• 제목/요약/키워드: Power quality measurement

검색결과 349건 처리시간 0.027초

특고압 수용가의 전력품질 측정 및 분석 (Power Quality Measurement and Analysis of Extra-High Voltage Customer)

  • 조재형;이종필;지평식
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.286-290
    • /
    • 2015
  • Power system is composed of a number of power devices and equipment. This factor affects the power quality is also displayed very complicated and varied. The accurate measurement and analysis of the causes of power quality problems is difficult. In preparing for these issues, there are many difficulties. In this study, Power quality of A public establishment of Chungbuk province were measured and analyzed. Measurement results of the fifth harmonic current was very large. Accordingly, the harmonic reduction will be needed. This research will be utilized as fundamental data to improve power quality for power utility and customer.

U57 풍력발전기 전력품질 실증연구 (Study of Power Quality Measurement U57 Windturbine)

  • 이병철;박희철;황진수;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.310-314
    • /
    • 2008
  • The exploitation of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and it is important to respect and to deal with the impact of wind turbine. This paper addresses the power quality characteristics of U57 Wind Turbine. 750kW gearless type wind turbine for low wind speed, named U57, is developed by UNISON. The power quality measurement system consists of measuring WTG output current, line-to line voltage and wind speed signal. With using measured data, power quality measurement is evaluated about maximum power, reactive power, voltage fluctuation, harmonics according to IEC 61400-21.

  • PDF

비선형 부하에 적용 가능한 전력 계측 회로의 개발 (The Development of Power Measurement Circuit for Non-Linear Load)

  • 박종찬;김병진;김수곤;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.79-82
    • /
    • 2002
  • Non-linear loads are the sources of power systems harmonics, and the power quality is influenced by harmonics, Recently, the requirements of power quality is important. For the power quality problems. it is very important that the development of power measurement circuit for non-linear load. In this paper, it is discoursed on that high speed sampling circuit and efficient power analysis algorithms. The sampling circuit is implemented using FPGA. Since the power measurement circuit system is composed by FPGA and efficient power algorithms. it is practicable application that accurate power measurement, stable protection relaying, and low cost system configuring.

  • PDF

Digital Signal Processor를 이용한 실시간 전력 요소와 왜율 측정 시스템 설계 (System Design for Real-Time Measuring of Power Quality and Harmonics Distortion using Digital Signal Processor)

  • 김근준;강봉순
    • 한국정보통신학회논문지
    • /
    • 제20권7호
    • /
    • pp.1283-1289
    • /
    • 2016
  • 전력은 현대 사회를 구성하는데 있어 필수적인 자원이다. 최근, 전력에 대한 수요가 급격하게 증가하였으며 전력 수요 증가는 전력 품질의 저하를 야기하였다. 현대 사회에서 전력 품질은 일반 가정과 산업 전반에 걸쳐 큰 문제를 일으킬 수 있는 중요한 요소가 되었다. 전력 품질 문제를 예방하기 위해서는 전력 품질에 대한 계측과 초기 대응이 중요하다. 본 논문에서는 실시간으로 전력 품질을 계측하고 고조파를 분석하여 모니터링 할 수 있는 시스템 제안한다. 마이크로칩의 dsPIC33FJ256GP710A칩을 이용한 DM240001보드를 이용하여 최대 3상 3선에 해당하는 배선 방식의 전력 품질을 계측하는 시스템을 설계하였고, 계측 알고리즘의 최적화로 전력 품질의 순간적인 변화를 측정할 수 있도록 하였다. 또한, 최대 31차에 해당하는 고조파들에 대하여 전압과 전류의 왜율과 수요 전류 왜율에 대해서도 측정 가능하도록 설계하였다.

개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가 (Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System)

  • 김근준;강봉순
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.619-623
    • /
    • 2018
  • 사회의 발달로 인하여 전력에 대한 수요가 증가함과 동시에 전력의 품질 관리가 중요한 문제로 부상하였다. 이러한 전력관리를 효율적으로 수행하기 위하여 본 논문에서는 다선로 전력 계측을 위한 DSP 기반 전력 측정 시스템을 제안한다. 종래의 전력 계측 시스템이 하나의 선로의 전력만을 측정 할 수 있었기 때문에, 개별 선로에 대한 전력 품질 측정을 위해서는 선로마다 전력 품질 측정 장치가 필요로 하였으며 이는 비용적인 문제로 인하여 시스템의 실제 구현이 불가능한 구조였다. 본 논문에서 제안하는 시스템은 디지털 신호 처리 알고리즘을 이용하여 최대 12개소의 전력 품질을 실시간 계측 할 수 있는 시스템을 제안하며, 이를 토대로 한 시제품을 한국전기연구원의 공인시험 성적서를 통하여 그 성능을 평가 받았다. 성능 시험결과 정밀 계측의 오차 범위 ${\pm}0.3%$의 우수한 성능임을 평가 받았다.

