• 제목/요약/키워드: Power oscillation

Search Result 541, Processing Time 0.029 seconds

Analysis of the Factors Affecting Low-Frequency Oscillations in KEPCO Power System` With Pumped-Storage Plant (한전 전력계통의 저주파 진동현상 요인분석;양수발전기 기동시)

  • Kil Yeong Song;Sae Hyuk Kwon;Kyu Min Ro;Seok Ha Song
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.841-849
    • /
    • 1992
  • In power system operation, the stability of synchronous machine has been recognized one of the most important things. AESOPS program developed by EPRI in U.S.A. is a frequency domain analysis program in power system stability and it computes the electro-mechanical oscillation mode. This paper presents how to analyze the power system small signal stability problem efficiently by uusing the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO power system of 1986 with pumped-storage plant. To reduce the computing time and efforts, selecting the poorly-damped oscillation mode and clustering technique have been used. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been improved.

  • PDF

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

An Antenna-Integrated Oscillator Design Providing Convenient Control over the Operating Frequency and Output Power (동작주파수 및 출력파워 조절이 용이한 신호생성용 안테나 설계)

  • Lee, Dong-Ho;Lee, Jong-In;Kim, Mun-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • A new design for easily controlling operating frequency of an antenna-integrated planar oscillator is introduced. The oscillator circuit of a broadband negative-resistance active part and a passive load including a patch antenna. The patch resonance is used for determining the oscillation frequency. This design reduces the possibility of mismatch between antenna radiation and oscillation frequencies. To achieve optimum output power, load-pull simulation for the negative-resistance circuit is used. The load-pull simulation shows the feed point and the delay of feed line can affect the oscillation power. Two negative-resistance circuits capable of supporting oscillation over full C-band and X-band are fabricated. The oscillation frequency, output power and phase noise for different patch antennas are measured.

  • PDF

Filter Calibration using Self Oscillation of Biquad RC Filter (바이쿼드 RC 필터의 자가 발진을 이용한 필터 교정)

  • Ahn, Deok-Ki;Hwang, In-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.1005-1009
    • /
    • 2010
  • This paper presents a digitally-controlled filter calibration technique for biquad RC filter using self oscillation. The biquad RC filter is converted to a fully-differential ring oscillator by changing its resistor connections, where the oscillation frequency reflects the cut-off frequency. The proposed calibration circuit measures the oscillation frequency by counting with a fixed higher-frequency clock and then tunes it to a desired frequency with a digital frequency-locked loop including a PI controller. Because the proposed circuit directly measures the cut-off frequency of the filter itself and calibrates it with the small area digital circuits, the area and the power consumption are much small compared with conventional works. When it is implemented in a 65nm CMOS process, the calibration circuit except the filter consumes the area of 80um X 50um and power consumption is 443uA at 1.2 V supply voltage.

Active Short Circuit Control Method to Reduce Overcurrent and Oscillation Current in PMSM (영구자석 동기모터 진동 및 과전류 저감을 위한 능동단락회로 제어 기법)

  • Choi, Jong-Won;Kim, Yoon-Jae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.339-347
    • /
    • 2022
  • This study proposes the mitigation method for overcurrent and oscillation motor current in an active short-circuit operation. This operation is attracting attention as the safe state of electric vehicle traction inverters. However, the active short-circuit operation generates oscillation and overcurrent of motor currents during a transient state. The proposed method uses two different safe states in PMSM, such as active short circuit and freewheeling. The active short circuit is used for safe state in a steady state. To reduce the overshoot and oscillation, a freewheeling state is injected between active short-circuit operation by comparing the motor phase current with an analytically calculated steady-state motor current. Freewheeling state is only used in a transient state. The performance is demonstrated through simulations and experimental results. The peak current of the motor was reduced from 52 A to 40 A, and oscillation time was reduced.

A Study of High Power Microwave Output by K-band Waveguide (K-band 도파관을 이용한 대전력 마이크로파 출력장치 연구)

  • Kim, Won-Sop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.588-591
    • /
    • 2009
  • We had experimental studies of microwave output generator. We experimented with a corrugate-shped K-band slow wave guide in the backward wave oscillator. It generated output 표 interaction between electron beam's generation and magnetic field. We estimated oscillation frequency at 24GHz by changing propagation velocity and group velocity. We identified movement by second harmonic of Cherencov interaction and slow cyclotron mode. In our study we achieved oscillation stabilization, generation of long pulse, improvement of oscillation efficiency and output.

