert Ho-Ching
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1575-1585
    • /
    • 2017
  • This paper presents a synchronous generator with a distributed system of multiple parallel three-phase power cells. This generator can immediately output high DC. Each power cell comprises three-phase windings and a three-phase synchronous rectification bridge with a deadbeat control of load power feedforward, which can improve the characteristics of dynamic response and reflect the load variance in real time. Furthermore, each power cell works well independently and modularly using the method of automatic maximum current sharing. The simulation and experimental results for the distributed controller of multiple power cells demonstrate that the deadbeat control method can respond quickly and optimize the quality of the energy. Meanwhile, automatic maximum current sharing can realize the validity of current sharing among power cells.

An Enhanced PCC Harmonic Voltage Mitigation and Reactive Power Sharing in Islanded Microgrid

  • Pham, Minh-Duc;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.138-140
    • /
    • 2018
  • Parallel distributed generators (DGs) in the islanded microgrid are generally operated autonomously by means of the droop control scheme. However, the traditional droop control methods which use the P-${\omega}$ and Q-E curve to share power between DGs are still concerned to improve the accuracy of reactive power sharing. Moreover, the uncontrolled harmonic power reduces the point of common coupling (PCC) voltage quality and microgrid stability. In order to solve these problems, this paper proposes an enhanced PCC harmonic control strategy and an improved reactive power sharing control scheme. Based on the low bandwidth communications, a secondary control is implemented with both central controller and local controller. The effectiveness of the proposed control scheme is analyzed through the simulation.

  • PDF

Enhanced Reactive Power Sharing and Voltage Restoration in Islanded Microgrid

  • Pham, Minh-Duc;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.47-48
    • /
    • 2016
  • Parallel distributed generators (DGs) in the islanded micro-grid are normally controlled with the aid of the droop control scheme. However, the traditional droop control methods which use the P-${\omega}$ and Q-E curve to share power between DGs are still concerned to improve the accurate of reactive power sharing and variation of frequency and voltage at the point of common coupling (PCC). This paper proposes a control scheme to solve the limitation of microgrid in islanded operation such as reactive power sharing accuracy and PCC voltage and frequency restoring. In order to achieve the control objective, a secondary control is implemented with both central controller and local controller by using the low bandwidth communications. The effectiveness of the proposed control scheme is analyzed through the simulation.

  • PDF

Cooperative Power Control Scheme for a Spectrum Sharing System

  • Ban, Tae-Won;Jung, Bang-Chul
    • Journal of information and communication convergence engineering
    • /
    • 제9권6호
    • /
    • pp.641-646
    • /
    • 2011
  • In this paper, we investigate a power control problem which is very critical in underlay-based spectrum sharing systems. Although an underlay-based spectrum sharing system is more efficient compared to an overlay-based spectrum sharing system in terms of spectral utilization, some practical problems obstruct its commercialization. One of them is a real-time-based power adaptation of secondary transmitters. In the underlay-based spectrum sharing system, it is essential to adapt secondary user's transmit power to interference channel states to secure primary users' communication. Thus, we propose a practical power control scheme for secondary transmitters. The feedback overhead of our proposed scheme is insignificant because it requires one-bit signaling, while the optimal power control scheme requires the perfect information of channel states. In addition, the proposed scheme is robust to feedback delay. We compare the performance of the optimal and proposed schemes in terms of primary user's outage probability and secondary user's throughput. Our simulation results show that the proposed scheme is almost optimal in terms of both primary user's outage probability and secondary user's throughput when the secondary user's transmit power is low. As the secondary user's transmit power increases, the primary user's outage probability of the proposed scheme is degraded compared with the optimal scheme while the secondary user's throughput still approaches that of the optimal scheme. If the feedback delay is considered, however, the proposed scheme approaches the optimal scheme in terms of both the primary user's outage probability and secondary user's throughput regardless of the secondary user's transmit power.

Improved Reactive Power Sharing and Harmonic Voltage Compensation in Islanded Microgrids Using Resistive-Capacitive Virtual Impedance

  • Pham, Minh-Duc;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1575-1581
    • /
    • 2019
  • Due to the mismatched line impedance among distributed generation units (DGs) and uncontrolled harmonic current, the droop controller has a number of problems such as inaccurate reactive power sharing and voltage distortion at the point of common coupling (PCC). To solve these problems, this paper proposes a resistive-capacitive virtual impedance control method. The proposed control method modifies the DG output impedance at the fundamental and harmonic frequencies to compensate the mismatched line impedance among DGs and to regulate the harmonic current. Finally, reactive power sharing is accurately achieved, and the PCC voltage distortion is compensated. In addition, adaptively controlling the virtual impedance guarantees compensation performance in spite of load changes. The effectiveness of the proposed control method was verified by experimental results.

마이크로그리드 독립 운전 모드시 저전압 불평형 선로 임피던스를 고려한 드룹 방식의 인버터 병렬 운전 제어 연구 (Droop Control for Parallel Inverers in Islanded Microgrid Considering Unbalanced Low-Voltage Line Impedances)

  • 임경배;최재호
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.387-396
    • /
    • 2013
  • This paper investigates the droop control of parallel inverters for an islanded mode of microgrid. Frequency and voltage droop control is one of power control and load demand sharing methods. However, although the active power is properly shared, the reactive power sharing is inaccurate with conventional method due to the unequal line impedances and the power coupling of active - reactive power. In order to solve this problem, an improved droop method with virtual inductor concept and a voltage and current controller properly designed have been considered and analyzed through the PSiM simulation. The performance of improved droop method is analyzed in not only low-voltage line but also medium voltage line.

Improved Reactive Power Sharing for Parallel-operated Inverters in Islanded Microgrids

  • Issa, Walid;Sharkh, Suleiman;Mallick, Tapas;Abusara, Mohammad
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1152-1162
    • /
    • 2016
  • The unequal impedances of the interconnecting cables between paralleled inverters in the island mode of microgrids cause inaccurate reactive power sharing when the traditional droop control is used. Many studies in the literature adopt low speed communications between the inverters and the central control unit to overcome this problem. However, the losses of this communication link can be very detrimental to the performance of the controller. This paper proposes an improved reactive power-sharing control method. It employs infrequent measurements of the voltage at the point of common coupling (PCC) to estimate the output impedance between the inverters and the PCC and then readjust the voltage droop controller gains accordingly. The controller then reverts to being a traditional droop controller using the newly calculated gains. This increases the immunity of the controller against any losses in the communication links between the central control unit and the inverters. The capability of the proposed control method has been demonstrated by simulation and experimental results using a laboratory scale microgrid.

다른 정격용량을 가진 3상 UPS 시스템의 병렬운전을 위한 주종제어 기법 (A Master and Slave Control Strategy for Parallel Operation of Three-Phase UPS Systems with Different Ratings)

  • 이우철;현동석
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.341-349
    • /
    • 2004
  • 본 논문에서는 전체 시스템의 용량 증대와 부하 중요도에 따른 신뢰성 향상을 위해 사용되는 UPS 병렬 운전시 발생하는 문제점을 해석하고, 이를 해결하기 위해 기존에 연구되어온 다양한 제어기법들을 조사하였다. 또한 기존의 연구방법에서 적용할 수 없었던 다른 정격의 병력 운전 적용시 L, C 출력필터에 의한 문제점을 해결하기 위해 주종 제어를 이용한 3상 UPS의 전류 분달 제어기법이 연구되었다. 제안된 제어 알고리즘의 타당성을 검증하기 위해 시뮬레이션 및 실험을 수행하였다.