계통 연계형 태양광 발전시스템의 전력품질에 관한 연구 (A Study on the Power Quality of the Grid connected Photovoltaic Power System)

  • 최형범;김경철;황영록
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.88-98
    • /
    • 2011
  • Development and use of renewable energy due to environmental problems and depletion of energy affect grid-connected power system around the world. Therefore this paper analyzes the characteristic of gird connected photovoltaic power generation system which it is available to connect the utility. Renewable energy photovoltaic power system has been linked to the system to analyze the impact of photovoltaic system. MATLAB / Simulink program is modeled and analyzed on power quality of a photovoltaic power plant. It is measured that power data for the Grid connected photovoltaic power plant with instantaneous measuring, 3sec measuring, 10min measuring for 7 days. Harmonic field measurement have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. so, it is used 50[%] cumulative probability approach. This paper provides an in depth analysis on power quality field measurement of the Grid connected photovoltaic power plant.

LED 기반 그린에너지 조명시스템을 위한 전력품질 측정 (Power Quality Measurement for LED-based Green Energy Lighting Systems)

  • 유형모;최진원;최상호
    • 전자공학회논문지
    • /
    • 제50권2호
    • /
    • pp.174-184
    • /
    • 2013
  • LED 기반 그린에너지 조명 시스템의 성공적인 연구 개발과 원만한 설치 운영을 위해서는 펄스 파, 스파이크 파를 비롯한 비선형신호와 고조파, sag, swell 등을 포함한 불요신호에 대한 실시간 전력품질측정이 요구된다. 본 논문에서는 그린에너지 조명시스템 응용을 타깃으로 기존 저주파수 대 (60Hz~수KHz)는 물론 수십 KHz 이상의 고주파수 대에 발생하는 각종 전원 신호 분석이 가능한 저가형 전력품질측정 (power quality measurement: PQM) 방안을 제안하고, 이를 TI 320F28335 MCU(micro-controller unit) 기반 PQM 테스트 베드로 구현한다. 제안된 알고리즘은 CCS (Code Composer Studio) 3.3 환경에서 C언어로 작성하였으며, 임의 신호 발생기(NF-WF1974)로부터 발생된 모의 신호를 활용하여 구현된 알고리즘을 검증한다. 테스트 베드를 이용하여 LED SMPS로부터 발생되는 각종 비선형 전류 신호 측정, FFT를 이용한 고조파 신호의 분석이 가능할 뿐 아니라 이산 웨이블렛 변환을 이용한 sag, swell, interruption 등의 고품질 전력신호 측정도 가능하다.

계통연계 풍력발전기의 전력품질 평가를 위한 IEC 61400-21 표준 실시간 계측 장치 구현 (An Implementation of Real-time Measurement and Assessment System for Power Quality Characteristics of Grid Connected Wind Turbines)

  • 이종주;김동준;문영환
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1560-1565
    • /
    • 2010
  • The renewable resource are getting more attentions with increased concerns on the depletion of fossil fuels and several environmental issues like emission problem. Wind power is a representative option among several renewable sources and the generation capacity using wind power is being increased. However, the wind generation is so volatile on its output characteristic, so it is required to assess the grid impact of wind power generation by measuring the fluctuation effect more precisely. This paper proposes the method for measuring the generation output according to IEC 61400-21(Measurement and assessment of power quality characteristics of grid connected wind turbines) to assess the power quality of wind turbine generation. In addition, it shows an application case to a small-scale wind power generator. In the case study, it suggests a structure design of the proposed measurement instrument both on hardware and software aspects, which is composed of a remote monitoring & data analysis program and an FPGA based real-time signal processing device.

TMS320C6701 프로세서를 이용한 전력 품질 측정 (Power Quality Measurement Using TMS320C6701 Processor)

  • 신명준;손영익;김갑일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.50-52
    • /
    • 2005
  • Research interests in PQ(Power Quality) measurement and monitoring system have been increased. This paper describes an experimental result for monitoring system that monitors power quality and undesirable accidents when distributed generations are connected to the power grid. Prior to develop a physical monitoring system for distributed generation applications, we constitute a mesuring system for the general PQ factors. In this paper, an approach to how to measure the PQ elements is presented by using TMS320C6701 processor. Simulation results using the PSCAD and the power system simulation equipment Dobel have verified the proposed measurement system.

  • PDF

IEC 기준에 따른 풍력터빈 전기품질 측정절차 수립에 관한 연구 (Studying power quality measurement procedures of wind turbines according to IEC standard)

  • 서정출;윤기갑;정원욱;채우규;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1197-1198
    • /
    • 2006
  • The wind turbine system, one of the distributed resource, has a large effect on the distribution system. because windfarm is located in the end part of the distribution system, the hilly section and the shore, which is easy to obtain the wind energy, it is difficult to manage the voltage and the power quality. Therefore this paper deals with the measurement and assessment of power quality characteristic of wind turbines with IEC 61400-21.

  • PDF