Analysis of Global Oscillation via Sync Search in Power Systems (전력계통에서 동조탐색과 광역진동해석)

  • Shim, Kwan-Shik;Nam, Hae-Kon;Kim, Yong-Gu;Moon, Young-Hoan;Kim, Sang-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1255-1262
    • /
    • 2009
  • The present study explained the phenomenon that low frequency oscillation is synchronized with discrete data obtained from a wide area system, and a sync search method. When a disturbance occurs in an power system, various controllers operate in order to maintain synchronization. If the system's damping is poor, low frequency oscillations continue for a long time and the oscillations are synchronized with one another at specific frequency. The present study estimated dominant modes, magnitude and phase of signals by applying parameter estimation methods to discrete signals obtained from an power system, and performed sync search among wide area signals by comparing the estimated data. Sync search was performed by selecting those with the same frequency and damping constant from dominant oscillation modes included in a large number of signals, and comparing their magnitude and phase. In addition, we defined sync indexes in order to indicate the degree of sync between areas in a wide area system. Furthermore, we proposed a wide area sync search method by normalizing mode magnitude in discrete data obtained from critical generator of the wide area. By applying the sync search method and sync indexes proposed in this study to two area systems, we demonstrated that sync scanning can be performed for discrete signals obtained from power systems.

A Parameter Estimation of Time Signal and Analysis of Low Frequency Oscillation in Power Systems (시간영역에서 파라미터 추정과 전력계통의 저주파진동 해석)

  • Shim Kwan-Shik;Nam Hae-Kon;Kim Yong-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.3
    • /
    • pp.122-132
    • /
    • 2005
  • This paper presents a novel approach based on Prony method to analysis of small signal stability in power system. Prony method is a valuable tool in identifying transfer function and estimating the modal parameter of power system oscillation from measured or computed discrete time signal. This paper define the relative residue of time signal and propose the condition to select low frequency oscillation in each generator. This paper describes the application results of proposed algorithm with respect to KEPCO systems. Simulation results show that the proposed algorithm can be used as another tools of power systems analysis.

Identification of Power System Oscillation Using DFT Algorithm (DFT 알고리즘을 이용한 전력계통 동요모드 확인)

  • Kim, Dong-Joon;Moon, Young-Hwan;Kim, Yong-Hak;Yoon, Yong-Beum
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.5
    • /
    • pp.218-224
    • /
    • 2001
  • This paper describes the identification of torsional modes and power oscillation modes including the inter-area modes and local modes of KEPCO using the proposed DFT analysis algorithm which is applied to the digitally recorded RMS values of power system variables such as steady-state measured active power, load angle and so on. As a result, the inter-area mode of 0.65Hz and the local modes of the three different generators were identified. In addition the torsional modes of two steam-turbo generators were analyzed by applying the DFT algorithm. Thus, this paper clearly shows the availability of the proposed DFT algorithm that can analyze the digitally recorded effective values measured from the equipment such as PMU of DSM.

  • PDF

Unstable Operation of Francis Pump-Turbine at Runaway: Rigid and Elastic Water Column Oscillation Modes

  • Nicolet, Christophe;Alligne, Sebastien;Kawkabani, Basile;Simond, Jean-Jacques;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.324-333
    • /
    • 2009
  • This paper presents a numerical simulation study of the transient behavior of a $2{\times}340MW$ pump-turbine power plant, where the results show an unstable behavior at runaway. First, the modeling of hydraulic components based on equivalent schemes is presented. Then, the 2 pump-turbine test case is presented. The transient behavior of the power plant is simulated for a case of emergency shutdown with servomotor failure on Unit 1. Unstable operation at runaway with a period of 15 seconds is properly simulated using a 1-dimensional approach. The simulation results points out a switch after 200 seconds of the unstable behavior between a period of oscillations initially of 15 seconds to a period of oscillation of 2.16 seconds corresponding to the hydraulic circuit first natural period. The pressure fluctuations related to both the rigid and elastic water column mode are presented for oscillation mode characterization. This phenomenon is described as a switch between a rigid and an elastic water column oscillation mode. The influence of the rotating inertia on the switch phenomenon is investigated through a parametric study.